中子辐照基因突变的比较研究:溅射、反应堆和紧凑型中子源

May Sweet, Kenji Mishima, Masahide Harada, Keisuke Kurita, Hiroshi Iikura, Seiji Tasaki, Norio Kikuchi
{"title":"中子辐照基因突变的比较研究:溅射、反应堆和紧凑型中子源","authors":"May Sweet, Kenji Mishima, Masahide Harada, Keisuke Kurita, Hiroshi Iikura, Seiji Tasaki, Norio Kikuchi","doi":"arxiv-2408.10929","DOIUrl":null,"url":null,"abstract":"Neutron beam, being electrically neutral and highly penetrating, offers\nunique advantages for irradiation of biological species such as plants, seeds,\nand microorganisms. We comprehensively investigate the potential of neutron\nirradiation for inducing genetic mutations using simulations of J-PARC BL10,\nJRR-3 TNRF, and KUANS for spallation, reactor, and compact neutron sources. We\nanalyze neutron flux, energy deposition rates, and Linear Energy Transfer (LET)\ndistributions. KUANS demonstrated the highest dose rate of 17 Gy/h,\nsignificantly surpassing BL10, due to the large solid angle by the optimal\nsample placement. The findings highlight KUANS's suitability for efficient\ngenetic mutations and neutron breeding, particularly for inducing targeted\nmutations in biological samples. The LET range of KUANS is concentrated in\n20-70 keV/{\\mu}m, which is potentially ideal for inducing specific genetic\nmutations. The importance of choosing neutron sources based on LET requirements\nto maximize mutation induction efficiency is emphasized. This research shows\nthe potential of compact neutron sources like KUANS for effective biological\nirradiation and neutron breeding, offering a viable alternative to larger\nfacilities. The neutron filters used in BL10 and TNRF effectively excluded\nlow-energy neutrons with keeping the high LET component. The neutron capture\nreaction, 14N(n,p)14C, was found to be the main dose under thermal\nneutron-dominated conditions.","PeriodicalId":501040,"journal":{"name":"arXiv - PHYS - Biological Physics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Comparative Study of Neutron Irradiation for Genetic Mutations: Spallation, Reactor, and Compact Neutron Source\",\"authors\":\"May Sweet, Kenji Mishima, Masahide Harada, Keisuke Kurita, Hiroshi Iikura, Seiji Tasaki, Norio Kikuchi\",\"doi\":\"arxiv-2408.10929\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neutron beam, being electrically neutral and highly penetrating, offers\\nunique advantages for irradiation of biological species such as plants, seeds,\\nand microorganisms. We comprehensively investigate the potential of neutron\\nirradiation for inducing genetic mutations using simulations of J-PARC BL10,\\nJRR-3 TNRF, and KUANS for spallation, reactor, and compact neutron sources. We\\nanalyze neutron flux, energy deposition rates, and Linear Energy Transfer (LET)\\ndistributions. KUANS demonstrated the highest dose rate of 17 Gy/h,\\nsignificantly surpassing BL10, due to the large solid angle by the optimal\\nsample placement. The findings highlight KUANS's suitability for efficient\\ngenetic mutations and neutron breeding, particularly for inducing targeted\\nmutations in biological samples. The LET range of KUANS is concentrated in\\n20-70 keV/{\\\\mu}m, which is potentially ideal for inducing specific genetic\\nmutations. The importance of choosing neutron sources based on LET requirements\\nto maximize mutation induction efficiency is emphasized. This research shows\\nthe potential of compact neutron sources like KUANS for effective biological\\nirradiation and neutron breeding, offering a viable alternative to larger\\nfacilities. The neutron filters used in BL10 and TNRF effectively excluded\\nlow-energy neutrons with keeping the high LET component. The neutron capture\\nreaction, 14N(n,p)14C, was found to be the main dose under thermal\\nneutron-dominated conditions.\",\"PeriodicalId\":501040,\"journal\":{\"name\":\"arXiv - PHYS - Biological Physics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - PHYS - Biological Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2408.10929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Biological Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2408.10929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

中子束是电中性的,穿透力强,在辐照植物、种子和微生物等生物物种方面具有独特的优势。我们通过模拟 J-PARC BL10、JRR-3 TNRF 和 KUANS 的溅射、反应堆和紧凑型中子源,全面研究了中子辐照诱导基因突变的潜力。我们分析了中子通量、能量沉积率和线性能量传递(LET)分布。KUANS 的剂量率最高,达到 17 Gy/h,大大超过 BL10,这得益于优化的样品放置所产生的大固着角。这些研究结果突出表明,KUANS 适用于高效基因突变和中子培育,特别是在生物样本中诱导靶向突变。KUANS 的 LET 范围集中在 20-70 keV/{/mu}m,这可能是诱导特定基因突变的理想选择。强调了根据 LET 要求选择中子源以最大限度地提高突变诱导效率的重要性。这项研究表明,像 KUANS 这样的紧凑型中子源具有进行有效生物辐照和中子育种的潜力,为大型设施提供了可行的替代方案。BL10 和 TNRF 使用的中子滤波器在保留高 LET 成分的同时,有效地排除了低能中子。研究发现,在热中子主导条件下,中子俘获反应 14N(n,p)14C 是主要剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Comparative Study of Neutron Irradiation for Genetic Mutations: Spallation, Reactor, and Compact Neutron Source
Neutron beam, being electrically neutral and highly penetrating, offers unique advantages for irradiation of biological species such as plants, seeds, and microorganisms. We comprehensively investigate the potential of neutron irradiation for inducing genetic mutations using simulations of J-PARC BL10, JRR-3 TNRF, and KUANS for spallation, reactor, and compact neutron sources. We analyze neutron flux, energy deposition rates, and Linear Energy Transfer (LET) distributions. KUANS demonstrated the highest dose rate of 17 Gy/h, significantly surpassing BL10, due to the large solid angle by the optimal sample placement. The findings highlight KUANS's suitability for efficient genetic mutations and neutron breeding, particularly for inducing targeted mutations in biological samples. The LET range of KUANS is concentrated in 20-70 keV/{\mu}m, which is potentially ideal for inducing specific genetic mutations. The importance of choosing neutron sources based on LET requirements to maximize mutation induction efficiency is emphasized. This research shows the potential of compact neutron sources like KUANS for effective biological irradiation and neutron breeding, offering a viable alternative to larger facilities. The neutron filters used in BL10 and TNRF effectively excluded low-energy neutrons with keeping the high LET component. The neutron capture reaction, 14N(n,p)14C, was found to be the main dose under thermal neutron-dominated conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Error Thresholds in Presence of Epistatic Interactions Choice of Reference Surfaces to assess Plant Health through leaf scale temperature monitoring Physical Insights into Electromagnetic Efficiency of Wireless Implantable Bioelectronics Pseudo-RNA with parallel aligned single-strands and periodic base sequence as a new universality class Hydrodynamic hovering of swimming bacteria above surfaces
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1