Felipe Larios, Marcos R Gonzalez, Kim Ruiz-Arellanos, Maria L Inchaustegui, Juan Pretell-Mazzini, Juan Carlos G de la Blanca
{"title":"使用计算机辅助六爪外固定器进行复杂足踝重建--功能效果和并发症分析。","authors":"Felipe Larios, Marcos R Gonzalez, Kim Ruiz-Arellanos, Maria L Inchaustegui, Juan Pretell-Mazzini, Juan Carlos G de la Blanca","doi":"10.1016/j.fas.2024.08.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation.</p><p><strong>Methods: </strong>A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification.</p><p><strong>Results: </strong>A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %).</p><p><strong>Conclusions: </strong>Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.</p>","PeriodicalId":48743,"journal":{"name":"Foot and Ankle Surgery","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of computer-assisted hexapod external fixators for complex foot and ankle reconstructions - An analysis of functional outcomes and complications.\",\"authors\":\"Felipe Larios, Marcos R Gonzalez, Kim Ruiz-Arellanos, Maria L Inchaustegui, Juan Pretell-Mazzini, Juan Carlos G de la Blanca\",\"doi\":\"10.1016/j.fas.2024.08.010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation.</p><p><strong>Methods: </strong>A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification.</p><p><strong>Results: </strong>A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %).</p><p><strong>Conclusions: </strong>Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.</p>\",\"PeriodicalId\":48743,\"journal\":{\"name\":\"Foot and Ankle Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Foot and Ankle Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.fas.2024.08.010\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.fas.2024.08.010","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Use of computer-assisted hexapod external fixators for complex foot and ankle reconstructions - An analysis of functional outcomes and complications.
Introduction: Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation.
Methods: A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification.
Results: A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %).
Conclusions: Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.
期刊介绍:
Foot and Ankle Surgery is essential reading for everyone interested in the foot and ankle and its disorders. The approach is broad and includes all aspects of the subject from basic science to clinical management. Problems of both children and adults are included, as is trauma and chronic disease. Foot and Ankle Surgery is the official journal of European Foot and Ankle Society.
The aims of this journal are to promote the art and science of ankle and foot surgery, to publish peer-reviewed research articles, to provide regular reviews by acknowledged experts on common problems, and to provide a forum for discussion with letters to the Editors. Reviews of books are also published. Papers are invited for possible publication in Foot and Ankle Surgery on the understanding that the material has not been published elsewhere or accepted for publication in another journal and does not infringe prior copyright.