基于干扰观测器的踝关节扭矩估算用于机器人康复

IF 1.8 4区 工程技术 Q3 ENGINEERING, MECHANICAL Journal of The Brazilian Society of Mechanical Sciences and Engineering Pub Date : 2024-08-14 DOI:10.1007/s40430-024-05132-1
Jonathan C. Jaimes, Alvaro D. Orjuela-Cañón, Adriano A. G. Siqueira
{"title":"基于干扰观测器的踝关节扭矩估算用于机器人康复","authors":"Jonathan C. Jaimes, Alvaro D. Orjuela-Cañón, Adriano A. G. Siqueira","doi":"10.1007/s40430-024-05132-1","DOIUrl":null,"url":null,"abstract":"<p>Designing safe and tailored strategies for robotic therapy requires the knowledge of patient joint torques, allowing control strategies to adjust the torque level provided by the robotic device according to the patient’s performance. Given the impracticability of measuring human joint torques directly, many works in the area have used estimation techniques that require complex calibration and signal processing or introduce uncertainty in their system modeling. This paper evaluates three disturbance observer techniques for estimating ankle joint torque as an alternative solution. Based on the generalized momentum and Kalman filter methodologies, the approaches were implemented on a robotic device for ankle rehabilitation. They were evaluated on six healthy voluntary users for sitting position movements. The techniques demonstrated effectiveness in estimating human joint torque across three distinct human–robot interaction modes, with performance evaluation through normalized root-mean-square error (NRMSE) metrics. Statistical analysis, including ANOVA, Kruskal–Wallis, and Dunn’s post hoc tests, was employed to assess approach performance and impact effects under different configuration settings. These analyses highlighted significant differences in performance among the techniques, enhancing the understanding of the estimation approaches and highlighting their potential integration into robotic rehabilitation settings.</p>","PeriodicalId":17252,"journal":{"name":"Journal of The Brazilian Society of Mechanical Sciences and Engineering","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ankle torque estimation based on disturbance observers for robotic rehabilitation\",\"authors\":\"Jonathan C. Jaimes, Alvaro D. Orjuela-Cañón, Adriano A. G. Siqueira\",\"doi\":\"10.1007/s40430-024-05132-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Designing safe and tailored strategies for robotic therapy requires the knowledge of patient joint torques, allowing control strategies to adjust the torque level provided by the robotic device according to the patient’s performance. Given the impracticability of measuring human joint torques directly, many works in the area have used estimation techniques that require complex calibration and signal processing or introduce uncertainty in their system modeling. This paper evaluates three disturbance observer techniques for estimating ankle joint torque as an alternative solution. Based on the generalized momentum and Kalman filter methodologies, the approaches were implemented on a robotic device for ankle rehabilitation. They were evaluated on six healthy voluntary users for sitting position movements. The techniques demonstrated effectiveness in estimating human joint torque across three distinct human–robot interaction modes, with performance evaluation through normalized root-mean-square error (NRMSE) metrics. Statistical analysis, including ANOVA, Kruskal–Wallis, and Dunn’s post hoc tests, was employed to assess approach performance and impact effects under different configuration settings. These analyses highlighted significant differences in performance among the techniques, enhancing the understanding of the estimation approaches and highlighting their potential integration into robotic rehabilitation settings.</p>\",\"PeriodicalId\":17252,\"journal\":{\"name\":\"Journal of The Brazilian Society of Mechanical Sciences and Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Brazilian Society of Mechanical Sciences and Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s40430-024-05132-1\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Brazilian Society of Mechanical Sciences and Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s40430-024-05132-1","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

要为机器人治疗设计安全且量身定制的策略,就必须了解患者的关节扭矩,从而制定控制策略,根据患者的表现调整机器人设备提供的扭矩水平。由于直接测量人体关节扭矩不切实际,该领域的许多研究都采用了需要复杂校准和信号处理的估算技术,或在系统建模中引入不确定性。本文评估了用于估算踝关节扭矩的三种干扰观测器技术,作为一种替代解决方案。基于广义动量和卡尔曼滤波方法,这些方法在用于踝关节康复的机器人设备上得以实现。对六名健康的自愿使用者的坐姿运动进行了评估。通过归一化均方根误差(NRMSE)指标进行性能评估,这些技术证明了在三种不同的人机交互模式下估算人体关节扭矩的有效性。统计分析包括方差分析、Kruskal-Wallis 和邓恩事后检验,用于评估不同配置设置下的接近性能和影响效果。这些分析凸显了不同技术在性能上的显著差异,加深了对估算方法的理解,并突出了将其整合到机器人康复设置中的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ankle torque estimation based on disturbance observers for robotic rehabilitation

Designing safe and tailored strategies for robotic therapy requires the knowledge of patient joint torques, allowing control strategies to adjust the torque level provided by the robotic device according to the patient’s performance. Given the impracticability of measuring human joint torques directly, many works in the area have used estimation techniques that require complex calibration and signal processing or introduce uncertainty in their system modeling. This paper evaluates three disturbance observer techniques for estimating ankle joint torque as an alternative solution. Based on the generalized momentum and Kalman filter methodologies, the approaches were implemented on a robotic device for ankle rehabilitation. They were evaluated on six healthy voluntary users for sitting position movements. The techniques demonstrated effectiveness in estimating human joint torque across three distinct human–robot interaction modes, with performance evaluation through normalized root-mean-square error (NRMSE) metrics. Statistical analysis, including ANOVA, Kruskal–Wallis, and Dunn’s post hoc tests, was employed to assess approach performance and impact effects under different configuration settings. These analyses highlighted significant differences in performance among the techniques, enhancing the understanding of the estimation approaches and highlighting their potential integration into robotic rehabilitation settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
13.60%
发文量
536
审稿时长
4.8 months
期刊介绍: The Journal of the Brazilian Society of Mechanical Sciences and Engineering publishes manuscripts on research, development and design related to science and technology in Mechanical Engineering. It is an interdisciplinary journal with interfaces to other branches of Engineering, as well as with Physics and Applied Mathematics. The Journal accepts manuscripts in four different formats: Full Length Articles, Review Articles, Book Reviews and Letters to the Editor. Interfaces with other branches of engineering, along with physics, applied mathematics and more Presents manuscripts on research, development and design related to science and technology in mechanical engineering.
期刊最新文献
Bio-inspired thin-walled energy absorber adapted from the xylem structure for enhanced vehicle safety Urban mobile robot routing using fast search random tree method (RRT) in obstacle environments Failure behavior study of repaired bismaleimide resin matrix composite laminates with considering repairing process Study on material removal and process optimization of composite material curved shell components robot grinding under flexible contact mode Investigations of injector deposits formation in a GDI flex-fuel engine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1