中国鼻腔功能测试-22:波兰语患者的翻译、跨文化适应和验证。

IF 1.9 3区 医学 Q2 OTORHINOLARYNGOLOGY European Archives of Oto-Rhino-Laryngology Pub Date : 2024-12-01 Epub Date: 2024-08-28 DOI:10.1007/s00405-024-08919-z
Joanna Morawska, Joanna Jeruzal-Świątecka, Piotr Politański, Wioletta Pietruszewska
{"title":"中国鼻腔功能测试-22:波兰语患者的翻译、跨文化适应和验证。","authors":"Joanna Morawska, Joanna Jeruzal-Świątecka, Piotr Politański, Wioletta Pietruszewska","doi":"10.1007/s00405-024-08919-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>There are many specific instruments for assessing the quality of life (QoL) in patients with chronic rhinosinusitis. Of all these tests, the Sino-Nasal Outcome Test-22 (SNOT-22) is the most widely used internationally. The purpose of the study was linguistic adaptation and validation of the SNOT-22 scale in the Polish language.</p><p><strong>Methods: </strong>The SNOT-22 was adapted into Polish and was administered to 148 subjects (108 patients with chronic rhinosinusitis with nasal polyps (CRSwNP) and 40 asymptomatic controls. Seventy-one patients completed the SNOT-22 a second time to evaluate test-retest reliability. The Polish SNOT-22 was assessed for internal consistency, test-retest reliability, discriminant validity, criterion validity, and sensitivity and specificity.</p><p><strong>Results: </strong>The Polish SNOT-22 exhibited satisfactory psychometric properties. A high Cronbach's alpha coefficient (α = 0.89) was obtained. Significantly higher scores (p < 0.01) were revealed in the Study Group with a median score of 32 (range 15-53) points in comparison with controls: 5 (range 0-20). A moderate correlation was found between SNOT-22 and the Lund-Kennedy test score (r = 0.334; p < 0.001) and a strong correlation between SNOT-22 and the Lund-Macay test score (r = 0.469; p < 0.001). The best cut-off point was set at a 16 score with a sensitivity of 0.981 and a specificity of 0.995. The determined Area Under Curve (AUC = 0.997; p < 0.001) confirms the diagnostic accuracy of the Polish SNOT-22.</p><p><strong>Conclusions: </strong>The Polish version of the SNOT-22 is a valid and reliable tool for measuring health-related quality of life in patients with CRSwNP in the Polish-speaking population.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":" ","pages":"6431-6443"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11564299/pdf/","citationCount":"0","resultStr":"{\"title\":\"Sino-Nasal Outcome Test-22: translation, cross-cultural adaptation, and validation in Polish-speaking patients.\",\"authors\":\"Joanna Morawska, Joanna Jeruzal-Świątecka, Piotr Politański, Wioletta Pietruszewska\",\"doi\":\"10.1007/s00405-024-08919-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>There are many specific instruments for assessing the quality of life (QoL) in patients with chronic rhinosinusitis. Of all these tests, the Sino-Nasal Outcome Test-22 (SNOT-22) is the most widely used internationally. The purpose of the study was linguistic adaptation and validation of the SNOT-22 scale in the Polish language.</p><p><strong>Methods: </strong>The SNOT-22 was adapted into Polish and was administered to 148 subjects (108 patients with chronic rhinosinusitis with nasal polyps (CRSwNP) and 40 asymptomatic controls. Seventy-one patients completed the SNOT-22 a second time to evaluate test-retest reliability. The Polish SNOT-22 was assessed for internal consistency, test-retest reliability, discriminant validity, criterion validity, and sensitivity and specificity.</p><p><strong>Results: </strong>The Polish SNOT-22 exhibited satisfactory psychometric properties. A high Cronbach's alpha coefficient (α = 0.89) was obtained. Significantly higher scores (p < 0.01) were revealed in the Study Group with a median score of 32 (range 15-53) points in comparison with controls: 5 (range 0-20). A moderate correlation was found between SNOT-22 and the Lund-Kennedy test score (r = 0.334; p < 0.001) and a strong correlation between SNOT-22 and the Lund-Macay test score (r = 0.469; p < 0.001). The best cut-off point was set at a 16 score with a sensitivity of 0.981 and a specificity of 0.995. The determined Area Under Curve (AUC = 0.997; p < 0.001) confirms the diagnostic accuracy of the Polish SNOT-22.</p><p><strong>Conclusions: </strong>The Polish version of the SNOT-22 is a valid and reliable tool for measuring health-related quality of life in patients with CRSwNP in the Polish-speaking population.</p>\",\"PeriodicalId\":11952,\"journal\":{\"name\":\"European Archives of Oto-Rhino-Laryngology\",\"volume\":\" \",\"pages\":\"6431-6443\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11564299/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Archives of Oto-Rhino-Laryngology\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1007/s00405-024-08919-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00405-024-08919-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估慢性鼻炎患者生活质量(QoL)的具体工具有很多。在所有这些测试中,Sino-Nasal Outcome Test-22 (SNOT-22) 是国际上使用最广泛的一种。本研究的目的是在波兰语中对 SNOT-22 量表进行语言改编和验证:将 SNOT-22 改编成波兰语后,对 148 名受试者(108 名慢性鼻炎伴鼻息肉(CRSwNP)患者和 40 名无症状对照者)进行了测试。71 名患者第二次完成了 SNOT-22,以评估测试-再测可靠性。对波兰 SNOT-22 进行了内部一致性、重测可靠性、判别效度、标准效度以及敏感性和特异性评估:结果:波兰语 SNOT-22 具有令人满意的心理测量特性。Cronbach's α系数较高(α = 0.89)。波兰语版 SNOT-22 的得分(p 结论:波兰语版 SNOT-22 的得分显著高于波兰语版:波兰语版 SNOT-22 是测量波兰语人群中 CRSwNP 患者健康相关生活质量的有效而可靠的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Sino-Nasal Outcome Test-22: translation, cross-cultural adaptation, and validation in Polish-speaking patients.

