Juferdy Kurniawan, Billy Stinggo Paskharan Siahaan
{"title":"通过 100 赫兹振动控制瞬态弹性成像测量脾脏硬度、肝脏硬度、APRI 评分及其组合预测肝硬化食管静脉曲张的性能。","authors":"Juferdy Kurniawan, Billy Stinggo Paskharan Siahaan","doi":"10.1016/j.clinre.2024.102456","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Oesophageal varices (EV) rupture remains one of the most severe complications of cirrhosis. As the gold standard to predict this accident, esophagogastroduodenoscopy (EGD) itself also has a weakness. Not all patients are convenient with this modality in clinical practice apart from the risk and cost burden. Hence, the search for other non-invasive modalities with high accuracy is still noteworthy. Among them, spleen stiffness measurement (SSM) with 100 Hz probe, liver stiffness measurement (LSM), and the aspartate amino transferase to platelet ratio index (APRI) score became popular and intensively studied with good accuracy, but the results remain conflicting. This study aims to investigate the performance of SSM, LSM, APRI score, and their combination especially as a screening tool for predicting EV in liver cirrhosis patients.</p></div><div><h3>Methods</h3><p>In this cross-sectional study, we included 141 patients with liver cirrhosis who had undergone endoscopy, SSM, LSM, and APRI score calculation between January and March 2023 were enrolled. Diagnostic accuracy was assessed by the area under the receiver-operator curve (AUC). Transient elastography (TE) measurement was performed using a spleen-dedicated FibroScan with a 100-Hz probe.</p></div><div><h3>Results</h3><p>Of the 141 patients, the most common aetiology was hepatitis B in 71 patients (50.4 %). EV were found in 116 patients. Using the AUC, SSM at a cutoff of 40 kPa had the best performance with an AUC of 0.892 (CI 95 %: 0.814–0.969, <em>p</em> <0.0001), with sensitivity 88.79 % and specificity 80 %). Meanwhile, LSM and APRI score had an AUC of 0.832 (CI 95 %: 0.742–0.922, <em>p</em> <0.0001) and 0.780 (CI 95 %: 0.660–0.900, <em>p</em> <0.0001), respectively. The combination of all measurement tools did not show better performance than SSM alone with an AUC of 0.892 (CI 95 %: 0.802–0.982, <em>P</em> <0.0001)</p></div><div><h3>Conclusion</h3><p>SSM provides better performance than LSM and APRI scores for predicting EV. Performance of SSM alone is non-inferior compare to multiple diagnostic tools combined.</p></div>","PeriodicalId":10424,"journal":{"name":"Clinics and research in hepatology and gastroenterology","volume":"48 8","pages":"Article 102456"},"PeriodicalIF":2.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of spleen stiffness measurement by 100‐Hz vibration‐controlled transient elastography, liver stiffness, APRI score and their combination for predicting oesophageal varices in liver cirrhosis\",\"authors\":\"Juferdy Kurniawan, Billy Stinggo Paskharan Siahaan\",\"doi\":\"10.1016/j.clinre.2024.102456\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Oesophageal varices (EV) rupture remains one of the most severe complications of cirrhosis. As the gold standard to predict this accident, esophagogastroduodenoscopy (EGD) itself also has a weakness. Not all patients are convenient with this modality in clinical practice apart from the risk and cost burden. Hence, the search for other non-invasive modalities with high accuracy is still noteworthy. Among them, spleen stiffness measurement (SSM) with 100 Hz probe, liver stiffness measurement (LSM), and the aspartate amino transferase to platelet ratio index (APRI) score became popular and intensively studied with good accuracy, but the results remain conflicting. This study aims to investigate the performance of SSM, LSM, APRI score, and their combination especially as a screening tool for predicting EV in liver cirrhosis patients.</p></div><div><h3>Methods</h3><p>In this cross-sectional study, we included 141 patients with liver cirrhosis who had undergone endoscopy, SSM, LSM, and APRI score calculation between January and March 2023 were enrolled. Diagnostic accuracy was assessed by the area under the receiver-operator curve (AUC). Transient elastography (TE) measurement was performed using a spleen-dedicated FibroScan with a 100-Hz probe.