{"title":"GPT-4 V 对日本全国临床工程师执业资格考试的反应分析","authors":"Kai Ishida, Naoya Arisaka, Kiyotaka Fujii","doi":"10.1007/s10916-024-02103-w","DOIUrl":null,"url":null,"abstract":"<p>Chat Generative Pretrained Transformer (ChatGPT; OpenAI) is a state-of-the-art large language model that can simulate human-like conversations based on user input. We evaluated the performance of GPT-4 V in the Japanese National Clinical Engineer Licensing Examination using 2,155 questions from 2012 to 2023. The average correct answer rate for all questions was 86.0%. In particular, clinical medicine, basic medicine, medical materials, biological properties, and mechanical engineering achieved a correct response rate of ≥ 90%. Conversely, medical device safety management, electrical and electronic engineering, and extracorporeal circulation obtained low correct answer rates ranging from 64.8% to 76.5%. The correct answer rates for questions that included figures/tables, required numerical calculation, figure/table ∩ calculation, and knowledge of Japanese Industrial Standards were 55.2%, 85.8%, 64.2% and 31.0%, respectively. The reason for the low correct answer rates is that ChatGPT lacked recognition of the images and knowledge of standards and laws. This study concludes that careful attention is required when using ChatGPT because several of its explanations lack the correct description.</p>","PeriodicalId":16338,"journal":{"name":"Journal of Medical Systems","volume":"12 1","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Responses of GPT-4 V to the Japanese National Clinical Engineer Licensing Examination\",\"authors\":\"Kai Ishida, Naoya Arisaka, Kiyotaka Fujii\",\"doi\":\"10.1007/s10916-024-02103-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Chat Generative Pretrained Transformer (ChatGPT; OpenAI) is a state-of-the-art large language model that can simulate human-like conversations based on user input. We evaluated the performance of GPT-4 V in the Japanese National Clinical Engineer Licensing Examination using 2,155 questions from 2012 to 2023. The average correct answer rate for all questions was 86.0%. In particular, clinical medicine, basic medicine, medical materials, biological properties, and mechanical engineering achieved a correct response rate of ≥ 90%. Conversely, medical device safety management, electrical and electronic engineering, and extracorporeal circulation obtained low correct answer rates ranging from 64.8% to 76.5%. The correct answer rates for questions that included figures/tables, required numerical calculation, figure/table ∩ calculation, and knowledge of Japanese Industrial Standards were 55.2%, 85.8%, 64.2% and 31.0%, respectively. The reason for the low correct answer rates is that ChatGPT lacked recognition of the images and knowledge of standards and laws. This study concludes that careful attention is required when using ChatGPT because several of its explanations lack the correct description.</p>\",\"PeriodicalId\":16338,\"journal\":{\"name\":\"Journal of Medical Systems\",\"volume\":\"12 1\",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Systems\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10916-024-02103-w\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Systems","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10916-024-02103-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

摘要

聊天生成预训练转换器(ChatGPT;OpenAI)是一种先进的大型语言模型,可根据用户输入模拟类似人类的对话。在日本全国临床工程师执业资格考试中,我们使用 2012 年至 2023 年的 2,155 道题目对 GPT-4 V 的性能进行了评估。所有问题的平均正确率为 86.0%。其中,临床医学、基础医学、医用材料、生物特性和机械工程的正确答题率≥90%。相反,医疗设备安全管理、电子电气工程和体外循环的正确答题率较低,从 64.8% 到 76.5%不等。包含数字/表格、需要数字计算、数字/表格∩计算和日本工业标准知识的题目的正确答对率分别为 55.2%、85.8%、64.2% 和 31.0%。答对率低的原因是 ChatGPT 缺乏对图像的识别以及标准和法律知识。本研究的结论是,在使用 ChatGPT 时需要小心谨慎,因为它的一些解释缺乏正确的描述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of Responses of GPT-4 V to the Japanese National Clinical Engineer Licensing Examination

Chat Generative Pretrained Transformer (ChatGPT; OpenAI) is a state-of-the-art large language model that can simulate human-like conversations based on user input. We evaluated the performance of GPT-4 V in the Japanese National Clinical Engineer Licensing Examination using 2,155 questions from 2012 to 2023. The average correct answer rate for all questions was 86.0%. In particular, clinical medicine, basic medicine, medical materials, biological properties, and mechanical engineering achieved a correct response rate of ≥ 90%. Conversely, medical device safety management, electrical and electronic engineering, and extracorporeal circulation obtained low correct answer rates ranging from 64.8% to 76.5%. The correct answer rates for questions that included figures/tables, required numerical calculation, figure/table ∩ calculation, and knowledge of Japanese Industrial Standards were 55.2%, 85.8%, 64.2% and 31.0%, respectively. The reason for the low correct answer rates is that ChatGPT lacked recognition of the images and knowledge of standards and laws. This study concludes that careful attention is required when using ChatGPT because several of its explanations lack the correct description.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Systems
Journal of Medical Systems 医学-卫生保健
CiteScore
11.60
自引率
1.90%
发文量
83
审稿时长
4.8 months
期刊介绍: Journal of Medical Systems provides a forum for the presentation and discussion of the increasingly extensive applications of new systems techniques and methods in hospital clinic and physician''s office administration; pathology radiology and pharmaceutical delivery systems; medical records storage and retrieval; and ancillary patient-support systems. The journal publishes informative articles essays and studies across the entire scale of medical systems from large hospital programs to novel small-scale medical services. Education is an integral part of this amalgamation of sciences and selected articles are published in this area. Since existing medical systems are constantly being modified to fit particular circumstances and to solve specific problems the journal includes a special section devoted to status reports on current installations.
期刊最新文献
Garbage In, Garbage Out? Negative Impact of Physiological Waveform Artifacts in a Hospital Clinical Data Warehouse. 21st Century Cures Act and Information Blocking: How Have Different Specialties Responded? Self-Supervised Learning for Near-Wild Cognitive Workload Estimation. Electronic Health Records Sharing Based on Consortium Blockchain. Large Language Models in Healthcare: An Urgent Call for Ongoing, Rigorous Validation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1