Royston K Y Tan, Gim Yew Ng, Tin A Tun, Fabian A Braeu, Monisha E Nongpiur, Tin Aung, Michaël J A Girard
{"title":"影响瞳孔放大时夹角的虹膜形态和生物力学因素","authors":"Royston K Y Tan, Gim Yew Ng, Tin A Tun, Fabian A Braeu, Monisha E Nongpiur, Tin Aung, Michaël J A Girard","doi":"10.1167/iovs.65.11.7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To use finite element (FE) analysis to assess what morphologic and biomechanical factors of the iris and anterior chamber are more likely to influence angle narrowing during pupil dilation.</p><p><strong>Methods: </strong>The study consisted of 1344 FE models comprising the cornea, sclera, lens, and iris to simulate pupil dilation. For each model, we varied the following parameters: anterior chamber depth (ACD = 2-4 mm) and anterior chamber width (ACW = 10-12 mm), iris convexity (IC = 0-0.3 mm), iris thickness (IT = 0.3-0.5 mm), stiffness (E = 4-24 kPa), and Poisson's ratio (v = 0-0.3). We evaluated the change in (△∠) and the final dilated angles (∠f) from baseline to dilation for each parameter.</p><p><strong>Results: </strong>The final dilated angles decreased with a smaller ACD (∠f = 53.4° ± 12.3° to 21.3° ± 14.9°), smaller ACW (∠f = 48.2° ± 13.5° to 26.2° ± 18.2°), larger IT (∠f = 52.6° ± 12.3° to 24.4° ± 15.1°), larger IC (∠f = 45.0° ± 19.2° to 33.9° ± 16.5°), larger E (∠f = 40.3° ± 17.3° to 37.4° ± 19.2°), and larger v (∠f = 42.7° ± 17.7° to 34.2° ± 18.1°). The change in angles increased with larger ACD (△∠ = 9.37° ± 11.1° to 15.4° ± 9.3°), smaller ACW (△∠ = 7.4° ± 6.8° to 16.4° ± 11.5°), larger IT (△∠ = 5.3° ± 7.1° to 19.3° ± 10.2°), smaller IC (△∠ = 5.4° ± 8.2° to 19.5° ± 10.2°), larger E (△∠ = 10.9° ± 12.2° to 13.1° ± 8.8°), and larger v (△∠ = 8.1° ± 9.4° to 16.6° ± 10.4°).</p><p><strong>Conclusions: </strong>The morphology of the iris (IT and IC) and its innate biomechanical behavior (E and v) were crucial in influencing the way the iris deformed during dilation, and angle closure was further exacerbated by decreased anterior chamber biometry (ACD and ACW).</p>","PeriodicalId":14620,"journal":{"name":"Investigative ophthalmology & visual science","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379082/pdf/","citationCount":"0","resultStr":"{\"title\":\"Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation.\",\"authors\":\"Royston K Y Tan, Gim Yew Ng, Tin A Tun, Fabian A Braeu, Monisha E Nongpiur, Tin Aung, Michaël J A Girard\",\"doi\":\"10.1167/iovs.65.11.7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To use finite element (FE) analysis to assess what morphologic and biomechanical factors of the iris and anterior chamber are more likely to influence angle narrowing during pupil dilation.</p><p><strong>Methods: </strong>The study consisted of 1344 FE models comprising the cornea, sclera, lens, and iris to simulate pupil dilation. For each model, we varied the following parameters: anterior chamber depth (ACD = 2-4 mm) and anterior chamber width (ACW = 10-12 mm), iris convexity (IC = 0-0.3 mm), iris thickness (IT = 0.3-0.5 mm), stiffness (E = 4-24 kPa), and Poisson's ratio (v = 0-0.3). We evaluated the change in (△∠) and the final dilated angles (∠f) from baseline to dilation for each parameter.