</p></div><div><h3>Results</h3><p>Of the 141 patients, the most common aetiology was hepatitis B in 71 patients (50.4 %). EV were found in 116 patients. Using the AUC, SSM at a cutoff of 40 kPa had the best performance with an AUC of 0.892 (CI 95 %: 0.814–0.969, <em>p</em> <0.0001), with sensitivity 88.79 % and specificity 80 %). Meanwhile, LSM and APRI score had an AUC of 0.832 (CI 95 %: 0.742–0.922, <em>p</em> <0.0001) and 0.780 (CI 95 %: 0.660–0.900, <em>p</em> <0.0001), respectively. The combination of all measurement tools did not show better performance than SSM alone with an AUC of 0.892 (CI 95 %: 0.802–0.982, <em>P</em> <0.0001)</p></div><div><h3>Conclusion</h3><p>SSM provides better performance than LSM and APRI scores for predicting EV. Performance of SSM alone is non-inferior compare to multiple diagnostic tools combined.</p></div>\",\"PeriodicalId\":10424,\"journal\":{\"name\":\"Clinics and research in hepatology and gastroenterology\",\"volume\":\"48 8\",\"pages\":\"Article 102456\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinics and research in hepatology and gastroenterology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2210740124001773\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics and research in hepatology and gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2210740124001773","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Performance of spleen stiffness measurement by 100‐Hz vibration‐controlled transient elastography, liver stiffness, APRI score and their combination for predicting oesophageal varices in liver cirrhosis
Background
Oesophageal varices (EV) rupture remains one of the most severe complications of cirrhosis. As the gold standard to predict this accident, esophagogastroduodenoscopy (EGD) itself also has a weakness. Not all patients are convenient with this modality in clinical practice apart from the risk and cost burden. Hence, the search for other non-invasive modalities with high accuracy is still noteworthy. Among them, spleen stiffness measurement (SSM) with 100 Hz probe, liver stiffness measurement (LSM), and the aspartate amino transferase to platelet ratio index (APRI) score became popular and intensively studied with good accuracy, but the results remain conflicting. This study aims to investigate the performance of SSM, LSM, APRI score, and their combination especially as a screening tool for predicting EV in liver cirrhosis patients.
Methods
In this cross-sectional study, we included 141 patients with liver cirrhosis who had undergone endoscopy, SSM, LSM, and APRI score calculation between January and March 2023 were enrolled. Diagnostic accuracy was assessed by the area under the receiver-operator curve (AUC). Transient elastography (TE) measurement was performed using a spleen-dedicated FibroScan with a 100-Hz probe.
Results
Of the 141 patients, the most common aetiology was hepatitis B in 71 patients (50.4 %). EV were found in 116 patients. Using the AUC, SSM at a cutoff of 40 kPa had the best performance with an AUC of 0.892 (CI 95 %: 0.814–0.969, p <0.0001), with sensitivity 88.79 % and specificity 80 %). Meanwhile, LSM and APRI score had an AUC of 0.832 (CI 95 %: 0.742–0.922, p <0.0001) and 0.780 (CI 95 %: 0.660–0.900, p <0.0001), respectively. The combination of all measurement tools did not show better performance than SSM alone with an AUC of 0.892 (CI 95 %: 0.802–0.982, P <0.0001)
Conclusion
SSM provides better performance than LSM and APRI scores for predicting EV. Performance of SSM alone is non-inferior compare to multiple diagnostic tools combined.
期刊介绍:
Clinics and Research in Hepatology and Gastroenterology publishes high-quality original research papers in the field of hepatology and gastroenterology. The editors put the accent on rapid communication of new research and clinical developments and so called "hot topic" issues. Following a clear Editorial line, besides original articles and case reports, each issue features editorials, commentaries and reviews. The journal encourages research and discussion between all those involved in the specialty on an international level. All articles are peer reviewed by international experts, the articles in press are online and indexed in the international databases (Current Contents, Pubmed, Scopus, Science Direct).
Clinics and Research in Hepatology and Gastroenterology is a subscription journal (with optional open access), which allows you to publish your research without any cost to you (unless you proactively chose the open access option). Your article will be available to all researchers around the globe whose institution has a subscription to the journal.