Kenzo Ichimura, Bettia E Celestin, Shadi P Bagherzadeh, Roham T Zamanian, Michael Salerno, Edda Spiekerkoetter, Francois Haddad
{"title":"肺动脉高压的三尖瓣环平面收缩期偏移--超越扇形平面。","authors":"Kenzo Ichimura, Bettia E Celestin, Shadi P Bagherzadeh, Roham T Zamanian, Michael Salerno, Edda Spiekerkoetter, Francois Haddad","doi":"10.1002/pul2.12416","DOIUrl":null,"url":null,"abstract":"<p><p>Tricuspid annular plane systolic excursion (TAPSE) is usually measured with M-mode using sector line, however, this may not align with the anatomical shortening of the right ventricular (RV). In this study, we compared the different methods to measure TAPSE using three different reference lines (sector line, anatomical line, and apico-annular line). We included 148 patients diagnosed with pulmonary arterial hypertension (PAH) who underwent TTE and right heart catheterization within 2 weeks of each other. TAPSE was measured by M-mode (sector, anatomical), 2D (sector, anatomical), or as tricuspid apico-annular displacement (TAAD). Agreement between measures was assessed using coefficient of variation (COV), Spearman's correlation, and Bland-Altman analysis. Receiver-operating characteristics and Kaplan-Meier analysis were used to explore associations with the combined outcome of death or lung transplantation at 5 years. There was a good concordance between anatomical and sector M-mode with a COV of 15.5 ± 1.6% and a bias of -0.6 ± 3.2 mm. In contrast, anatomical M-mode TAPSE and TAAD differed significantly with the mean difference of 3.3 ± 3.8 mm (COV 30.5 ± 6.1%; <i>p</i> < 0.0001). Among the different 2D methods, anatomical 2D agreed well with anatomical M-mode TAPSE (COV of 11.8 ± 2.0%; <i>r</i> = 0.89; <i>p</i> < 0.0001). Among the five methods, TADD had the strongest association with the combined endpoint of death or transplantation at 5 years (C-statistic 0.64, 95% confidence interval [CI] 0.57-0.71). We concluded that different measures of TAPSE are not interchangeable.</p>","PeriodicalId":20927,"journal":{"name":"Pulmonary Circulation","volume":"14 3","pages":"e12416"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11377954/pdf/","citationCount":"0","resultStr":"{\"title\":\"Tricuspid annular plane systolic excursion in pulmonary hypertension-Moving beyond the sector plane.\",\"authors\":\"Kenzo Ichimura, Bettia E Celestin, Shadi P Bagherzadeh, Roham T Zamanian, Michael Salerno, Edda Spiekerkoetter, Francois Haddad\",\"doi\":\"10.1002/pul2.12416\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tricuspid annular plane systolic excursion (TAPSE) is usually measured with M-mode using sector line, however, this may not align with the anatomical shortening of the right ventricular (RV). In this study, we compared the different methods to measure TAPSE using three different reference lines (sector line, anatomical line, and apico-annular line). We included 148 patients diagnosed with pulmonary arterial hypertension (PAH) who underwent TTE and right heart catheterization within 2 weeks of each other. TAPSE was measured by M-mode (sector, anatomical), 2D (sector, anatomical), or as tricuspid apico-annular displacement (TAAD). Agreement between measures was assessed using coefficient of variation (COV), Spearman's correlation, and Bland-Altman analysis. Receiver-operating characteristics and Kaplan-Meier analysis were used to explore associations with the combined outcome of death or lung transplantation at 5 years. There was a good concordance between anatomical and sector M-mode with a COV of 15.5 ± 1.6% and a bias of -0.6 ± 3.2 mm. In contrast, anatomical M-mode TAPSE and TAAD differed significantly with the mean difference of 3.3 ± 3.8 mm (COV 30.5 ± 6.1%; <i>p</i> < 0.0001). Among the different 2D methods, anatomical 2D agreed well with anatomical M-mode TAPSE (COV of 11.8 ± 2.0%; <i>r</i> = 0.89; <i>p</i> < 0.0001). Among the five methods, TADD had the strongest association with the combined endpoint of death or transplantation at 5 years (C-statistic 0.64, 95% confidence interval [CI] 0.57-0.71). We concluded that different measures of TAPSE are not interchangeable.