Purpose: There are many specific instruments for assessing the quality of life (QoL) in patients with chronic rhinosinusitis. Of all these tests, the Sino-Nasal Outcome Test-22 (SNOT-22) is the most widely used internationally. The purpose of the study was linguistic adaptation and validation of the SNOT-22 scale in the Polish language.

Methods: The SNOT-22 was adapted into Polish and was administered to 148 subjects (108 patients with chronic rhinosinusitis with nasal polyps (CRSwNP) and 40 asymptomatic controls. Seventy-one patients completed the SNOT-22 a second time to evaluate test-retest reliability. The Polish SNOT-22 was assessed for internal consistency, test-retest reliability, discriminant validity, criterion validity, and sensitivity and specificity.

Results: The Polish SNOT-22 exhibited satisfactory psychometric properties. A high Cronbach's alpha coefficient (α = 0.89) was obtained. Significantly higher scores (p < 0.01) were revealed in the Study Group with a median score of 32 (range 15-53) points in comparison with controls: 5 (range 0-20). A moderate correlation was found between SNOT-22 and the Lund-Kennedy test score (r = 0.334; p < 0.001) and a strong correlation between SNOT-22 and the Lund-Macay test score (r = 0.469; p < 0.001). The best cut-off point was set at a 16 score with a sensitivity of 0.981 and a specificity of 0.995. The determined Area Under Curve (AUC = 0.997; p < 0.001) confirms the diagnostic accuracy of the Polish SNOT-22.

Conclusions: The Polish version of the SNOT-22 is a valid and reliable tool for measuring health-related quality of life in patients with CRSwNP in the Polish-speaking population.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
7.70%
发文量
537
审稿时长
2-4 weeks
期刊介绍: Official Journal of European Union of Medical Specialists – ORL Section and Board Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery "European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level. European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.
期刊最新文献
Correction: Endoscopic ear surgery in the treatment of chronic otitis media with atelectasis. Correction: A novel olfactory sorting task. Cochlear implantation in patients with inner ear schwannomas: a systematic review and meta-analysis of audiological outcomes. Efficacy and safety of middle turbinate surgery: a systematic review. Idiopathic sudden sensorineural hearing loss after COVID-19 vaccination: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1