双层扩散反射测量中交叉点对吸收变化的依赖性。

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of Biomedical Optics Pub Date : 2024-08-01 Epub Date: 2024-08-28 DOI:10.1117/1.JBO.29.8.087001
Channa Shapira, Yuval Yedvav, Hamootal Duadi, Haim Taitelbaum, Dror Fixler
{"title":"双层扩散反射测量中交叉点对吸收变化的依赖性。","authors":"Channa Shapira, Yuval Yedvav, Hamootal Duadi, Haim Taitelbaum, Dror Fixler","doi":"10.1117/1.JBO.29.8.087001","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>A better understanding of diffusion reflection (DR) behavior may allow it to be used for more noninvasive applications, including the development of <i>in vivo</i> non-damaging techniques, especially for medical topical diagnosis and treatments.</p><p><strong>Aim: </strong>For a bilayer opaque substance where the attenuation of the upper layer is larger than the attenuation of the lower layer, the DR crossover point ( <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> ) is location where the photons coming from the bottom layer start affecting the DR. We aim to study the dependency of the <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> on absorption changes in different layers for constant scattering and top layer thickness.</p><p><strong>Approach: </strong>Monolayer and bilayer optical tissue-like phantoms were prepared and measured using a DR system. The results were compared with Monte Carlo simulations.</p><p><strong>Results: </strong>There is an agreement between the experiments and the simulations. <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> correlates with the square root of the absorption coefficient ratio of the lower layer to the top layer.</p><p><strong>Conclusion: </strong>The experimental findings support and validate the theoretical prediction describing the dependency of the <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> on the square root of the ratio of the layers' absorption coefficients. In addition, a secondary breaking point is suggested to be observed experimentally at the entrance to the noise area.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"29 8","pages":"087001"},"PeriodicalIF":3.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11350519/pdf/","citationCount":"0","resultStr":"{\"title\":\"Dependency of crossover point on absorption changes in bilayer diffusion reflection measurements.\",\"authors\":\"Channa Shapira, Yuval Yedvav, Hamootal Duadi, Haim Taitelbaum, Dror Fixler\",\"doi\":\"10.1117/1.JBO.29.8.087001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>A better understanding of diffusion reflection (DR) behavior may allow it to be used for more noninvasive applications, including the development of <i>in vivo</i> non-damaging techniques, especially for medical topical diagnosis and treatments.</p><p><strong>Aim: </strong>For a bilayer opaque substance where the attenuation of the upper layer is larger than the attenuation of the lower layer, the DR crossover point ( <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> ) is location where the photons coming from the bottom layer start affecting the DR. We aim to study the dependency of the <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> on absorption changes in different layers for constant scattering and top layer thickness.</p><p><strong>Approach: </strong>Monolayer and bilayer optical tissue-like phantoms were prepared and measured using a DR system. The results were compared with Monte Carlo simulations.</p><p><strong>Results: </strong>There is an agreement between the experiments and the simulations. <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> correlates with the square root of the absorption coefficient ratio of the lower layer to the top layer.</p><p><strong>Conclusion: </strong>The experimental findings support and validate the theoretical prediction describing the dependency of the <math> <mrow><msub><mi>C</mi> <mi>p</mi></msub> </mrow> </math> on the square root of the ratio of the layers' absorption coefficients. In addition, a secondary breaking point is suggested to be observed experimentally at the entrance to the noise area.</p>\",\"PeriodicalId\":15264,\"journal\":{\"name\":\"Journal of Biomedical Optics\",\"volume\":\"29 8\",\"pages\":\"087001\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11350519/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomedical Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JBO.29.8.087001\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.29.8.087001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

意义:目的:对于上层衰减大于下层衰减的双层不透明物质,DR交叉点(C p)是指来自底层的光子开始影响DR的位置。我们旨在研究在散射和顶层厚度不变的情况下,C p 与不同层吸收变化的关系:方法:使用 DR 系统制备并测量单层和双层类光学组织模型。方法:使用 DR 系统制备并测量单层和双层光学组织模型,并将结果与蒙特卡罗模拟进行比较:结果:实验与模拟结果一致。 C p 与下层与上层的吸收系数比的平方根相关:实验结果支持并验证了 C p 与各层吸收系数比平方根相关性的理论预测。此外,实验还发现在噪声区域的入口处存在一个次级断裂点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dependency of crossover point on absorption changes in bilayer diffusion reflection measurements.

Significance: A better understanding of diffusion reflection (DR) behavior may allow it to be used for more noninvasive applications, including the development of in vivo non-damaging techniques, especially for medical topical diagnosis and treatments.

Aim: For a bilayer opaque substance where the attenuation of the upper layer is larger than the attenuation of the lower layer, the DR crossover point ( C p ) is location where the photons coming from the bottom layer start affecting the DR. We aim to study the dependency of the C p on absorption changes in different layers for constant scattering and top layer thickness.

Approach: Monolayer and bilayer optical tissue-like phantoms were prepared and measured using a DR system. The results were compared with Monte Carlo simulations.

Results: There is an agreement between the experiments and the simulations. C p correlates with the square root of the absorption coefficient ratio of the lower layer to the top layer.

Conclusion: The experimental findings support and validate the theoretical prediction describing the dependency of the C p on the square root of the ratio of the layers' absorption coefficients. In addition, a secondary breaking point is suggested to be observed experimentally at the entrance to the noise area.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
期刊最新文献
Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications. Exploring near-infrared autofluorescence properties in parathyroid tissue: an analysis of fresh and paraffin-embedded thyroidectomy specimens. Impact of signal-to-noise ratio and contrast definition on the sensitivity assessment and benchmarking of fluorescence molecular imaging systems. Comparing spatial distributions of ALA-PpIX and indocyanine green in a whole pig brain glioma model using 3D fluorescence cryotomography. Detection properties of indium-111 and IRDye800CW for intraoperative molecular imaging use across tissue phantom models.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1