在临床相关的内皮化硅胶模型中,对支架牵引器牵引后的血管损伤进行体外评估。

IF 3.1 3区 医学 Q2 CLINICAL NEUROLOGY American Journal of Neuroradiology Pub Date : 2024-09-11 DOI:10.3174/ajnr.a8495
Isabelle Starr,Harrison Oen,Alyssa McCulloch,Sergey Frenklakh,Ryan Grandfield,Hana Choe,Kristen O'Halloran Cardinal
{"title":"在临床相关的内皮化硅胶模型中,对支架牵引器牵引后的血管损伤进行体外评估。","authors":"Isabelle Starr,Harrison Oen,Alyssa McCulloch,Sergey Frenklakh,Ryan Grandfield,Hana Choe,Kristen O'Halloran Cardinal","doi":"10.3174/ajnr.a8495","DOIUrl":null,"url":null,"abstract":"Mechanical thrombectomy devices have potential to injure the vessel during treatment of acute ischemic stroke. The goal of the current work was to tailor in vitro endothelialized silicone models for stent retriever assessment and to evaluate endothelial injury following treatment by various stent retriever designs and sizes. Clinically-relevant neurovascular geometries were first modeled out of silicone, then sterilized, coated with fibronectin, placed in bioreactors, seeded with human endothelial cells, and cultivated under flow. Several sizes of two different commercially available stent retrievers were then deployed in, and retracted through, vessels. Vessels were immediately harvested and stained. Endothelial injury, identified as denudation, was quantified using ImageJ. Results illustrated that endothelial injury ranged from 16-18% in wire/microcatheter-only treated vessels, 37-61% in 1-pass treatments, and 52-70% in 2-pass treatments. Overall this work showcases an in vitro approach for early stage assessment of the extent and location of vascular injury following stent retriever retraction.","PeriodicalId":7875,"journal":{"name":"American Journal of Neuroradiology","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro assessment of vascular injury following stent retriever retraction in clinically-relevant endothelialized silicone models.\",\"authors\":\"Isabelle Starr,Harrison Oen,Alyssa McCulloch,Sergey Frenklakh,Ryan Grandfield,Hana Choe,Kristen O'Halloran Cardinal\",\"doi\":\"10.3174/ajnr.a8495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mechanical thrombectomy devices have potential to injure the vessel during treatment of acute ischemic stroke. The goal of the current work was to tailor in vitro endothelialized silicone models for stent retriever assessment and to evaluate endothelial injury following treatment by various stent retriever designs and sizes. Clinically-relevant neurovascular geometries were first modeled out of silicone, then sterilized, coated with fibronectin, placed in bioreactors, seeded with human endothelial cells, and cultivated under flow. Several sizes of two different commercially available stent retrievers were then deployed in, and retracted through, vessels. Vessels were immediately harvested and stained. Endothelial injury, identified as denudation, was quantified using ImageJ. Results illustrated that endothelial injury ranged from 16-18% in wire/microcatheter-only treated vessels, 37-61% in 1-pass treatments, and 52-70% in 2-pass treatments. Overall this work showcases an in vitro approach for early stage assessment of the extent and location of vascular injury following stent retriever retraction.\",\"PeriodicalId\":7875,\"journal\":{\"name\":\"American Journal of Neuroradiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3174/ajnr.a8495\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3174/ajnr.a8495","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在治疗急性缺血性中风期间,机械血栓切除装置可能会损伤血管。当前工作的目标是定制体外内皮化硅胶模型,用于支架取栓器评估,并评估各种支架取栓器设计和尺寸治疗后的内皮损伤。首先用硅胶制作临床相关的神经血管几何模型,然后灭菌、涂上纤连蛋白、放入生物反应器、播种人内皮细胞并在流动状态下培养。然后,将两种不同尺寸的商用支架回收器放入血管中,并在血管中回缩。然后立即采集血管并进行染色。使用 ImageJ 对内皮损伤(即变性)进行量化。结果表明,在仅使用金属丝/微导管处理的血管中,内皮损伤率为 16-18%;在单通道处理中,内皮损伤率为 37-61%;在双通道处理中,内皮损伤率为 52-70%。总之,这项工作展示了一种体外方法,用于早期评估支架回缩器回缩后血管损伤的程度和位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vitro assessment of vascular injury following stent retriever retraction in clinically-relevant endothelialized silicone models.
Mechanical thrombectomy devices have potential to injure the vessel during treatment of acute ischemic stroke. The goal of the current work was to tailor in vitro endothelialized silicone models for stent retriever assessment and to evaluate endothelial injury following treatment by various stent retriever designs and sizes. Clinically-relevant neurovascular geometries were first modeled out of silicone, then sterilized, coated with fibronectin, placed in bioreactors, seeded with human endothelial cells, and cultivated under flow. Several sizes of two different commercially available stent retrievers were then deployed in, and retracted through, vessels. Vessels were immediately harvested and stained. Endothelial injury, identified as denudation, was quantified using ImageJ. Results illustrated that endothelial injury ranged from 16-18% in wire/microcatheter-only treated vessels, 37-61% in 1-pass treatments, and 52-70% in 2-pass treatments. Overall this work showcases an in vitro approach for early stage assessment of the extent and location of vascular injury following stent retriever retraction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.10
自引率
5.70%
发文量
506
审稿时长
2 months
期刊介绍: The mission of AJNR is to further knowledge in all aspects of neuroimaging, head and neck imaging, and spine imaging for neuroradiologists, radiologists, trainees, scientists, and associated professionals through print and/or electronic publication of quality peer-reviewed articles that lead to the highest standards in patient care, research, and education and to promote discussion of these and other issues through its electronic activities.
期刊最新文献
Artificial Intelligence-Generated Editorials in Radiology: Can Expert Editors Detect Them? The many faces of myxopapillary ependynomas. Vestibular schwannoma-related increased labyrinthine post-gadolinium 3D-FLAIR signal intensity and association with hearing impairment. CNS Embryonal Tumor with PLAGL Amplification, a New Tumor Type in Children and Adolescents: Insights from a Comprehensive MRI Analysis. DSA Quantitative Analysis and Predictive Modeling of Obliteration in Cerebral AVM following Stereotactic Radiosurgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1