澳大利亚和新西兰麻醉实践中的食管插管:对 109 起事件的网络 AIRS 分析。

IF 1.1 4区 医学 Q3 ANESTHESIOLOGY Anaesthesia and Intensive Care Pub Date : 2024-09-01 Epub Date: 2024-08-31 DOI:10.1177/0310057X241244809
Yasmin Endlich, Thomas P Fox, Martin D Culwick, Christopher J Acott
{"title":"澳大利亚和新西兰麻醉实践中的食管插管:对 109 起事件的网络 AIRS 分析。","authors":"Yasmin Endlich, Thomas P Fox, Martin D Culwick, Christopher J Acott","doi":"10.1177/0310057X241244809","DOIUrl":null,"url":null,"abstract":"<p><p>Oesophageal intubations are more common than may be realised and can potentially cause significant patient harm even if promptly identified and corrected. Reports of morbidity due to unrecognised oesophageal intubation continue to present in coroner and media reports. Therefore, it would be helpful to identify mechanisms to prevent these events and implement strategies to avoid and identify incorrect endotracheal tube placement. This analysis of oesophageal intubations reported to webAIRS aims to provide an in-depth analysis of all events in which oesophageal intubation occurred. WebAIRS is a web-based, bi-national incident reporting system collecting voluntarily reported anaesthetic events across Australia and New Zealand, with more than 10,500 incidents registered. A structured search through the webAIRS database identified 109 reports of oesophageal intubation reported between July 2009 and September 2022. A common cause of oesophageal intubation was the misidentification of the larynx due to a poor laryngeal view. Desaturation directly attributed to the misplaced endotracheal tube occurred in 43% of all reports. The authors precisely defined early recognised oesophageal intubation and delayed or unrecognised oesophageal intubation. Most reports (74%) described early recognition of the misplaced intubation, of which 27% led to directly contributed to hypoxia. Cardiovascular collapse as a direct consequence of the late recognition of oesophageal intubation was described in five (18%) of these events. There was inconsistency in end-tidal carbon dioxide monitoring and interpretation of the resulting waveform. Findings show that oesophageal intubation continues to be an issue in anaesthesia. Incidents described confusion in diagnosis, human factors issues and cognitive bias. Clear diagnostic guidance and treatment strategies are required to be developed, tested and implemented.</p>","PeriodicalId":7746,"journal":{"name":"Anaesthesia and Intensive Care","volume":" ","pages":"302-313"},"PeriodicalIF":1.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Oesophageal intubations in anaesthetic practice across Australia and New Zealand: A webAIRS analysis of 109 incidents.\",\"authors\":\"Yasmin Endlich, Thomas P Fox, Martin D Culwick, Christopher J Acott\",\"doi\":\"10.1177/0310057X241244809\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Oesophageal intubations are more common than may be realised and can potentially cause significant patient harm even if promptly identified and corrected. Reports of morbidity due to unrecognised oesophageal intubation continue to present in coroner and media reports. Therefore, it would be helpful to identify mechanisms to prevent these events and implement strategies to avoid and identify incorrect endotracheal tube placement. This analysis of oesophageal intubations reported to webAIRS aims to provide an in-depth analysis of all events in which oesophageal intubation occurred. WebAIRS is a web-based, bi-national incident reporting system collecting voluntarily reported anaesthetic events across Australia and New Zealand, with more than 10,500 incidents registered. A structured search through the webAIRS database identified 109 reports of oesophageal intubation reported between July 2009 and September 2022. A common cause of oesophageal intubation was the misidentification of the larynx due to a poor laryngeal view. Desaturation directly attributed to the misplaced endotracheal tube occurred in 43% of all reports. The authors precisely defined early recognised oesophageal intubation and delayed or unrecognised oesophageal intubation. Most reports (74%) described early recognition of the misplaced intubation, of which 27% led to directly contributed to hypoxia. Cardiovascular collapse as a direct consequence of the late recognition of oesophageal intubation was described in five (18%) of these events. There was inconsistency in end-tidal carbon dioxide monitoring and interpretation of the resulting waveform. Findings show that oesophageal intubation continues to be an issue in anaesthesia. Incidents described confusion in diagnosis, human factors issues and cognitive bias. Clear diagnostic guidance and treatment strategies are required to be developed, tested and implemented.</p>\",\"PeriodicalId\":7746,\"journal\":{\"name\":\"Anaesthesia and Intensive Care\",\"volume\":\" \",\"pages\":\"302-313\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesia and Intensive Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/0310057X241244809\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia and Intensive Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/0310057X241244809","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

