{"title":"基于设计的稳定性指示高效液相色谱法估算酒石酸依维列汀散剂和片剂的分析质量。","authors":"Shruti Srivastava, Suneela Dhaneshwar, Neha Kawathekar","doi":"10.1002/bmc.5994","DOIUrl":null,"url":null,"abstract":"<p>The present study utilized Analytical Quality by Design (AQbD) approach to develop a stability-indicating high-performance liquid chromatography (HPLC) method for estimating evogliptin tartrate using design expert software. The key parameters were methodically optimized, contours were plotted, and stability was evaluated using various forced degradation conditions. Using an Agilent HPLC system with a photo diode array (PDA) detector along with Fortis C18 column (250 × 4.6 mm, 5 μm) effectively separated the drug from its degradants. The mobile phase used was methanol: water (pH adjusted to 3.0, 76:24; <i>v/v</i>) at 0.8 mL/min flow rate. Evogliptin was eluted at 2.98 min, at a detection wavelength of 267 nm. The proposed method was found to be specific, precise, linear and robust. The drug was sensitive to acidic, basic, oxidative, thermal, and photodegradation resolving six degradation products. Thus, the developed AQbD-based stability-indicating HPLC method is applicable in analyzing evogliptin in bulk, tablet dosage form and stability samples.</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"38 11","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analytical quality by design-based stability-indicating high performance liquid chromatography method for the estimation of evogliptin tartrate in bulk and tablet dosage form\",\"authors\":\"Shruti Srivastava, Suneela Dhaneshwar, Neha Kawathekar\",\"doi\":\"10.1002/bmc.5994\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The present study utilized Analytical Quality by Design (AQbD) approach to develop a stability-indicating high-performance liquid chromatography (HPLC) method for estimating evogliptin tartrate using design expert software. The key parameters were methodically optimized, contours were plotted, and stability was evaluated using various forced degradation conditions. Using an Agilent HPLC system with a photo diode array (PDA) detector along with Fortis C18 column (250 × 4.6 mm, 5 μm) effectively separated the drug from its degradants. The mobile phase used was methanol: water (pH adjusted to 3.0, 76:24; <i>v/v</i>) at 0.8 mL/min flow rate. Evogliptin was eluted at 2.98 min, at a detection wavelength of 267 nm. The proposed method was found to be specific, precise, linear and robust. The drug was sensitive to acidic, basic, oxidative, thermal, and photodegradation resolving six degradation products. Thus, the developed AQbD-based stability-indicating HPLC method is applicable in analyzing evogliptin in bulk, tablet dosage form and stability samples.</p>\",\"PeriodicalId\":8861,\"journal\":{\"name\":\"Biomedical Chromatography\",\"volume\":\"38 11\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Chromatography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bmc.5994\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.5994","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Analytical quality by design-based stability-indicating high performance liquid chromatography method for the estimation of evogliptin tartrate in bulk and tablet dosage form
The present study utilized Analytical Quality by Design (AQbD) approach to develop a stability-indicating high-performance liquid chromatography (HPLC) method for estimating evogliptin tartrate using design expert software. The key parameters were methodically optimized, contours were plotted, and stability was evaluated using various forced degradation conditions. Using an Agilent HPLC system with a photo diode array (PDA) detector along with Fortis C18 column (250 × 4.6 mm, 5 μm) effectively separated the drug from its degradants. The mobile phase used was methanol: water (pH adjusted to 3.0, 76:24; v/v) at 0.8 mL/min flow rate. Evogliptin was eluted at 2.98 min, at a detection wavelength of 267 nm. The proposed method was found to be specific, precise, linear and robust. The drug was sensitive to acidic, basic, oxidative, thermal, and photodegradation resolving six degradation products. Thus, the developed AQbD-based stability-indicating HPLC method is applicable in analyzing evogliptin in bulk, tablet dosage form and stability samples.
期刊介绍:
Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.