利用 CareLink 个人数据管理系统生成有关糖尿病技术的真实证据。

IF 5.4 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes, Obesity & Metabolism Pub Date : 2024-09-04 DOI:10.1111/dom.15868
Tim van den Heuvel, Javier Castañeda, Arcelia Arrieta, Benedikt Voelker, Ohad Cohen, Margaret Liu, Franck Diaz Garelli, John Shin
{"title":"利用 CareLink 个人数据管理系统生成有关糖尿病技术的真实证据。","authors":"Tim van den Heuvel, Javier Castañeda, Arcelia Arrieta, Benedikt Voelker, Ohad Cohen, Margaret Liu, Franck Diaz Garelli, John Shin","doi":"10.1111/dom.15868","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To establish trust in real-world evidence (RWE) derived from CareLink Personal (CP), Medtronic's data management system for MiniMed system users, we show that this database and its analyses strictly adhere to the principles of RWE.</p><p><strong>Methods: </strong>The methodology is applicable to all MiniMed iterations. We described every step from raw data to predefined outcomes. In addition, we showed CP's fitness-for-research by the below metrics (using last year's MiniMed 780G system data as a case study): representative population, relevant endpoints, appropriate granularity, high data completeness, high data representativity and consistency in results.</p><p><strong>Results: </strong>The process from raw data to outcomes has been validated, and metrics/logics adhere to established definitions. Over 95% of users have a CP account; with 96% providing consent, this allows the use of >91% of the census population. There is no rationale for an over-representation of a specific phenotype among users not included. CP includes >50 endpoints, including 'International Consensus on Time in Range' based metrics. Data are recorded at 5-min intervals (maximum 288 per day), and on average there were 263 data points per person per day. Ninety-nine per cent of uploads were automated. For the last year, only 1 in 6 users had a data gap >1 day, and 1 in 50 had a gap >1 week. The time in range from in-silico studies was similar to that of real-world studies from different geographies and with ever growing populations.</p><p><strong>Conclusion: </strong>RWE from CP adheres to the principles of RWE and can serve as robust evidence on the performance and safety of MiniMed systems.</p>","PeriodicalId":158,"journal":{"name":"Diabetes, Obesity & Metabolism","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Generating real-world evidence on diabetes technology using the CareLink Personal data management system.\",\"authors\":\"Tim van den Heuvel, Javier Castañeda, Arcelia Arrieta, Benedikt Voelker, Ohad Cohen, Margaret Liu, Franck Diaz Garelli, John Shin\",\"doi\":\"10.1111/dom.15868\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To establish trust in real-world evidence (RWE) derived from CareLink Personal (CP), Medtronic's data management system for MiniMed system users, we show that this database and its analyses strictly adhere to the principles of RWE.</p><p><strong>Methods: </strong>The methodology is applicable to all MiniMed iterations. We described every step from raw data to predefined outcomes. In addition, we showed CP's fitness-for-research by the below metrics (using last year's MiniMed 780G system data as a case study): representative population, relevant endpoints, appropriate granularity, high data completeness, high data representativity and consistency in results.</p><p><strong>Results: </strong>The process from raw data to outcomes has been validated, and metrics/logics adhere to established definitions. Over 95% of users have a CP account; with 96% providing consent, this allows the use of >91% of the census population. There is no rationale for an over-representation of a specific phenotype among users not included. CP includes >50 endpoints, including 'International Consensus on Time in Range' based metrics. Data are recorded at 5-min intervals (maximum 288 per day), and on average there were 263 data points per person per day. Ninety-nine per cent of uploads were automated. For the last year, only 1 in 6 users had a data gap >1 day, and 1 in 50 had a gap >1 week. The time in range from in-silico studies was similar to that of real-world studies from different geographies and with ever growing populations.</p><p><strong>Conclusion: </strong>RWE from CP adheres to the principles of RWE and can serve as robust evidence on the performance and safety of MiniMed systems.</p>\",\"PeriodicalId\":158,\"journal\":{\"name\":\"Diabetes, Obesity & Metabolism\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-09-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes, Obesity & Metabolism\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/dom.15868\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes, Obesity & Metabolism","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/dom.15868","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