</p><p><strong>Results: </strong>The final dilated angles decreased with a smaller ACD (∠f = 53.4° ± 12.3° to 21.3° ± 14.9°), smaller ACW (∠f = 48.2° ± 13.5° to 26.2° ± 18.2°), larger IT (∠f = 52.6° ± 12.3° to 24.4° ± 15.1°), larger IC (∠f = 45.0° ± 19.2° to 33.9° ± 16.5°), larger E (∠f = 40.3° ± 17.3° to 37.4° ± 19.2°), and larger v (∠f = 42.7° ± 17.7° to 34.2° ± 18.1°). The change in angles increased with larger ACD (△∠ = 9.37° ± 11.1° to 15.4° ± 9.3°), smaller ACW (△∠ = 7.4° ± 6.8° to 16.4° ± 11.5°), larger IT (△∠ = 5.3° ± 7.1° to 19.3° ± 10.2°), smaller IC (△∠ = 5.4° ± 8.2° to 19.5° ± 10.2°), larger E (△∠ = 10.9° ± 12.2° to 13.1° ± 8.8°), and larger v (△∠ = 8.1° ± 9.4° to 16.6° ± 10.4°).</p><p><strong>Conclusions: </strong>The morphology of the iris (IT and IC) and its innate biomechanical behavior (E and v) were crucial in influencing the way the iris deformed during dilation, and angle closure was further exacerbated by decreased anterior chamber biometry (ACD and ACW).</p>\",\"PeriodicalId\":14620,\"journal\":{\"name\":\"Investigative ophthalmology & visual science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379082/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Investigative ophthalmology & visual science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1167/iovs.65.11.7\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative ophthalmology & visual science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1167/iovs.65.11.7","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation.
Purpose: To use finite element (FE) analysis to assess what morphologic and biomechanical factors of the iris and anterior chamber are more likely to influence angle narrowing during pupil dilation.
Methods: The study consisted of 1344 FE models comprising the cornea, sclera, lens, and iris to simulate pupil dilation. For each model, we varied the following parameters: anterior chamber depth (ACD = 2-4 mm) and anterior chamber width (ACW = 10-12 mm), iris convexity (IC = 0-0.3 mm), iris thickness (IT = 0.3-0.5 mm), stiffness (E = 4-24 kPa), and Poisson's ratio (v = 0-0.3). We evaluated the change in (△∠) and the final dilated angles (∠f) from baseline to dilation for each parameter.
Results: The final dilated angles decreased with a smaller ACD (∠f = 53.4° ± 12.3° to 21.3° ± 14.9°), smaller ACW (∠f = 48.2° ± 13.5° to 26.2° ± 18.2°), larger IT (∠f = 52.6° ± 12.3° to 24.4° ± 15.1°), larger IC (∠f = 45.0° ± 19.2° to 33.9° ± 16.5°), larger E (∠f = 40.3° ± 17.3° to 37.4° ± 19.2°), and larger v (∠f = 42.7° ± 17.7° to 34.2° ± 18.1°). The change in angles increased with larger ACD (△∠ = 9.37° ± 11.1° to 15.4° ± 9.3°), smaller ACW (△∠ = 7.4° ± 6.8° to 16.4° ± 11.5°), larger IT (△∠ = 5.3° ± 7.1° to 19.3° ± 10.2°), smaller IC (△∠ = 5.4° ± 8.2° to 19.5° ± 10.2°), larger E (△∠ = 10.9° ± 12.2° to 13.1° ± 8.8°), and larger v (△∠ = 8.1° ± 9.4° to 16.6° ± 10.4°).
Conclusions: The morphology of the iris (IT and IC) and its innate biomechanical behavior (E and v) were crucial in influencing the way the iris deformed during dilation, and angle closure was further exacerbated by decreased anterior chamber biometry (ACD and ACW).
期刊介绍:
Investigative Ophthalmology & Visual Science (IOVS), published as ready online, is a peer-reviewed academic journal of the Association for Research in Vision and Ophthalmology (ARVO). IOVS features original research, mostly pertaining to clinical and laboratory ophthalmology and vision research in general.