{"title":"STEP 电站的平顶等离子体运行空间","authors":"E. Tholerus, F.J. Casson, S.P. Marsden, T. Wilson, D. Brunetti, P. Fox, S.J. Freethy, T.C. Hender, S.S. Henderson, A. Hudoba, K.K. Kirov, F. Koechl, H. Meyer, S.I. Muldrew, C. Olde, B.S. Patel, C.M. Roach, S. Saarelma, G. Xia, the STEP team1","doi":"10.1088/1741-4326/ad6ea2","DOIUrl":null,"url":null,"abstract":"STEP is a spherical tokamak prototype power plant that is being designed to demonstrate net electric power. The design phase involves the exploitation of plasma models to optimise fusion performance subject to satisfying various physics and engineering constraints. A modelling workflow, including integrated core plasma modelling, MHD stability analysis, SOL and pedestal modelling, coil set and free boundary equilibrium solvers, and whole plant design, has been developed to specify the design parameters and to develop viable scenarios. The integrated core plasma model JETTO is used to develop individual flat-top operating points that satisfy imposed criteria for fusion power performance within operational constraints. Key plasma parameters such as normalised beta, Greenwald density fraction, auxiliary power and radiated power have been scanned to scope the operational space and to derive a collection of candidate non-inductive flat-top points. The assumed auxiliary heating and current drive is either from electron cyclotron (EC) systems only or a combination of EC and electron Bernstein waves. At present stages of transport modelling, there is a large uncertainty in overall confinement for relevant parameter regimes. For each of the two auxiliary heating and current drive systems scenarios, two candidate flat-top points have been developed based on different confinement assumptions, totalling to four operating points. A lower confinement assumption generally suggests operating points in high-density, high auxiliary power regimes, whereas higher confinement would allow access to a broader parameter regime in density and power while maintaining target fusion power performance.","PeriodicalId":19379,"journal":{"name":"Nuclear Fusion","volume":"21 1","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flat-top plasma operational space of the STEP power plant\",\"authors\":\"E. Tholerus, F.J. Casson, S.P. Marsden, T. Wilson, D. Brunetti, P. Fox, S.J. Freethy, T.C. Hender, S.S. Henderson, A. Hudoba, K.K. Kirov, F. Koechl, H. Meyer, S.I. Muldrew, C. Olde, B.S. Patel, C.M. Roach, S. Saarelma, G. Xia, the STEP team1\",\"doi\":\"10.1088/1741-4326/ad6ea2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"STEP is a spherical tokamak prototype power plant that is being designed to demonstrate net electric power. The design phase involves the exploitation of plasma models to optimise fusion performance subject to satisfying various physics and engineering constraints. A modelling workflow, including integrated core plasma modelling, MHD stability analysis, SOL and pedestal modelling, coil set and free boundary equilibrium solvers, and whole plant design, has been developed to specify the design parameters and to develop viable scenarios. The integrated core plasma model JETTO is used to develop individual flat-top operating points that satisfy imposed criteria for fusion power performance within operational constraints. Key plasma parameters such as normalised beta, Greenwald density fraction, auxiliary power and radiated power have been scanned to scope the operational space and to derive a collection of candidate non-inductive flat-top points. The assumed auxiliary heating and current drive is either from electron cyclotron (EC) systems only or a combination of EC and electron Bernstein waves. At present stages of transport modelling, there is a large uncertainty in overall confinement for relevant parameter regimes. For each of the two auxiliary heating and current drive systems scenarios, two candidate flat-top points have been developed based on different confinement assumptions, totalling to four operating points. A lower confinement assumption generally suggests operating points in high-density, high auxiliary power regimes, whereas higher confinement would allow access to a broader parameter regime in density and power while maintaining target fusion power performance.