未增强图像腰椎骨密度CT频谱测量的准确性和临床实用性:综述。

IF 2.5 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiography Pub Date : 2024-10-01 DOI:10.1016/j.radi.2024.08.009
J. Hepburn, C. Currie, L.C. Trinder
{"title":"未增强图像腰椎骨密度CT频谱测量的准确性和临床实用性:综述。","authors":"J. Hepburn,&nbsp;C. Currie,&nbsp;L.C. Trinder","doi":"10.1016/j.radi.2024.08.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>To review and evaluate available literature on spectral computed tomography (SCT) bone mineral density (BMD) measurement in adult thoracolumbar vertebrae of unenhanced images compared to quantitative computed tomography (QCT), to understand its current clinical utility.</div></div><div><h3>Key findings</h3><div>Keyword searches in four databases identified four cross-sectional studies which acquired an SCT BMD measurement in thoracolumbar vertebrae and compared this respectively to QCT, which were then critically appraised using the AXIS tool for cross-sectional studies. 862 vertebrae were measured between T10-S1 in 368 patients. Three studies demonstrated a statistically significant correlation between SCT and QCT for the measurement of Hydroxyapatite (HAP) and calcium (r = 0.86–0.96). One study demonstrated a diagnostic accuracy of 96% using a receiver operating curve.</div></div><div><h3>Conclusions</h3><div>SCT measurements of HAP and calcium in the lumbar vertebrae are comparable to QCT for patients with no additional pathology present. However, further research is required to evaluate diagnostic accuracy before clinical application.</div></div><div><h3>Implications for practice</h3><div>SCT BMD measurement has the potential to be developed as a screening tool for osteoporosis within the fracture liaison service (FLS). This could aid in the identification of patients with osteoporosis and address the current treatment gap. Nonetheless, many factors must be considered for this application including staff training, radiation protection and patient engagement with the screening programme.</div></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":"30 6","pages":"Pages 1687-1694"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The accuracy and clinical utility of spectral CT bone density measurement in the lumbar spine of unenhanced images: A narrative review\",\"authors\":\"J. Hepburn,&nbsp;C. Currie,&nbsp;L.C. Trinder\",\"doi\":\"10.1016/j.radi.2024.08.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><div>To review and evaluate available literature on spectral computed tomography (SCT) bone mineral density (BMD) measurement in adult thoracolumbar vertebrae of unenhanced images compared to quantitative computed tomography (QCT), to understand its current clinical utility.</div></div><div><h3>Key findings</h3><div>Keyword searches in four databases identified four cross-sectional studies which acquired an SCT BMD measurement in thoracolumbar vertebrae and compared this respectively to QCT, which were then critically appraised using the AXIS tool for cross-sectional studies. 862 vertebrae were measured between T10-S1 in 368 patients. Three studies demonstrated a statistically significant correlation between SCT and QCT for the measurement of Hydroxyapatite (HAP) and calcium (r = 0.86–0.96). One study demonstrated a diagnostic accuracy of 96% using a receiver operating curve.</div></div><div><h3>Conclusions</h3><div>SCT measurements of HAP and calcium in the lumbar vertebrae are comparable to QCT for patients with no additional pathology present. However, further research is required to evaluate diagnostic accuracy before clinical application.</div></div><div><h3>Implications for practice</h3><div>SCT BMD measurement has the potential to be developed as a screening tool for osteoporosis within the fracture liaison service (FLS). This could aid in the identification of patients with osteoporosis and address the current treatment gap. Nonetheless, many factors must be considered for this application including staff training, radiation protection and patient engagement with the screening programme.</div></div>\",\"PeriodicalId\":47416,\"journal\":{\"name\":\"Radiography\",\"volume\":\"30 6\",\"pages\":\"Pages 1687-1694\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1078817424002062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817424002062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的回顾并评估光谱计算机断层扫描(SCT)与定量计算机断层扫描(QCT)对比测量成人胸腰椎未增强图像的骨矿密度(BMD)的现有文献,以了解其目前的临床实用性:在四个数据库中进行关键词搜索后发现了四项横断面研究,这些研究获得了胸腰椎SCT BMD测量结果,并分别与QCT进行了比较,然后使用横断面研究AXIS工具对这些研究进行了严格评估。对 368 名患者 T10-S1 之间的 862 个椎骨进行了测量。三项研究表明,在测量羟磷灰石(HAP)和钙方面,SCT 和 QCT 之间存在统计学意义上的显著相关性(r = 0.86-0.96)。一项研究利用接收者操作曲线显示诊断准确率为 96%:结论:对于没有其他病变的患者,SCT 测量腰椎的 HAP 和钙的结果与 QCT 相当。然而,在临床应用之前,还需要进一步的研究来评估诊断的准确性:SCT BMD 测量有可能发展成为骨折联络服务(FLS)中的骨质疏松症筛查工具。这有助于识别骨质疏松症患者,解决目前的治疗缺口。然而,这一应用必须考虑许多因素,包括人员培训、辐射防护和患者对筛查计划的参与度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The accuracy and clinical utility of spectral CT bone density measurement in the lumbar spine of unenhanced images: A narrative review

Objectives

To review and evaluate available literature on spectral computed tomography (SCT) bone mineral density (BMD) measurement in adult thoracolumbar vertebrae of unenhanced images compared to quantitative computed tomography (QCT), to understand its current clinical utility.

Key findings

Keyword searches in four databases identified four cross-sectional studies which acquired an SCT BMD measurement in thoracolumbar vertebrae and compared this respectively to QCT, which were then critically appraised using the AXIS tool for cross-sectional studies. 862 vertebrae were measured between T10-S1 in 368 patients. Three studies demonstrated a statistically significant correlation between SCT and QCT for the measurement of Hydroxyapatite (HAP) and calcium (r = 0.86–0.96). One study demonstrated a diagnostic accuracy of 96% using a receiver operating curve.

Conclusions

SCT measurements of HAP and calcium in the lumbar vertebrae are comparable to QCT for patients with no additional pathology present. However, further research is required to evaluate diagnostic accuracy before clinical application.

Implications for practice

SCT BMD measurement has the potential to be developed as a screening tool for osteoporosis within the fracture liaison service (FLS). This could aid in the identification of patients with osteoporosis and address the current treatment gap. Nonetheless, many factors must be considered for this application including staff training, radiation protection and patient engagement with the screening programme.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiography
Radiography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍: Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.
期刊最新文献
"I used their criticisms as my weapon to succeed" Experiences in the dual learning environment of Black, Asian, and ethnically diverse therapeutic radiographer undergraduate students - results of a UK survey. Radiographers' perspective of patient safety at ultrasound units in radiology departments. Uniformity test in three-dimensional rotational angiography: Novel tools and methods for advanced performance evaluation. Co-production of a novel intervention targeting obesity-related barriers to mammographic screening participation. Communicating the risk of recall in mammography screening - Enskilment in breast radiography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1