利用 Geant4 工具包对基于 D-D 中子发生器的热中子装置进行优化和屏蔽设计

IF 1.6 3区 工程技术 Q3 CHEMISTRY, INORGANIC & NUCLEAR Applied Radiation and Isotopes Pub Date : 2024-08-26 DOI:10.1016/j.apradiso.2024.111483
Guang Yang , Rui Shi , Jianbo Yang , Xianguo Tuo
{"title":"利用 Geant4 工具包对基于 D-D 中子发生器的热中子装置进行优化和屏蔽设计","authors":"Guang Yang ,&nbsp;Rui Shi ,&nbsp;Jianbo Yang ,&nbsp;Xianguo Tuo","doi":"10.1016/j.apradiso.2024.111483","DOIUrl":null,"url":null,"abstract":"<div><p>Neutron activation analysis is a highly sensitive non-destructive testing technique with important applications in industry, geoscience, medical therapy, etc. This work designed and optimized a thermal neutron device that utilized a portable D-D neutron generator, and the Monte Carlo method with the Geant4 toolkit was applied to simulation. The objective of the optimized design is to maximize the thermal neutron flux at the output surface and increase the utilization efficiency of the neutron generator. A parameter K was defined as a measure of the device's slowing capacity for neutrons and was used to determine the optimized device geometry. The simulation considered the contribution of different types and sizes of moderators and reflectors to the thermal neutron intensity to obtain the optimal size. The shielding protection of the device was then designed. The effectiveness of shielding with different thicknesses was evaluated using three dose reference points. The results indicated that the optimized device can achieve a maximum thermal neutron flux of 1.97 × 10<sup>5</sup> n∙cm<sup>−2</sup>∙s<sup>−1</sup> at the output surface by using high-density polyethylene (HDPE) as the moderator and nickel as the reflector. It was determined that using 45 cm of HDPE and 9 cm of lead protection in sequence along the neutron head axis would reduce the dose rate at the reference point, located 5 cm from the surface of the device, below the safety limit of 2.5 μSv/h.</p></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":"212 ","pages":"Article 111483"},"PeriodicalIF":1.6000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization and shielding design of a thermal neutron device based on D-D neutron generator with Geant4 toolkit\",\"authors\":\"Guang Yang ,&nbsp;Rui Shi ,&nbsp;Jianbo Yang ,&nbsp;Xianguo Tuo\",\"doi\":\"10.1016/j.apradiso.2024.111483\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Neutron activation analysis is a highly sensitive non-destructive testing technique with important applications in industry, geoscience, medical therapy, etc. This work designed and optimized a thermal neutron device that utilized a portable D-D neutron generator, and the Monte Carlo method with the Geant4 toolkit was applied to simulation. The objective of the optimized design is to maximize the thermal neutron flux at the output surface and increase the utilization efficiency of the neutron generator. A parameter K was defined as a measure of the device's slowing capacity for neutrons and was used to determine the optimized device geometry. The simulation considered the contribution of different types and sizes of moderators and reflectors to the thermal neutron intensity to obtain the optimal size. The shielding protection of the device was then designed. The effectiveness of shielding with different thicknesses was evaluated using three dose reference points. The results indicated that the optimized device can achieve a maximum thermal neutron flux of 1.97 × 10<sup>5</sup> n∙cm<sup>−2</sup>∙s<sup>−1</sup> at the output surface by using high-density polyethylene (HDPE) as the moderator and nickel as the reflector. It was determined that using 45 cm of HDPE and 9 cm of lead protection in sequence along the neutron head axis would reduce the dose rate at the reference point, located 5 cm from the surface of the device, below the safety limit of 2.5 μSv/h.</p></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":\"212 \",\"pages\":\"Article 111483\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-08-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969804324003117\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969804324003117","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

中子活化分析是一种高灵敏度的无损检测技术,在工业、地球科学、医疗等领域有着重要应用。这项研究设计并优化了一种利用便携式 D-D 中子发生器的热中子装置,并利用 Geant4 工具包的蒙特卡罗方法进行了模拟。优化设计的目标是使输出表面的热中子通量最大化,并提高中子发生器的利用效率。参数 K 被定义为设备中子慢化能力的量度,用于确定优化的设备几何形状。模拟考虑了不同类型和尺寸的慢化剂和反射器对热中子强度的贡献,以获得最佳尺寸。然后设计了装置的屏蔽保护。利用三个剂量参考点对不同厚度的屏蔽效果进行了评估。结果表明,通过使用高密度聚乙烯(HDPE)作为慢化剂和镍作为反射器,优化后的装置可在输出表面获得 1.97 × 105 n∙cm-2∙s-1 的最大热中子通量。据测定,沿中子头轴线依次使用 45 厘米的高密度聚乙烯和 9 厘米的铅保护层,可将距离装置表面 5 厘米的参考点处的剂量率降至 2.5 μSv/h 的安全限值以下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization and shielding design of a thermal neutron device based on D-D neutron generator with Geant4 toolkit

Neutron activation analysis is a highly sensitive non-destructive testing technique with important applications in industry, geoscience, medical therapy, etc. This work designed and optimized a thermal neutron device that utilized a portable D-D neutron generator, and the Monte Carlo method with the Geant4 toolkit was applied to simulation. The objective of the optimized design is to maximize the thermal neutron flux at the output surface and increase the utilization efficiency of the neutron generator. A parameter K was defined as a measure of the device's slowing capacity for neutrons and was used to determine the optimized device geometry. The simulation considered the contribution of different types and sizes of moderators and reflectors to the thermal neutron intensity to obtain the optimal size. The shielding protection of the device was then designed. The effectiveness of shielding with different thicknesses was evaluated using three dose reference points. The results indicated that the optimized device can achieve a maximum thermal neutron flux of 1.97 × 105 n∙cm−2∙s−1 at the output surface by using high-density polyethylene (HDPE) as the moderator and nickel as the reflector. It was determined that using 45 cm of HDPE and 9 cm of lead protection in sequence along the neutron head axis would reduce the dose rate at the reference point, located 5 cm from the surface of the device, below the safety limit of 2.5 μSv/h.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Radiation and Isotopes
Applied Radiation and Isotopes 工程技术-核科学技术
CiteScore
3.00
自引率
12.50%
发文量
406
审稿时长
13.5 months
期刊介绍: Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.
期刊最新文献
Investigating cross-section effects on HPGe detector response through computational and empirical approaches Impact of low dose of gamma irradiation on thin films of Bismuth Tri-iodide A matrix effect correction method for fissile nuclear material mass measurement by delayed neutrons Mapping sensitivity of CVD diamond detector using synchrotron micro-beam Validation of a general-use high flux isotope reactor–specific metaheuristic optimization framework for isotope production target design
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1