\",\"PeriodicalId\":19379,\"journal\":{\"name\":\"Nuclear Fusion\",\"volume\":\"21 1\",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Fusion\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1088/1741-4326/ad6ea2\",\"RegionNum\":1,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PHYSICS, FLUIDS & PLASMAS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Fusion","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1088/1741-4326/ad6ea2","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHYSICS, FLUIDS & PLASMAS","Score":null,"Total":0}
引用次数: 0

摘要

STEP 是一个球形托卡马克原型电站,其设计目的是演示净电力。设计阶段包括利用等离子体模型来优化聚变性能,同时满足各种物理和工程限制条件。已经开发了一个建模工作流程,包括综合核心等离子体建模、MHD 稳定性分析、SOL 和基座建模、线圈组和自由边界平衡求解器以及整个电站设计,以指定设计参数并开发可行的方案。综合核心等离子体模型 JETTO 用于开发单个平顶运行点,以满足在运行限制条件下聚变功率性能的既定标准。对关键等离子体参数(如归一化贝他值、格林沃尔德密度分数、辅助功率和辐射功率)进行了扫描,以确定运行空间的范围,并得出一系列候选非感应平顶点。假定的辅助加热和电流驱动要么仅来自电子回旋加速器(EC)系统,要么结合了电子回旋加速器和电子伯恩斯坦波。在目前的传输建模阶段,相关参数区的总体约束存在很大的不确定性。对于两种辅助加热和电流驱动系统方案中的每一种方案,都根据不同的约束假设开发了两个候选平顶点,总共有四个运行点。较低的约束假设一般建议在高密度、高辅助功率状态下的运行点,而较高的约束将允许在保持目标聚变功率性能的同时,进入密度和功率方面更宽泛的参数状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Flat-top plasma operational space of the STEP power plant
STEP is a spherical tokamak prototype power plant that is being designed to demonstrate net electric power. The design phase involves the exploitation of plasma models to optimise fusion performance subject to satisfying various physics and engineering constraints. A modelling workflow, including integrated core plasma modelling, MHD stability analysis, SOL and pedestal modelling, coil set and free boundary equilibrium solvers, and whole plant design, has been developed to specify the design parameters and to develop viable scenarios. The integrated core plasma model JETTO is used to develop individual flat-top operating points that satisfy imposed criteria for fusion power performance within operational constraints. Key plasma parameters such as normalised beta, Greenwald density fraction, auxiliary power and radiated power have been scanned to scope the operational space and to derive a collection of candidate non-inductive flat-top points. The assumed auxiliary heating and current drive is either from electron cyclotron (EC) systems only or a combination of EC and electron Bernstein waves. At present stages of transport modelling, there is a large uncertainty in overall confinement for relevant parameter regimes. For each of the two auxiliary heating and current drive systems scenarios, two candidate flat-top points have been developed based on different confinement assumptions, totalling to four operating points. A lower confinement assumption generally suggests operating points in high-density, high auxiliary power regimes, whereas higher confinement would allow access to a broader parameter regime in density and power while maintaining target fusion power performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nuclear Fusion
Nuclear Fusion 物理-物理:核物理
CiteScore
6.30
自引率
39.40%
发文量
411
审稿时长
2.6 months
期刊介绍: Nuclear Fusion publishes articles making significant advances to the field of controlled thermonuclear fusion. The journal scope includes: -the production, heating and confinement of high temperature plasmas; -the physical properties of such plasmas; -the experimental or theoretical methods of exploring or explaining them; -fusion reactor physics; -reactor concepts; and -fusion technologies. The journal has a dedicated Associate Editor for inertial confinement fusion.
期刊最新文献
Characterization of highly radiating nitrogen-seeded H-mode plasmas in unfavorable B T at ASDEX Upgrade Evolution of low-mode asymmetries introduced by x-ray P2 drive asymmetry during double shell implosions on the SG facility Tokamak edge-SOL turbulence in H-mode conditions simulated with a global, electromagnetic, transcollisional drift-fluid model The core–edge integrated neon-seeded scenario in deuterium–tritium at JET A self-organised partition of the high dimensional plasma parameter space for plasma disruption prediction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1