食道插管比人们意识到的更为常见,即使及时发现并纠正,也可能对患者造成重大伤害。在验尸官和媒体报道中,因未识别食道插管而导致的发病率仍时有发生。因此,找出预防这些事件的机制并实施避免和识别错误气管插管的策略将大有裨益。此次对 WebAIRS 报告的食管插管事件进行分析,旨在对发生食管插管的所有事件进行深入分析。WebAIRS 是一个基于网络的两国事故报告系统,收集了澳大利亚和新西兰两国自愿报告的麻醉事故,登记在册的事故超过 10,500 起。通过对 WebAIRS 数据库进行结构化搜索,发现 2009 年 7 月至 2022 年 9 月期间共报告了 109 起食道插管事件。食道插管的常见原因是喉部视野不佳导致喉部识别错误。在所有报告中,43%的患者因气管插管位置错误而直接导致呼吸减弱。作者对早期识别的食管插管和延迟或未识别的食管插管进行了精确定义。大多数报告(74%)描述了早期识别错位插管的情况,其中 27% 直接导致了缺氧。在这些事件中,有五例(18%)描述了食管插管识别过晚直接导致的心血管衰竭。潮气末二氧化碳监测和对所产生波形的解释不一致。研究结果表明,食管插管仍然是麻醉中的一个问题。事件描述了诊断混乱、人为因素问题和认知偏差。需要制定、测试和实施明确的诊断指导和治疗策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Oesophageal intubations in anaesthetic practice across Australia and New Zealand: A webAIRS analysis of 109 incidents.

Oesophageal intubations are more common than may be realised and can potentially cause significant patient harm even if promptly identified and corrected. Reports of morbidity due to unrecognised oesophageal intubation continue to present in coroner and media reports. Therefore, it would be helpful to identify mechanisms to prevent these events and implement strategies to avoid and identify incorrect endotracheal tube placement. This analysis of oesophageal intubations reported to webAIRS aims to provide an in-depth analysis of all events in which oesophageal intubation occurred. WebAIRS is a web-based, bi-national incident reporting system collecting voluntarily reported anaesthetic events across Australia and New Zealand, with more than 10,500 incidents registered. A structured search through the webAIRS database identified 109 reports of oesophageal intubation reported between July 2009 and September 2022. A common cause of oesophageal intubation was the misidentification of the larynx due to a poor laryngeal view. Desaturation directly attributed to the misplaced endotracheal tube occurred in 43% of all reports. The authors precisely defined early recognised oesophageal intubation and delayed or unrecognised oesophageal intubation. Most reports (74%) described early recognition of the misplaced intubation, of which 27% led to directly contributed to hypoxia. Cardiovascular collapse as a direct consequence of the late recognition of oesophageal intubation was described in five (18%) of these events. There was inconsistency in end-tidal carbon dioxide monitoring and interpretation of the resulting waveform. Findings show that oesophageal intubation continues to be an issue in anaesthesia. Incidents described confusion in diagnosis, human factors issues and cognitive bias. Clear diagnostic guidance and treatment strategies are required to be developed, tested and implemented.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
13.30%
发文量
150
审稿时长
3 months
期刊介绍: Anaesthesia and Intensive Care is an international journal publishing timely, peer reviewed articles that have educational value and scientific merit for clinicians and researchers associated with anaesthesia, intensive care medicine, and pain medicine.
期刊最新文献
Experiences and outcomes of patients participating in a perioperative shared decision-making pathway. JG Farrell and The Lung: An early description of intensive care delirium in literature. Promoting behavioural change by educating anaesthetists about the environmental impact of inhalational anaesthetic agents: A systematic review. MET call prevention. A cross-sectional study of the relationship between iron deficiency anaemia and chronic pain.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1