</p>\",\"PeriodicalId\":20927,\"journal\":{\"name\":\"Pulmonary Circulation\",\"volume\":\"14 3\",\"pages\":\"e12416\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11377954/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pulmonary Circulation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/pul2.12416\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulmonary Circulation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/pul2.12416","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
三尖瓣瓣环平面收缩期偏移(TAPSE)通常使用扇形线通过 M 型测量,但这可能与右心室(RV)的解剖缩短不一致。在这项研究中,我们比较了使用三种不同参考线(扇形线、解剖线和心尖环线)测量 TAPSE 的不同方法。我们纳入了 148 名确诊为肺动脉高压(PAH)的患者,他们在两周内接受了 TTE 和右心导管检查。TAPSE通过M型(扇形、解剖型)、二维(扇形、解剖型)或三尖瓣心尖环线移位(TAAD)进行测量。采用变异系数 (COV)、斯皮尔曼相关性和布兰德-阿尔特曼分析评估测量值之间的一致性。采用受试者操作特征和卡普兰-梅尔分析来探讨与5年后死亡或肺移植的综合结果之间的关系。解剖M型和扇形M型的一致性很好,COV为15.5 ± 1.6%,偏差为-0.6 ± 3.2 mm。相比之下,解剖 M 型的 TAPSE 和 TAAD 有显著差异,平均差异为 3.3 ± 3.8 mm(COV 30.5 ± 6.1%;p r = 0.89;p r = 0.9)。
Tricuspid annular plane systolic excursion in pulmonary hypertension-Moving beyond the sector plane.
Tricuspid annular plane systolic excursion (TAPSE) is usually measured with M-mode using sector line, however, this may not align with the anatomical shortening of the right ventricular (RV). In this study, we compared the different methods to measure TAPSE using three different reference lines (sector line, anatomical line, and apico-annular line). We included 148 patients diagnosed with pulmonary arterial hypertension (PAH) who underwent TTE and right heart catheterization within 2 weeks of each other. TAPSE was measured by M-mode (sector, anatomical), 2D (sector, anatomical), or as tricuspid apico-annular displacement (TAAD). Agreement between measures was assessed using coefficient of variation (COV), Spearman's correlation, and Bland-Altman analysis. Receiver-operating characteristics and Kaplan-Meier analysis were used to explore associations with the combined outcome of death or lung transplantation at 5 years. There was a good concordance between anatomical and sector M-mode with a COV of 15.5 ± 1.6% and a bias of -0.6 ± 3.2 mm. In contrast, anatomical M-mode TAPSE and TAAD differed significantly with the mean difference of 3.3 ± 3.8 mm (COV 30.5 ± 6.1%; p < 0.0001). Among the different 2D methods, anatomical 2D agreed well with anatomical M-mode TAPSE (COV of 11.8 ± 2.0%; r = 0.89; p < 0.0001). Among the five methods, TADD had the strongest association with the combined endpoint of death or transplantation at 5 years (C-statistic 0.64, 95% confidence interval [CI] 0.57-0.71). We concluded that different measures of TAPSE are not interchangeable.
期刊介绍:
Pulmonary Circulation''s main goal is to encourage basic, translational, and clinical research by investigators, physician-scientists, and clinicans, in the hope of increasing survival rates for pulmonary hypertension and other pulmonary vascular diseases worldwide, and developing new therapeutic approaches for the diseases. Freely available online, Pulmonary Circulation allows diverse knowledge of research, techniques, and case studies to reach a wide readership of specialists in order to improve patient care and treatment outcomes.