体外中子辐照大鼠模型中的通量-剂量转换系数

IF 2.6 3区 工程技术 Q1 NUCLEAR SCIENCE & TECHNOLOGY Nuclear Engineering and Technology Pub Date : 2024-09-04 DOI:10.1016/j.net.2024.08.056
Xiaomin Zhang, Xu Xu, Yong Yuan, Jing Ning, Dawei Li, Yunlong Ji
{"title":"体外中子辐照大鼠模型中的通量-剂量转换系数","authors":"Xiaomin Zhang, Xu Xu, Yong Yuan, Jing Ning, Dawei Li, Yunlong Ji","doi":"10.1016/j.net.2024.08.056","DOIUrl":null,"url":null,"abstract":"Fluence-to-dose conversion coefficients based on a developed rat model have been calculated for neutrons with energies <20 MeV using Monte Carlo N-particle code (MCNP), for the purpose of neutron radiation effect evaluation. The calculation was conducted respectively for 27 monodirectional monoenergetic neutron beams in the energy range 10 MeV to 20 MeV, under four different irradiation conditions: left lateral, right lateral, dorsal–ventral and ventral–dorsal. The neutron fluence-to-dose conversion coefficients for selected organs were presented in the study and can be used to determine the organ dose of the rats experimentally exposed to external neutron irradiation. The results in this work were compared with the published data based on a mouse model to investigate the effect of size and weight difference on neutron organ dose. The comparison results showed the fluence-to-dose conversion coefficients of the rat model have the similar energy dependency and sensitivity to irradiation conditions compared with that of the mouse model, and the weight and size difference in individuals could lead to different levels of neutron organ dose difference depending on neutron energy, irradiation conditions as well as the location of organs.","PeriodicalId":19272,"journal":{"name":"Nuclear Engineering and Technology","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fluence-to-dose conversion coefficients in a voxel rat model for external neutron irradiation\",\"authors\":\"Xiaomin Zhang, Xu Xu, Yong Yuan, Jing Ning, Dawei Li, Yunlong Ji\",\"doi\":\"10.1016/j.net.2024.08.056\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fluence-to-dose conversion coefficients based on a developed rat model have been calculated for neutrons with energies <20 MeV using Monte Carlo N-particle code (MCNP), for the purpose of neutron radiation effect evaluation. The calculation was conducted respectively for 27 monodirectional monoenergetic neutron beams in the energy range 10 MeV to 20 MeV, under four different irradiation conditions: left lateral, right lateral, dorsal–ventral and ventral–dorsal. The neutron fluence-to-dose conversion coefficients for selected organs were presented in the study and can be used to determine the organ dose of the rats experimentally exposed to external neutron irradiation. The results in this work were compared with the published data based on a mouse model to investigate the effect of size and weight difference on neutron organ dose. The comparison results showed the fluence-to-dose conversion coefficients of the rat model have the similar energy dependency and sensitivity to irradiation conditions compared with that of the mouse model, and the weight and size difference in individuals could lead to different levels of neutron organ dose difference depending on neutron energy, irradiation conditions as well as the location of organs.\",\"PeriodicalId\":19272,\"journal\":{\"name\":\"Nuclear Engineering and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-09-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Engineering and Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1016/j.net.2024.08.056\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.net.2024.08.056","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

为了评估中子辐射效应,我们使用蒙特卡洛 N 粒子代码(MCNP)计算了能量小于 20 MeV 的中子的通量-剂量转换系数,该系数基于开发的大鼠模型。在左外侧、右外侧、背-腹侧和腹-背侧四种不同的辐照条件下,分别对能量范围为 10 MeV 至 20 MeV 的 27 个单向单能中子束进行了计算。研究中提出了选定器官的中子辐照剂量转换系数,可用于确定大鼠在外部中子辐照实验中的器官剂量。这项工作的结果与已发表的基于小鼠模型的数据进行了比较,以研究体型和体重差异对中子器官剂量的影响。比较结果表明,与小鼠模型相比,大鼠模型的通量-剂量转换系数具有相似的能量依赖性和对辐照条件的敏感性,而个体的体重和体型差异会因中子能量、辐照条件和器官位置的不同而导致不同程度的中子器官剂量差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fluence-to-dose conversion coefficients in a voxel rat model for external neutron irradiation
Fluence-to-dose conversion coefficients based on a developed rat model have been calculated for neutrons with energies <20 MeV using Monte Carlo N-particle code (MCNP), for the purpose of neutron radiation effect evaluation. The calculation was conducted respectively for 27 monodirectional monoenergetic neutron beams in the energy range 10 MeV to 20 MeV, under four different irradiation conditions: left lateral, right lateral, dorsal–ventral and ventral–dorsal. The neutron fluence-to-dose conversion coefficients for selected organs were presented in the study and can be used to determine the organ dose of the rats experimentally exposed to external neutron irradiation. The results in this work were compared with the published data based on a mouse model to investigate the effect of size and weight difference on neutron organ dose. The comparison results showed the fluence-to-dose conversion coefficients of the rat model have the similar energy dependency and sensitivity to irradiation conditions compared with that of the mouse model, and the weight and size difference in individuals could lead to different levels of neutron organ dose difference depending on neutron energy, irradiation conditions as well as the location of organs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nuclear Engineering and Technology
Nuclear Engineering and Technology 工程技术-核科学技术
CiteScore
4.80
自引率
7.40%
发文量
431
审稿时长
3.5 months
期刊介绍: Nuclear Engineering and Technology (NET), an international journal of the Korean Nuclear Society (KNS), publishes peer-reviewed papers on original research, ideas and developments in all areas of the field of nuclear science and technology. NET bimonthly publishes original articles, reviews, and technical notes. The journal is listed in the Science Citation Index Expanded (SCIE) of Thomson Reuters. NET covers all fields for peaceful utilization of nuclear energy and radiation as follows: 1) Reactor Physics 2) Thermal Hydraulics 3) Nuclear Safety 4) Nuclear I&C 5) Nuclear Physics, Fusion, and Laser Technology 6) Nuclear Fuel Cycle and Radioactive Waste Management 7) Nuclear Fuel and Reactor Materials 8) Radiation Application 9) Radiation Protection 10) Nuclear Structural Analysis and Plant Management & Maintenance 11) Nuclear Policy, Economics, and Human Resource Development
期刊最新文献
An innovative and efficient implementation of matrix-free Newton krylov method for neutronics/thermal-hydraulics coupling simulation Numerical investigation of welding deformation diminution for double shell structure using the layered inherent strain The small modular molten salt reactor potential and opportunity in Saudi Arabia Kinetic simulation of uranium migration in granite fissure media of beishan, gansu, China: A case study based on the Laplace transform and inverse transform methods Fluence-to-dose conversion coefficients in a voxel rat model for external neutron irradiation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1