MiSight 1 天软性隐形眼镜在韩国近视儿童中的临床疗效。

IF 2 4区 医学 Q2 OPHTHALMOLOGY Eye & Contact Lens-Science and Clinical Practice Pub Date : 2024-10-01 Epub Date: 2024-08-27 DOI:10.1097/ICL.0000000000001117
Hui Kyung Kim, Myung Ho Jo, Yeon Ji Jo, Young Kee Park, Jong Soo Lee
{"title":"MiSight 1 天软性隐形眼镜在韩国近视儿童中的临床疗效。","authors":"Hui Kyung Kim, Myung Ho Jo, Yeon Ji Jo, Young Kee Park, Jong Soo Lee","doi":"10.1097/ICL.0000000000001117","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to investigate the clinical efficacy of MiSight 1 day soft contact lenses (MiSight CL) in Korean children with mild-to-moderate myopia. In addition, the study compared the effects of MiSight CL in children who had or had not previously used orthokeratology contact lenses (Ortho-K).</p><p><strong>Methods: </strong>A total of 66 children aged 5 to 16 years, who were prescribed MiSight CL, were included in the study. Based on a myopia degree of -4 diopters (D), children were divided into mild and severe myopia groups to compare the effectiveness of myopia suppression. In addition, 55 eyes previously using Ortho-K were compared with 76 eyes using MiSight CL for the first time.</p><p><strong>Results: </strong>The average follow-up period was 6.58±3.74 months. The average refractive value before using MiSight CL was 3.64±1.56 D, and there was no significant change in the final visit. Comparing myopia suppression between different degrees of myopia and previous use of Ortho-K lenses, there was no significant change in refractive error before and after using MiSight CL (unpaired t test, P >0.05). The main reason for Ortho-K failure was low visual acuity after correction. Regardless of Ortho-K history, children showed good visual acuity after wearing MiSight CL, and no other side effects were observed.</p><p><strong>Conclusions: </strong>MiSight CL effectively inhibited the progression of myopia in Korean children with mild-to-moderate myopia. MiSight CL offer the advantage of easy application, making them a viable alternative when Ortho-K are not suitable.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":"439-444"},"PeriodicalIF":2.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Efficacy of MiSight 1 day Soft Contact Lenses in Korean Myopic Children.\",\"authors\":\"Hui Kyung Kim, Myung Ho Jo, Yeon Ji Jo, Young Kee Park, Jong Soo Lee\",\"doi\":\"10.1097/ICL.0000000000001117\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aimed to investigate the clinical efficacy of MiSight 1 day soft contact lenses (MiSight CL) in Korean children with mild-to-moderate myopia. In addition, the study compared the effects of MiSight CL in children who had or had not previously used orthokeratology contact lenses (Ortho-K).</p><p><strong>Methods: </strong>A total of 66 children aged 5 to 16 years, who were prescribed MiSight CL, were included in the study. Based on a myopia degree of -4 diopters (D), children were divided into mild and severe myopia groups to compare the effectiveness of myopia suppression. In addition, 55 eyes previously using Ortho-K were compared with 76 eyes using MiSight CL for the first time.</p><p><strong>Results: </strong>The average follow-up period was 6.58±3.74 months. The average refractive value before using MiSight CL was 3.64±1.56 D, and there was no significant change in the final visit. Comparing myopia suppression between different degrees of myopia and previous use of Ortho-K lenses, there was no significant change in refractive error before and after using MiSight CL (unpaired t test, P >0.05). The main reason for Ortho-K failure was low visual acuity after correction. Regardless of Ortho-K history, children showed good visual acuity after wearing MiSight CL, and no other side effects were observed.</p><p><strong>Conclusions: </strong>MiSight CL effectively inhibited the progression of myopia in Korean children with mild-to-moderate myopia. MiSight CL offer the advantage of easy application, making them a viable alternative when Ortho-K are not suitable.</p>\",\"PeriodicalId\":50457,\"journal\":{\"name\":\"Eye & Contact Lens-Science and Clinical Practice\",\"volume\":\" \",\"pages\":\"439-444\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens-Science and Clinical Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000001117\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001117","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在调查 MiSight 1 天软性隐形眼镜(MiSight CL)对韩国轻度至中度近视儿童的临床疗效。此外,该研究还比较了MiSight CL对以前使用过或未使用过矫形角膜接触镜(Ortho-K)的儿童的效果:研究共纳入了 66 名 5-16 岁的儿童,他们都配戴了 MiSight CL。根据近视度数-4d,儿童被分为轻度近视组和重度近视组,以比较抑制近视的效果。此外,55 只曾使用过 Ortho-K 的眼睛与 76 只首次使用 MiSight CL 的眼睛进行了比较:结果:平均随访时间为(6.58±3.74)个月。结果:平均随访时间为(6.58±3.74)个月,使用 MiSight CL 前的平均屈光度值为(3.64±1.56)D,最后一次随访时屈光度值无明显变化。比较不同近视度数的近视抑制情况和以前使用ok镜的情况,使用MiSight CL前后屈光度无明显变化(非配对t检验,P>0.05)。瘢痕矫正失败的主要原因是矫正后视力低下。无论是否有过ok镜矫正史,儿童在佩戴MiSight CL后都显示出良好的视力,而且没有观察到其他副作用:结论:MiSight CL能有效抑制韩国轻度至中度近视儿童的近视发展。MiSight CL具有应用简便的优点,在不适合佩戴ok镜的情况下是一种可行的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical Efficacy of MiSight 1 day Soft Contact Lenses in Korean Myopic Children.

Objectives: This study aimed to investigate the clinical efficacy of MiSight 1 day soft contact lenses (MiSight CL) in Korean children with mild-to-moderate myopia. In addition, the study compared the effects of MiSight CL in children who had or had not previously used orthokeratology contact lenses (Ortho-K).

Methods: A total of 66 children aged 5 to 16 years, who were prescribed MiSight CL, were included in the study. Based on a myopia degree of -4 diopters (D), children were divided into mild and severe myopia groups to compare the effectiveness of myopia suppression. In addition, 55 eyes previously using Ortho-K were compared with 76 eyes using MiSight CL for the first time.

Results: The average follow-up period was 6.58±3.74 months. The average refractive value before using MiSight CL was 3.64±1.56 D, and there was no significant change in the final visit. Comparing myopia suppression between different degrees of myopia and previous use of Ortho-K lenses, there was no significant change in refractive error before and after using MiSight CL (unpaired t test, P >0.05). The main reason for Ortho-K failure was low visual acuity after correction. Regardless of Ortho-K history, children showed good visual acuity after wearing MiSight CL, and no other side effects were observed.

Conclusions: MiSight CL effectively inhibited the progression of myopia in Korean children with mild-to-moderate myopia. MiSight CL offer the advantage of easy application, making them a viable alternative when Ortho-K are not suitable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
4.30%
发文量
150
审稿时长
6-12 weeks
期刊介绍: Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.
期刊最新文献
Artificial Doctors: Performance of Chatbots as a Tool for Patient Education on Keratoconus. Comparative Analysis of Cosmetic and Functional Outcomes in Corneal Tattooing (Keratopigmentation) versus Ocular Prosthesis. Drug Delivery in PROSE Device as Alternative to Frequent Drop Administration in Severe Ocular Surface Disease. Factors Contributing to Follow-up Nonadherence After Infectious Keratitis Diagnosis. Quality of Life Survey Using NEI VFQ-25 in Japanese Patients With Fuchs Endothelial Corneal Dystrophy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1