Philipp Bredol, Felix David, Nagesh S. Jagtap, Yannick S. Klaß, Georgy V. Astakhov, Artur Erbe, Eva M. Weig
{"title":"氦离子植入对 3C-SiC 纳米机械弦谐振器的影响","authors":"Philipp Bredol, Felix David, Nagesh S. Jagtap, Yannick S. Klaß, Georgy V. Astakhov, Artur Erbe, Eva M. Weig","doi":"10.1103/physrevapplied.22.034036","DOIUrl":null,"url":null,"abstract":"Hybrid quantum devices enable novel functionalities by combining the benefits of different subsystems. Particularly, point defects in nanomechanical resonators made of diamond or silicon carbide (SiC) have been proposed for precise magnetic field sensing and as versatile quantum transducers. However, the realization of a hybrid system may involve trade-offs in the performance of the constituent subsystems. In a spin-mechanical system, the mechanical properties of the resonator may suffer from the presence of engineered defects in the crystal lattice. This may severely restrict the performance of the resulting device and needs to be carefully explored. Here we focus on the impact of defects on high-<math display=\"inline\" overflow=\"scroll\" xmlns=\"http://www.w3.org/1998/Math/MathML\"><mi>Q</mi></math> nanomechanical string resonators made of prestressed <math display=\"inline\" overflow=\"scroll\" xmlns=\"http://www.w3.org/1998/Math/MathML\"><mn>3</mn><mi>C</mi></math>-SiC grown on Si(111). We use helium-ion implantation to create point defects and study their accumulated effect on the mechanical performance. Using Euler-Bernoulli beam theory, we present a method to determine Young’s modulus and the prestress of the strings. We find that Young’s modulus is not modified by implantation. Under implantation doses relevant for single-defect or defect-ensemble generation, both tensile stress and damping rate also remain unaltered. For a higher implantation dose, both exhibit a characteristic change.","PeriodicalId":20109,"journal":{"name":"Physical Review Applied","volume":"36 1","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of helium-ion implantation on 3C-SiC nanomechanical string resonators\",\"authors\":\"Philipp Bredol, Felix David, Nagesh S. Jagtap, Yannick S. Klaß, Georgy V. Astakhov, Artur Erbe, Eva M. Weig\",\"doi\":\"10.1103/physrevapplied.22.034036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hybrid quantum devices enable novel functionalities by combining the benefits of different subsystems. Particularly, point defects in nanomechanical resonators made of diamond or silicon carbide (SiC) have been proposed for precise magnetic field sensing and as versatile quantum transducers. However, the realization of a hybrid system may involve trade-offs in the performance of the constituent subsystems. In a spin-mechanical system, the mechanical properties of the resonator may suffer from the presence of engineered defects in the crystal lattice. This may severely restrict the performance of the resulting device and needs to be carefully explored. Here we focus on the impact of defects on high-<math display=\\\"inline\\\" overflow=\\\"scroll\\\" xmlns=\\\"http://www.w3.org/1998/Math/MathML\\\"><mi>Q</mi></math> nanomechanical string resonators made of prestressed <math display=\\\"inline\\\" overflow=\\\"scroll\\\" xmlns=\\\"http://www.w3.org/1998/Math/MathML\\\"><mn>3</mn><mi>C</mi></math>-SiC grown on Si(111). We use helium-ion implantation to create point defects and study their accumulated effect on the mechanical performance. Using Euler-Bernoulli beam theory, we present a method to determine Young’s modulus and the prestress of the strings. We find that Young’s modulus is not modified by implantation. Under implantation doses relevant for single-defect or defect-ensemble generation, both tensile stress and damping rate also remain unaltered. For a higher implantation dose, both exhibit a characteristic change.\",\"PeriodicalId\":20109,\"journal\":{\"name\":\"Physical Review Applied\",\"volume\":\"36 1\",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical Review Applied\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1103/physrevapplied.22.034036\",\"RegionNum\":2,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Review Applied","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1103/physrevapplied.22.034036","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
Effect of helium-ion implantation on 3C-SiC nanomechanical string resonators
Hybrid quantum devices enable novel functionalities by combining the benefits of different subsystems. Particularly, point defects in nanomechanical resonators made of diamond or silicon carbide (SiC) have been proposed for precise magnetic field sensing and as versatile quantum transducers. However, the realization of a hybrid system may involve trade-offs in the performance of the constituent subsystems. In a spin-mechanical system, the mechanical properties of the resonator may suffer from the presence of engineered defects in the crystal lattice. This may severely restrict the performance of the resulting device and needs to be carefully explored. Here we focus on the impact of defects on high- nanomechanical string resonators made of prestressed -SiC grown on Si(111). We use helium-ion implantation to create point defects and study their accumulated effect on the mechanical performance. Using Euler-Bernoulli beam theory, we present a method to determine Young’s modulus and the prestress of the strings. We find that Young’s modulus is not modified by implantation. Under implantation doses relevant for single-defect or defect-ensemble generation, both tensile stress and damping rate also remain unaltered. For a higher implantation dose, both exhibit a characteristic change.
期刊介绍:
Physical Review Applied (PRApplied) publishes high-quality papers that bridge the gap between engineering and physics, and between current and future technologies. PRApplied welcomes papers from both the engineering and physics communities, in academia and industry.
PRApplied focuses on topics including:
Biophysics, bioelectronics, and biomedical engineering,
Device physics,
Electronics,
Technology to harvest, store, and transmit energy, focusing on renewable energy technologies,
Geophysics and space science,
Industrial physics,
Magnetism and spintronics,
Metamaterials,
Microfluidics,
Nonlinear dynamics and pattern formation in natural or manufactured systems,
Nanoscience and nanotechnology,
Optics, optoelectronics, photonics, and photonic devices,
Quantum information processing, both algorithms and hardware,
Soft matter physics, including granular and complex fluids and active matter.