{"title":"利用设计信息和微震颤测量,考虑非结构元素的木结构房屋初始刚度估算方法","authors":"Shinta Yoshitomi, Takahiro Sada, Takuro Habara","doi":"10.1002/2475-8876.12461","DOIUrl":null,"url":null,"abstract":"<p>In this paper, a previously proposed method for story stiffness estimation of steel residential house is extended to estimate story stiffness of wooden residential houses considering non-structural walls based on the available design information, that is, story weights, wall type, wall length, and wall opening type. Microtremor measurement data of several newly constructed buildings are used to determine unknown model parameters of stiffness estimation function, which minimize the estimation error of eigen frequency. The proposed method can simultaneously estimate the standard stiffness of wall element common to the same specification and the effects of wall opening and wall shape. The validity of the proposed method is examined by using measured actual microtremor records and drawing information of wall types and wall lengths of 19 wooden residential houses.</p>","PeriodicalId":42793,"journal":{"name":"Japan Architectural Review","volume":"7 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.12461","citationCount":"0","resultStr":"{\"title\":\"Initial stiffness estimation method for wooden house considering non-structural elements using design information and microtremor measurement\",\"authors\":\"Shinta Yoshitomi, Takahiro Sada, Takuro Habara\",\"doi\":\"10.1002/2475-8876.12461\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In this paper, a previously proposed method for story stiffness estimation of steel residential house is extended to estimate story stiffness of wooden residential houses considering non-structural walls based on the available design information, that is, story weights, wall type, wall length, and wall opening type. Microtremor measurement data of several newly constructed buildings are used to determine unknown model parameters of stiffness estimation function, which minimize the estimation error of eigen frequency. The proposed method can simultaneously estimate the standard stiffness of wall element common to the same specification and the effects of wall opening and wall shape. The validity of the proposed method is examined by using measured actual microtremor records and drawing information of wall types and wall lengths of 19 wooden residential houses.</p>\",\"PeriodicalId\":42793,\"journal\":{\"name\":\"Japan Architectural Review\",\"volume\":\"7 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.12461\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japan Architectural Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.12461\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japan Architectural Review","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.12461","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
Initial stiffness estimation method for wooden house considering non-structural elements using design information and microtremor measurement
In this paper, a previously proposed method for story stiffness estimation of steel residential house is extended to estimate story stiffness of wooden residential houses considering non-structural walls based on the available design information, that is, story weights, wall type, wall length, and wall opening type. Microtremor measurement data of several newly constructed buildings are used to determine unknown model parameters of stiffness estimation function, which minimize the estimation error of eigen frequency. The proposed method can simultaneously estimate the standard stiffness of wall element common to the same specification and the effects of wall opening and wall shape. The validity of the proposed method is examined by using measured actual microtremor records and drawing information of wall types and wall lengths of 19 wooden residential houses.