目的:为了建立对来自美敦力为 MiniMed 系统用户提供的数据管理系统 CareLink Personal (CP) 的真实世界证据 (RWE) 的信任,我们证明该数据库及其分析严格遵守 RWE 原则:该方法适用于 MiniMed 的所有迭代。我们描述了从原始数据到预定义结果的每一个步骤。此外,我们还通过以下指标(以去年的 MiniMed 780G 系统数据为例)说明了 CP 的研究适用性:具有代表性的人群、相关终点、适当的粒度、高数据完整性、高数据代表性和结果一致性:结果:从原始数据到结果的过程已经过验证,指标/逻辑符合既定定义。超过 95% 的用户拥有 CP 帐户;96% 的用户表示同意,因此可以使用超过 91% 的普查人口。在未纳入的用户中,不存在特定表型代表性过高的理由。CP 包括 >50 个终点,其中包括基于 "范围内时间国际共识 "的指标。数据以 5 分钟为间隔记录(每天最多 288 个),平均每人每天有 263 个数据点。99% 的上传是自动完成的。去年,每 6 个用户中只有 1 个用户的数据间隙大于 1 天,每 50 个用户中只有 1 个用户的数据间隙大于 1 周。来自实验室研究的数据间隔时间与来自不同地区、人口不断增长的真实世界研究的数据间隔时间相似:结论:CP 的 RWE 符合 RWE 原则,可作为 MiniMed 系统性能和安全性的有力证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Generating real-world evidence on diabetes technology using the CareLink Personal data management system.

Aim: To establish trust in real-world evidence (RWE) derived from CareLink Personal (CP), Medtronic's data management system for MiniMed system users, we show that this database and its analyses strictly adhere to the principles of RWE.

Methods: The methodology is applicable to all MiniMed iterations. We described every step from raw data to predefined outcomes. In addition, we showed CP's fitness-for-research by the below metrics (using last year's MiniMed 780G system data as a case study): representative population, relevant endpoints, appropriate granularity, high data completeness, high data representativity and consistency in results.

Results: The process from raw data to outcomes has been validated, and metrics/logics adhere to established definitions. Over 95% of users have a CP account; with 96% providing consent, this allows the use of >91% of the census population. There is no rationale for an over-representation of a specific phenotype among users not included. CP includes >50 endpoints, including 'International Consensus on Time in Range' based metrics. Data are recorded at 5-min intervals (maximum 288 per day), and on average there were 263 data points per person per day. Ninety-nine per cent of uploads were automated. For the last year, only 1 in 6 users had a data gap >1 day, and 1 in 50 had a gap >1 week. The time in range from in-silico studies was similar to that of real-world studies from different geographies and with ever growing populations.

Conclusion: RWE from CP adheres to the principles of RWE and can serve as robust evidence on the performance and safety of MiniMed systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diabetes, Obesity & Metabolism
Diabetes, Obesity & Metabolism 医学-内分泌学与代谢
CiteScore
10.90
自引率
6.90%
发文量
319
审稿时长
3-8 weeks
期刊介绍: Diabetes, Obesity and Metabolism is primarily a journal of clinical and experimental pharmacology and therapeutics covering the interrelated areas of diabetes, obesity and metabolism. The journal prioritises high-quality original research that reports on the effects of new or existing therapies, including dietary, exercise and lifestyle (non-pharmacological) interventions, in any aspect of metabolic and endocrine disease, either in humans or animal and cellular systems. ‘Metabolism’ may relate to lipids, bone and drug metabolism, or broader aspects of endocrine dysfunction. Preclinical pharmacology, pharmacokinetic studies, meta-analyses and those addressing drug safety and tolerability are also highly suitable for publication in this journal. Original research may be published as a main paper or as a research letter.
期刊最新文献
Continuous ketone monitoring: Exciting implications for clinical practice. Cofrogliptin once every 2 weeks as add-on therapy to metformin versus daily linagliptin in patients with type 2 diabetes in China: A randomized, double-blind, non-inferiority trial. Changes in insulin utilization in China from 2020 to 2022. Visceral and subcutaneous adiposity and cardiovascular disease: Unravelling associations and prognostic value. A novel, centrally acting mammalian aminosterol, ENT-03, induces weight loss in obese and lean rodents.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1