{"title":"评估用于校准皮肤癌诊断热敏电阻特性的真空绝热温度校准装置","authors":"Homei Fujita, Takashi Nonaka, Yasushi Hosokawa, Takuma Kogawa, Fuhui Guo, Yuya Iseki, Miyo Yokota, Takahiro Okabe, Shigenao Maruyama","doi":"10.1002/eej.23471","DOIUrl":null,"url":null,"abstract":"<p>Recent methods using thermistors as an early detection of skin cancer require the higher resolution of 5 mK. Previously, the authors developed a vacuum insulated temperature device that calibrates the resistance temperature characteristics of thermistors, so that it improves the temperature resolution and accuracy of skin cancer diagnosis. In this study, the operational methods of the calibration system were compared for improving further accuracy using the temperature calibration device and the oil tank calibration device. The results of the comparison indicated that the temperature calibration device is probably as accurate as the oil tank calibration device.</p>","PeriodicalId":50550,"journal":{"name":"Electrical Engineering in Japan","volume":"217 3","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a vacuum insulated temperature calibration device to calibrate thermistor characteristics for skin cancer diagnosis\",\"authors\":\"Homei Fujita, Takashi Nonaka, Yasushi Hosokawa, Takuma Kogawa, Fuhui Guo, Yuya Iseki, Miyo Yokota, Takahiro Okabe, Shigenao Maruyama\",\"doi\":\"10.1002/eej.23471\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Recent methods using thermistors as an early detection of skin cancer require the higher resolution of 5 mK. Previously, the authors developed a vacuum insulated temperature device that calibrates the resistance temperature characteristics of thermistors, so that it improves the temperature resolution and accuracy of skin cancer diagnosis. In this study, the operational methods of the calibration system were compared for improving further accuracy using the temperature calibration device and the oil tank calibration device. The results of the comparison indicated that the temperature calibration device is probably as accurate as the oil tank calibration device.</p>\",\"PeriodicalId\":50550,\"journal\":{\"name\":\"Electrical Engineering in Japan\",\"volume\":\"217 3\",\"pages\":\"\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Engineering in Japan\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/eej.23471\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering in Japan","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eej.23471","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Evaluation of a vacuum insulated temperature calibration device to calibrate thermistor characteristics for skin cancer diagnosis
Recent methods using thermistors as an early detection of skin cancer require the higher resolution of 5 mK. Previously, the authors developed a vacuum insulated temperature device that calibrates the resistance temperature characteristics of thermistors, so that it improves the temperature resolution and accuracy of skin cancer diagnosis. In this study, the operational methods of the calibration system were compared for improving further accuracy using the temperature calibration device and the oil tank calibration device. The results of the comparison indicated that the temperature calibration device is probably as accurate as the oil tank calibration device.
期刊介绍:
Electrical Engineering in Japan (EEJ) is an official journal of the Institute of Electrical Engineers of Japan (IEEJ). This authoritative journal is a translation of the Transactions of the Institute of Electrical Engineers of Japan. It publishes 16 issues a year on original research findings in Electrical Engineering with special focus on the science, technology and applications of electric power, such as power generation, transmission and conversion, electric railways (including magnetic levitation devices), motors, switching, power economics.