反应性心肌缺血时冠状动脉内心电图 ST 段偏移缓解时间(Τ-icECG):评估血流动力学冠状动脉狭窄严重程度的新方法。

IF 4.1 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS American journal of physiology. Heart and circulatory physiology Pub Date : 2024-10-01 Epub Date: 2024-09-06 DOI:10.1152/ajpheart.00481.2024
Marius Reto Bigler, Andrea Kieninger-Gräfitsch, Miklos Rohla, Noé Corpateaux, Frédéric Waldmann, Reto Wildhaber, Jonas Häner, Christian Seiler
{"title":"反应性心肌缺血时冠状动脉内心电图 ST 段偏移缓解时间(Τ-icECG):评估血流动力学冠状动脉狭窄严重程度的新方法。","authors":"Marius Reto Bigler, Andrea Kieninger-Gräfitsch, Miklos Rohla, Noé Corpateaux, Frédéric Waldmann, Reto Wildhaber, Jonas Häner, Christian Seiler","doi":"10.1152/ajpheart.00481.2024","DOIUrl":null,"url":null,"abstract":"<p><p>Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis. This retrospective, observational study included patients with chronic coronary syndrome undergoing hemodynamic coronary stenosis assessment immediately following a strictly 1-min proximal coronary artery balloon occlusion with simultaneous icECG recording. icECG was used for a beat-to-beat analysis of the ST-segment shift during reactive hyperemia immediately following balloon deflation. The time from coronary balloon deflation until the ST-segment shift reached 37% of its maximum level, i.e., icECG ST-segment shift remission time (τ-icECG in seconds), was obtained by an automatic algorithm. τ-icECG was tested against the simultaneously obtained reactive hyperemia FFR at a threshold of 0.80 as a reference parameter. From 120 patients, 139 icECGs (age, 68 ± 10 yr old) were analyzed. Receiver operating characteristic (ROC) analysis of τ-icECG for the detection of hemodynamically relevant coronary stenosis at an FFR of ≤0.80 was performed. The area under the ROC curve was equal to 0.621 (<i>P</i> = 0.0363) at an optimal τ-icECG threshold of 8 s (sensitivity, 61%; specificity, 67%). τ-icECG correlated inversely and linearly with FFR (<i>P</i> = 0.0327). This first proof-of-concept study demonstrates that τ-icECG, a measure of icECG ST segment-shift remission after a 1-min coronary artery balloon occlusion accurately detects hemodynamically relevant coronary artery stenosis according to FFR at a threshold of ≥8 s.<b>NEW & NOTEWORTHY</b> Invasive hemodynamic measurements are recommended by the current cardiology guidelines to guide percutaneous coronary interventions in the setting of chronic coronary syndrome. However, those pressure-derived indices demonstrate several theoretical and practical limitations. Thus, this study demonstrates the accuracy of a novel, pathophysiology-driven approach using intracoronary ECG for the identification of hemodynamically relevant coronary lesions by quantitatively assessing myocardial ischemia remission.</p>","PeriodicalId":7692,"journal":{"name":"American journal of physiology. Heart and circulatory physiology","volume":" ","pages":"H1124-H1131"},"PeriodicalIF":4.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482267/pdf/","citationCount":"0","resultStr":"{\"title\":\"Intracoronary ECG ST-segment shift remission time during reactive myocardial hyperemia: a new method to assess hemodynamic coronary stenosis severity.\",\"authors\":\"Marius Reto Bigler, Andrea Kieninger-Gräfitsch, Miklos Rohla, Noé Corpateaux, Frédéric Waldmann, Reto Wildhaber, Jonas Häner, Christian Seiler\",\"doi\":\"10.1152/ajpheart.00481.2024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis. This retrospective, observational study included patients with chronic coronary syndrome undergoing hemodynamic coronary stenosis assessment immediately following a strictly 1-min proximal coronary artery balloon occlusion with simultaneous icECG recording. icECG was used for a beat-to-beat analysis of the ST-segment shift during reactive hyperemia immediately following balloon deflation. The time from coronary balloon deflation until the ST-segment shift reached 37% of its maximum level, i.e., icECG ST-segment shift remission time (τ-icECG in seconds), was obtained by an automatic algorithm. τ-icECG was tested against the simultaneously obtained reactive hyperemia FFR at a threshold of 0.80 as a reference parameter. From 120 patients, 139 icECGs (age, 68 ± 10 yr old) were analyzed. Receiver operating characteristic (ROC) analysis of τ-icECG for the detection of hemodynamically relevant coronary stenosis at an FFR of ≤0.80 was performed. The area under the ROC curve was equal to 0.621 (<i>P</i> = 0.0363) at an optimal τ-icECG threshold of 8 s (sensitivity, 61%; specificity, 67%). τ-icECG correlated inversely and linearly with FFR (<i>P</i> = 0.0327). This first proof-of-concept study demonstrates that τ-icECG, a measure of icECG ST segment-shift remission after a 1-min coronary artery balloon occlusion accurately detects hemodynamically relevant coronary artery stenosis according to FFR at a threshold of ≥8 s.