{"title":"通过聆听准确度、主观聆听努力程度和功能性近红外光谱测定助听器的益处。","authors":"Jonathan M Vaisberg, Sean Gilmore, Jinyu Qian, Frank A Russo","doi":"10.1177/23312165241273346","DOIUrl":null,"url":null,"abstract":"<p><p>There is broad consensus that listening effort is an important outcome for measuring hearing performance. However, there remains debate on the best ways to measure listening effort. This study sought to measure neural correlates of listening effort using functional near-infrared spectroscopy (fNIRS) in experienced adult hearing aid users. The study evaluated impacts of amplification and signal-to-noise ratio (SNR) on cerebral blood oxygenation, with the expectation that easier listening conditions would be associated with less oxygenation in the prefrontal cortex. Thirty experienced adult hearing aid users repeated sentence-final words from low-context Revised Speech Perception in Noise Test sentences. Participants repeated words at a hard SNR (individual SNR-50) or easy SNR (individual SNR-50 + 10 dB), while wearing hearing aids fit to prescriptive targets or without wearing hearing aids. In addition to assessing listening accuracy and subjective listening effort, prefrontal blood oxygenation was measured using fNIRS. As expected, easier listening conditions (i.e., easy SNR, with hearing aids) led to better listening accuracy, lower subjective listening effort, and lower oxygenation across the entire prefrontal cortex compared to harder listening conditions. Listening accuracy and subjective listening effort were also significant predictors of oxygenation.</p>","PeriodicalId":48678,"journal":{"name":"Trends in Hearing","volume":"28 ","pages":"23312165241273346"},"PeriodicalIF":2.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363059/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Benefit of Hearing Aids as Measured by Listening Accuracy, Subjective Listening Effort, and Functional Near Infrared Spectroscopy.\",\"authors\":\"Jonathan M Vaisberg, Sean Gilmore, Jinyu Qian, Frank A Russo\",\"doi\":\"10.1177/23312165241273346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There is broad consensus that listening effort is an important outcome for measuring hearing performance. However, there remains debate on the best ways to measure listening effort. This study sought to measure neural correlates of listening effort using functional near-infrared spectroscopy (fNIRS) in experienced adult hearing aid users. The study evaluated impacts of amplification and signal-to-noise ratio (SNR) on cerebral blood oxygenation, with the expectation that easier listening conditions would be associated with less oxygenation in the prefrontal cortex. Thirty experienced adult hearing aid users repeated sentence-final words from low-context Revised Speech Perception in Noise Test sentences. Participants repeated words at a hard SNR (individual SNR-50) or easy SNR (individual SNR-50 + 10 dB), while wearing hearing aids fit to prescriptive targets or without wearing hearing aids. In addition to assessing listening accuracy and subjective listening effort, prefrontal blood oxygenation was measured using fNIRS. As expected, easier listening conditions (i.e., easy SNR, with hearing aids) led to better listening accuracy, lower subjective listening effort, and lower oxygenation across the entire prefrontal cortex compared to harder listening conditions. Listening accuracy and subjective listening effort were also significant predictors of oxygenation.</p>\",\"PeriodicalId\":48678,\"journal\":{\"name\":\"Trends in Hearing\",\"volume\":\"28 \",\"pages\":\"23312165241273346\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363059/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trends in Hearing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/23312165241273346\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23312165241273346","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
The Benefit of Hearing Aids as Measured by Listening Accuracy, Subjective Listening Effort, and Functional Near Infrared Spectroscopy.
There is broad consensus that listening effort is an important outcome for measuring hearing performance. However, there remains debate on the best ways to measure listening effort. This study sought to measure neural correlates of listening effort using functional near-infrared spectroscopy (fNIRS) in experienced adult hearing aid users. The study evaluated impacts of amplification and signal-to-noise ratio (SNR) on cerebral blood oxygenation, with the expectation that easier listening conditions would be associated with less oxygenation in the prefrontal cortex. Thirty experienced adult hearing aid users repeated sentence-final words from low-context Revised Speech Perception in Noise Test sentences. Participants repeated words at a hard SNR (individual SNR-50) or easy SNR (individual SNR-50 + 10 dB), while wearing hearing aids fit to prescriptive targets or without wearing hearing aids. In addition to assessing listening accuracy and subjective listening effort, prefrontal blood oxygenation was measured using fNIRS. As expected, easier listening conditions (i.e., easy SNR, with hearing aids) led to better listening accuracy, lower subjective listening effort, and lower oxygenation across the entire prefrontal cortex compared to harder listening conditions. Listening accuracy and subjective listening effort were also significant predictors of oxygenation.
Trends in HearingAUDIOLOGY & SPEECH-LANGUAGE PATHOLOGYOTORH-OTORHINOLARYNGOLOGY
CiteScore
4.50
自引率
11.10%
发文量
44
审稿时长
12 weeks
期刊介绍:
Trends in Hearing is an open access journal completely dedicated to publishing original research and reviews focusing on human hearing, hearing loss, hearing aids, auditory implants, and aural rehabilitation. Under its former name, Trends in Amplification, the journal established itself as a forum for concise explorations of all areas of translational hearing research by leaders in the field. Trends in Hearing has now expanded its focus to include original research articles, with the goal of becoming the premier venue for research related to human hearing and hearing loss.