不断变化的气候条件下砖墙的湿热风险评估工具

IF 1.8 4区 工程技术 Q3 CONSTRUCTION & BUILDING TECHNOLOGY Journal of Building Physics Pub Date : 2024-08-12 DOI:10.1177/17442591241266484
Kaat Janssens, Isabeau Vandemeulebroucke, Valentina Marincioni, Nathan Van Den Bossche
{"title":"不断变化的气候条件下砖墙的湿热风险评估工具","authors":"Kaat Janssens, Isabeau Vandemeulebroucke, Valentina Marincioni, Nathan Van Den Bossche","doi":"10.1177/17442591241266484","DOIUrl":null,"url":null,"abstract":"Due to the heritage value of historical buildings, external facades can often not be modified. Therefore, in heritage buildings interior insulation is often considered when undergoing an energy renovation. However, interior retrofitting drastically changes the hygrothermal behaviour of a wall and can potentially cause moisture-related problems. Besides an interior retrofit, a changing climate might also trigger some of these damage mechanisms as parameters such as temperature and precipitation will change over time. Hygrothermal models can provide relevant insights into the risk of deterioration associated with these damage phenomena. However, these Heat, Air and Moisture (HAM) tools are commercially available but rarely used in the building industry to study deterioration risks. Translating research into practical tools and guidelines is a challenge across the whole field of building renovation. This paper aims to tackle that challenge, by means of creating a hygrothermal risk assessment tool based on 48,384 HAM-simulations for the climate of Brussels, Belgium. Seven different performance criteria are addressed and discussed: freeze-thaw damage, mould growth, wood rot, corrosion, moisture accumulation, salt efflorescence and bio-colonisation. Subsequent to a sensitivity analysis, the study further explains how these results can be translated into practice, providing building practitioners the most suitable insights and recommendations. The development of an interactive web tool to assess hygrothermal risks is demonstrated and its use and benefits are further elaborated.","PeriodicalId":50249,"journal":{"name":"Journal of Building Physics","volume":"59 1","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hygrothermal risk assessment tool for brick walls in a changing climate\",\"authors\":\"Kaat Janssens, Isabeau Vandemeulebroucke, Valentina Marincioni, Nathan Van Den Bossche\",\"doi\":\"10.1177/17442591241266484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to the heritage value of historical buildings, external facades can often not be modified. Therefore, in heritage buildings interior insulation is often considered when undergoing an energy renovation. However, interior retrofitting drastically changes the hygrothermal behaviour of a wall and can potentially cause moisture-related problems. Besides an interior retrofit, a changing climate might also trigger some of these damage mechanisms as parameters such as temperature and precipitation will change over time. Hygrothermal models can provide relevant insights into the risk of deterioration associated with these damage phenomena. However, these Heat, Air and Moisture (HAM) tools are commercially available but rarely used in the building industry to study deterioration risks. Translating research into practical tools and guidelines is a challenge across the whole field of building renovation. This paper aims to tackle that challenge, by means of creating a hygrothermal risk assessment tool based on 48,384 HAM-simulations for the climate of Brussels, Belgium. Seven different performance criteria are addressed and discussed: freeze-thaw damage, mould growth, wood rot, corrosion, moisture accumulation, salt efflorescence and bio-colonisation. Subsequent to a sensitivity analysis, the study further explains how these results can be translated into practice, providing building practitioners the most suitable insights and recommendations. The development of an interactive web tool to assess hygrothermal risks is demonstrated and its use and benefits are further elaborated.\",\"PeriodicalId\":50249,\"journal\":{\"name\":\"Journal of Building Physics\",\"volume\":\"59 1\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Building Physics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/17442591241266484\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Building Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17442591241266484","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

由于历史建筑具有文物价值,其外立面通常不能进行改造。因此,在对历史建筑进行能源改造时,通常会考虑内部隔热。然而,内部改造会极大地改变墙体的湿热性能,并可能引发与湿气相关的问题。除了室内改造之外,气候的变化也可能引发其中一些破坏机制,因为温度和降水等参数会随着时间的推移而发生变化。湿热模型可以提供与这些破坏现象相关的劣化风险的相关见解。然而,这些热量、空气和湿度(HAM)工具在市场上可以买到,却很少用于建筑行业的老化风险研究。将研究成果转化为实用工具和指南是整个建筑翻新领域面临的挑战。本文旨在应对这一挑战,以比利时布鲁塞尔的气候为基础,通过 48,384 次 HAM 模拟,创建湿热风险评估工具。本文讨论了七种不同的性能标准:冻融破坏、霉菌生长、木材腐烂、腐蚀、湿度累积、盐分渗出和生物菌落。在进行了敏感性分析之后,该研究进一步解释了如何将这些结果转化为实践,为建筑从业人员提供最合适的见解和建议。研究还展示了用于评估湿热风险的交互式网络工具的开发过程,并进一步阐述了该工具的用途和优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hygrothermal risk assessment tool for brick walls in a changing climate
Due to the heritage value of historical buildings, external facades can often not be modified. Therefore, in heritage buildings interior insulation is often considered when undergoing an energy renovation. However, interior retrofitting drastically changes the hygrothermal behaviour of a wall and can potentially cause moisture-related problems. Besides an interior retrofit, a changing climate might also trigger some of these damage mechanisms as parameters such as temperature and precipitation will change over time. Hygrothermal models can provide relevant insights into the risk of deterioration associated with these damage phenomena. However, these Heat, Air and Moisture (HAM) tools are commercially available but rarely used in the building industry to study deterioration risks. Translating research into practical tools and guidelines is a challenge across the whole field of building renovation. This paper aims to tackle that challenge, by means of creating a hygrothermal risk assessment tool based on 48,384 HAM-simulations for the climate of Brussels, Belgium. Seven different performance criteria are addressed and discussed: freeze-thaw damage, mould growth, wood rot, corrosion, moisture accumulation, salt efflorescence and bio-colonisation. Subsequent to a sensitivity analysis, the study further explains how these results can be translated into practice, providing building practitioners the most suitable insights and recommendations. The development of an interactive web tool to assess hygrothermal risks is demonstrated and its use and benefits are further elaborated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Building Physics
Journal of Building Physics 工程技术-结构与建筑技术
CiteScore
5.10
自引率
15.00%
发文量
10
审稿时长
5.3 months
期刊介绍: Journal of Building Physics (J. Bldg. Phys) is an international, peer-reviewed journal that publishes a high quality research and state of the art “integrated” papers to promote scientifically thorough advancement of all the areas of non-structural performance of a building and particularly in heat, air, moisture transfer.
期刊最新文献
Predictive heating load management and energy flexibility analysis in residential sector using an archetype gray-box modeling approach: Application to an experimental house in Québec. A review of complex window-glazing systems for building energy saving and daylight comfort: Glazing technologies and their building performance prediction Wind environment and pollutant dispersion around high-rise buildings with different void space structures Definition, estimation and decoupling of the overall uncertainty of the outdoor air temperature measurement surrounding a building envelope Hygrothermal risk assessment tool for brick walls in a changing climate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1