<b>NEW & NOTEWORTHY</b> Invasive hemodynamic measurements are recommended by the current cardiology guidelines to guide percutaneous coronary interventions in the setting of chronic coronary syndrome. However, those pressure-derived indices demonstrate several theoretical and practical limitations. Thus, this study demonstrates the accuracy of a novel, pathophysiology-driven approach using intracoronary ECG for the identification of hemodynamically relevant coronary lesions by quantitatively assessing myocardial ischemia remission.</p>\",\"PeriodicalId\":7692,\"journal\":{\"name\":\"American journal of physiology. Heart and circulatory physiology\",\"volume\":\" \",\"pages\":\"H1124-H1131\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482267/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of physiology. Heart and circulatory physiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1152/ajpheart.00481.2024\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of physiology. Heart and circulatory physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/ajpheart.00481.2024","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景-分数血流储备(FFR)测量被推荐用于评估血流动力学冠状动脉狭窄的严重程度。冠状动脉内心电图(icECG)很容易获得,而且由于其靠近心肌,在检测心肌缺血方面具有很高的灵敏度。我们假设,控制性冠状动脉闭塞后心肌缺血在 icECG 上的缓解时间能准确检测出与血流动力学相关的冠状动脉狭窄。方法--这项回顾性观察研究纳入了慢性冠状动脉综合征患者,他们在严格的 1 分钟冠状动脉近端球囊闭塞后立即接受了血流动力学冠状动脉狭窄评估,并同时进行了 icECG 记录。在球囊放气后立即使用 IcECG 对反应性充血时的 ST 段移动进行逐次分析。τ-icECG与同时获得的反应性充血FFR进行对比测试,以0.80为阈值作为参考参数。结果--分析了 120 名患者(年龄为 68±10 岁)的 139 张 icECG。对 FFR ≤0.80 时检测血流动力学相关冠状动脉狭窄的 τ-icECG 进行了接收器操作特征(ROC)分析。τ-icECG与FFR成反比线性相关(p=0.0327)。结论--这项首次概念验证研究表明,τ-icECG 是在 1 分钟冠状动脉球囊闭塞后测量 icECG ST 段移位缓解情况的一种方法,它能根据≥8 秒阈值的 FFR 准确检测出与血流动力学相关的冠状动脉狭窄。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intracoronary ECG ST-segment shift remission time during reactive myocardial hyperemia: a new method to assess hemodynamic coronary stenosis severity.

Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis. This retrospective, observational study included patients with chronic coronary syndrome undergoing hemodynamic coronary stenosis assessment immediately following a strictly 1-min proximal coronary artery balloon occlusion with simultaneous icECG recording. icECG was used for a beat-to-beat analysis of the ST-segment shift during reactive hyperemia immediately following balloon deflation. The time from coronary balloon deflation until the ST-segment shift reached 37% of its maximum level, i.e., icECG ST-segment shift remission time (τ-icECG in seconds), was obtained by an automatic algorithm. τ-icECG was tested against the simultaneously obtained reactive hyperemia FFR at a threshold of 0.80 as a reference parameter. From 120 patients, 139 icECGs (age, 68 ± 10 yr old) were analyzed. Receiver operating characteristic (ROC) analysis of τ-icECG for the detection of hemodynamically relevant coronary stenosis at an FFR of ≤0.80 was performed. The area under the ROC curve was equal to 0.621 (P = 0.0363) at an optimal τ-icECG threshold of 8 s (sensitivity, 61%; specificity, 67%). τ-icECG correlated inversely and linearly with FFR (P = 0.0327). This first proof-of-concept study demonstrates that τ-icECG, a measure of icECG ST segment-shift remission after a 1-min coronary artery balloon occlusion accurately detects hemodynamically relevant coronary artery stenosis according to FFR at a threshold of ≥8 s.NEW & NOTEWORTHY Invasive hemodynamic measurements are recommended by the current cardiology guidelines to guide percutaneous coronary interventions in the setting of chronic coronary syndrome. However, those pressure-derived indices demonstrate several theoretical and practical limitations. Thus, this study demonstrates the accuracy of a novel, pathophysiology-driven approach using intracoronary ECG for the identification of hemodynamically relevant coronary lesions by quantitatively assessing myocardial ischemia remission.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.60
自引率
10.40%
发文量
202
审稿时长
2-4 weeks
期刊介绍: The American Journal of Physiology-Heart and Circulatory Physiology publishes original investigations, reviews and perspectives on the physiology of the heart, vasculature, and lymphatics. These articles include experimental and theoretical studies of cardiovascular function at all levels of organization ranging from the intact and integrative animal and organ function to the cellular, subcellular, and molecular levels. The journal embraces new descriptions of these functions and their control systems, as well as their basis in biochemistry, biophysics, genetics, and cell biology. Preference is given to research that provides significant new mechanistic physiological insights that determine the performance of the normal and abnormal heart and circulation.
期刊最新文献
The role of T cells in vascular aging, hypertension, and atherosclerosis. A zebrafish model to study RRAGD variants associated cardiomyopathy. Acceleration of age-related impairments in vascular function in women: interrogation of the (un)usual hormonal suspects. Metabolites and metabolism in vascular calcification: links between adenosine signaling and the methionine cycle. Recent advances associated with cardiometabolic remodeling in diabetes-induced heart failure.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1