Yao Chen, Savannah M. Decker, Petr Bruza, David J. Gladstone, Lesley A. Jarvis, Brian W. Pogue, Kimberley S. Samkoe, Rongxiao Zhang
{"title":"利用切伦科夫成像生物形态特征验证乳腺放疗中可变形组织移位的患者定位","authors":"Yao Chen, Savannah M. Decker, Petr Bruza, David J. Gladstone, Lesley A. Jarvis, Brian W. Pogue, Kimberley S. Samkoe, Rongxiao Zhang","doi":"arxiv-2409.05680","DOIUrl":null,"url":null,"abstract":"Accurate patient positioning is critical for precise radiotherapy dose\ndelivery, as positioning errors can significantly affect treatment outcomes.\nThis study introduces a novel method for tracking loco-regional tissue\ndeformation through Cherenkov image analysis during fractionated breast cancer\nradiotherapy. The primary goal was to develop and test an algorithm for\nCherenkov-based regional position accuracy quantification, specifically for\nloco-regional deformations, which lack ideal quantification methods in\nradiotherapy. Blood vessel detection and segmentation were developed in\nCherenkov images using a tissue phantom with incremental movements, and later\napplied to images from fractionated whole breast radiotherapy in human patients\n(n=10). A combined rigid and non-rigid registration technique was used to\ndetect inter- and intra-fractional positioning variations. This approach\nquantified positioning variations in two parts: a global shift from rigid\nregistration and a two-dimensional variation map of loco-regional deformation\nfrom non-rigid registration. The methodology was validated using an\nanthropomorphic chest phantom experiment, where known treatment couch\ntranslations and respiratory motion were simulated to assess inter- and\nintra-fractional uncertainties, yielding an average accuracy of 0.83 mm for\ncouch translations up to 20 mm. Analysis of clinical Cherenkov data from ten\nbreast cancer patients showed an inter-fraction setup variation of 3.7 plus\nminus 2.4 mm relative to the first fraction and loco-regional deformations\n(95th percentile) of up to 3.3 plus minus 1.9 mm. This study presents a\nCherenkov-based approach to quantify global and local positioning variations,\ndemonstrating feasibility in addressing loco-regional deformations that\nconventional imaging techniques fail to capture.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cherenkov Imaged Bio-morphological Features Verify Patient Positioning with Deformable Tissue Translocation in Breast Radiotherapy\",\"authors\":\"Yao Chen, Savannah M. Decker, Petr Bruza, David J. Gladstone, Lesley A. Jarvis, Brian W. Pogue, Kimberley S. Samkoe, Rongxiao Zhang\",\"doi\":\"arxiv-2409.05680\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate patient positioning is critical for precise radiotherapy dose\\ndelivery, as positioning errors can significantly affect treatment outcomes.\\nThis study introduces a novel method for tracking loco-regional tissue\\ndeformation through Cherenkov image analysis during fractionated breast cancer\\nradiotherapy. The primary goal was to develop and test an algorithm for\\nCherenkov-based regional position accuracy quantification, specifically for\\nloco-regional deformations, which lack ideal quantification methods in\\nradiotherapy. Blood vessel detection and segmentation were developed in\\nCherenkov images using a tissue phantom with incremental movements, and later\\napplied to images from fractionated whole breast radiotherapy in human patients\\n(n=10). A combined rigid and non-rigid registration technique was used to\\ndetect inter- and intra-fractional positioning variations. This approach\\nquantified positioning variations in two parts: a global shift from rigid\\nregistration and a two-dimensional variation map of loco-regional deformation\\nfrom non-rigid registration. The methodology was validated using an\\nanthropomorphic chest phantom experiment, where known treatment couch\\ntranslations and respiratory motion were simulated to assess inter- and\\nintra-fractional uncertainties, yielding an average accuracy of 0.83 mm for\\ncouch translations up to 20 mm. Analysis of clinical Cherenkov data from ten\\nbreast cancer patients showed an inter-fraction setup variation of 3.7 plus\\nminus 2.4 mm relative to the first fraction and loco-regional deformations\\n(95th percentile) of up to 3.3 plus minus 1.9 mm. This study presents a\\nCherenkov-based approach to quantify global and local positioning variations,\\ndemonstrating feasibility in addressing loco-regional deformations that\\nconventional imaging techniques fail to capture.\",\"PeriodicalId\":501378,\"journal\":{\"name\":\"arXiv - PHYS - Medical Physics\",\"volume\":\"31 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - PHYS - Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2409.05680\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2409.05680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cherenkov Imaged Bio-morphological Features Verify Patient Positioning with Deformable Tissue Translocation in Breast Radiotherapy
Accurate patient positioning is critical for precise radiotherapy dose
delivery, as positioning errors can significantly affect treatment outcomes.
This study introduces a novel method for tracking loco-regional tissue
deformation through Cherenkov image analysis during fractionated breast cancer
radiotherapy. The primary goal was to develop and test an algorithm for
Cherenkov-based regional position accuracy quantification, specifically for
loco-regional deformations, which lack ideal quantification methods in
radiotherapy. Blood vessel detection and segmentation were developed in
Cherenkov images using a tissue phantom with incremental movements, and later
applied to images from fractionated whole breast radiotherapy in human patients
(n=10). A combined rigid and non-rigid registration technique was used to
detect inter- and intra-fractional positioning variations. This approach
quantified positioning variations in two parts: a global shift from rigid
registration and a two-dimensional variation map of loco-regional deformation
from non-rigid registration. The methodology was validated using an
anthropomorphic chest phantom experiment, where known treatment couch
translations and respiratory motion were simulated to assess inter- and
intra-fractional uncertainties, yielding an average accuracy of 0.83 mm for
couch translations up to 20 mm. Analysis of clinical Cherenkov data from ten
breast cancer patients showed an inter-fraction setup variation of 3.7 plus
minus 2.4 mm relative to the first fraction and loco-regional deformations
(95th percentile) of up to 3.3 plus minus 1.9 mm. This study presents a
Cherenkov-based approach to quantify global and local positioning variations,
demonstrating feasibility in addressing loco-regional deformations that
conventional imaging techniques fail to capture.