Demosthenes G Katritsis, Konstantinos C Siontis, Sharad Agarwal, Stavros Stavrakis, Eleftherios Giazitzoglou, Hina Amin, Joseph E Marine, Justin T Tretter, Damian Sanchez-Quintana, Robert H Anderson, Hugh Calkins
{"title":"房室结的解剖消融。","authors":"Demosthenes G Katritsis, Konstantinos C Siontis, Sharad Agarwal, Stavros Stavrakis, Eleftherios Giazitzoglou, Hina Amin, Joseph E Marine, Justin T Tretter, Damian Sanchez-Quintana, Robert H Anderson, Hugh Calkins","doi":"10.15420/aer.2024.13","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Atrioventricular (AV) conduction ablation has been achieved by targeting the area of penetration of the conduction axis as defined by recording a His bundle potential. Ablation of the His bundle may reduce the possibility of a robust junctional escape rhythm. It was hypothesised that specific AV nodal ablation is feasible and safe.</p><p><strong>Methods: </strong>The anatomical position of the AV node in relation to the site of penetration of the conduction axis was identified as described in dissections and histological sections of human hearts. Radiofrequency (RF) ablation was accomplished based on the anatomical criteria.</p><p><strong>Results: </strong>Specific anatomical ablation of the AV node was attempted in 72 patients. Successful AV nodal ablation was accomplished in 63 patients (87.5%), following 60 minutes (IQR 50-70 minutes) of procedure time, 3.4 minutes (IQR 2.4-5.5 minutes) of fluoroscopy time, and delivery of 4 (IQR 3-6) RF lesions. An escape rhythm was present in 45 patients (71%), and the QRS complex was similar to that before ablation in all 45 patients. Atropine was administered in six patients after the 10-min waiting period and did not result in restoration of conduction. In nine patients, AV conduction could not be interrupted, and AV block was achieved with ablation of the His after delivery of 12 (IQR 8-15) RF lesions. No cases of sudden death were encountered, and all patients had persistent AV block during a median 10.5 months (IQR 5-14 months) of follow-up.</p><p><strong>Conclusion: </strong>Anatomical ablation of the AV node is feasible and safe, and results in an escape rhythm similar to that before ablation.</p>","PeriodicalId":8412,"journal":{"name":"Arrhythmia & Electrophysiology Review","volume":"13 ","pages":"e12"},"PeriodicalIF":2.6000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363056/pdf/","citationCount":"0","resultStr":"{\"title\":\"Anatomical Ablation of the Atrioventricular Node.\",\"authors\":\"Demosthenes G Katritsis, Konstantinos C Siontis, Sharad Agarwal, Stavros Stavrakis, Eleftherios Giazitzoglou, Hina Amin, Joseph E Marine, Justin T Tretter, Damian Sanchez-Quintana, Robert H Anderson, Hugh Calkins\",\"doi\":\"10.15420/aer.2024.13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Atrioventricular (AV) conduction ablation has been achieved by targeting the area of penetration of the conduction axis as defined by recording a His bundle potential. Ablation of the His bundle may reduce the possibility of a robust junctional escape rhythm. It was hypothesised that specific AV nodal ablation is feasible and safe.</p><p><strong>Methods: </strong>The anatomical position of the AV node in relation to the site of penetration of the conduction axis was identified as described in dissections and histological sections of human hearts. Radiofrequency (RF) ablation was accomplished based on the anatomical criteria.</p><p><strong>Results: </strong>Specific anatomical ablation of the AV node was attempted in 72 patients. Successful AV nodal ablation was accomplished in 63 patients (87.5%), following 60 minutes (IQR 50-70 minutes) of procedure time, 3.4 minutes (IQR 2.4-5.5 minutes) of fluoroscopy time, and delivery of 4 (IQR 3-6) RF lesions. An escape rhythm was present in 45 patients (71%), and the QRS complex was similar to that before ablation in all 45 patients. Atropine was administered in six patients after the 10-min waiting period and did not result in restoration of conduction. In nine patients, AV conduction could not be interrupted, and AV block was achieved with ablation of the His after delivery of 12 (IQR 8-15) RF lesions. No cases of sudden death were encountered, and all patients had persistent AV block during a median 10.5 months (IQR 5-14 months) of follow-up.</p><p><strong>Conclusion: </strong>Anatomical ablation of the AV node is feasible and safe, and results in an escape rhythm similar to that before ablation.</p>\",\"PeriodicalId\":8412,\"journal\":{\"name\":\"Arrhythmia & Electrophysiology Review\",\"volume\":\"13 \",\"pages\":\"e12\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-08-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363056/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arrhythmia & Electrophysiology Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/aer.2024.13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arrhythmia & Electrophysiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/aer.2024.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
背景:房室(AV)传导消融是通过记录 His 束电位来确定传导轴的穿透区域。消融 His 束可能会降低出现强有力的交界性逸搏节律的可能性。假设特定房室结消融是可行且安全的:方法:根据人体心脏解剖和组织切片的描述,确定房室结与传导轴穿透部位的解剖位置。根据解剖学标准完成射频消融:结果:72 名患者尝试了房室结的特定解剖消融术。63名患者(87.5%)成功完成了房室结消融,手术时间为60分钟(IQR 50-70分钟),透视时间为3.4分钟(IQR 2.4-5.5分钟),射频病灶为4个(IQR 3-6个)。45 名患者(71%)出现了逃逸心律,所有 45 名患者的 QRS 波群与消融前相似。六名患者在 10 分钟等待期后服用了阿托品,但并未恢复传导。有 9 名患者的房室传导无法中断,在进行了 12 次(IQR 8-15 次)射频病变后,通过消融 His 实现了房室传导阻滞。在中位 10.5 个月(IQR 5-14 个月)的随访期间,所有患者均出现持续性房室传导阻滞,无猝死病例:结论:对房室结进行解剖性消融是可行且安全的,其结果与消融前的逃逸节律相似。
Background: Atrioventricular (AV) conduction ablation has been achieved by targeting the area of penetration of the conduction axis as defined by recording a His bundle potential. Ablation of the His bundle may reduce the possibility of a robust junctional escape rhythm. It was hypothesised that specific AV nodal ablation is feasible and safe.
Methods: The anatomical position of the AV node in relation to the site of penetration of the conduction axis was identified as described in dissections and histological sections of human hearts. Radiofrequency (RF) ablation was accomplished based on the anatomical criteria.
Results: Specific anatomical ablation of the AV node was attempted in 72 patients. Successful AV nodal ablation was accomplished in 63 patients (87.5%), following 60 minutes (IQR 50-70 minutes) of procedure time, 3.4 minutes (IQR 2.4-5.5 minutes) of fluoroscopy time, and delivery of 4 (IQR 3-6) RF lesions. An escape rhythm was present in 45 patients (71%), and the QRS complex was similar to that before ablation in all 45 patients. Atropine was administered in six patients after the 10-min waiting period and did not result in restoration of conduction. In nine patients, AV conduction could not be interrupted, and AV block was achieved with ablation of the His after delivery of 12 (IQR 8-15) RF lesions. No cases of sudden death were encountered, and all patients had persistent AV block during a median 10.5 months (IQR 5-14 months) of follow-up.
Conclusion: Anatomical ablation of the AV node is feasible and safe, and results in an escape rhythm similar to that before ablation.