脑磁图的半解析三壳正向计算

IF 4.7 2区 医学 Q1 NEUROIMAGING NeuroImage Pub Date : 2024-09-16 DOI:10.1016/j.neuroimage.2024.120836
Dionysia Kaziki, Guido Nolte
{"title":"脑磁图的半解析三壳正向计算","authors":"Dionysia Kaziki,&nbsp;Guido Nolte","doi":"10.1016/j.neuroimage.2024.120836","DOIUrl":null,"url":null,"abstract":"<div><p>In previous studies, the magnetic lead field theorem in the quasi-static approximation was derived and used for the development of a method for the forward problem of MEG. It was applied and tested on a single-shell model of the human head and the question whether one shell is adequate enough for the calculation of the magnetic field is the main reason for this study. This forward method is based on the fundamental concept that one can calculate the lead field for MEG by decomposing it into two parts: the lead field of an arbitrary volume conductor that is already known and the gradient of basis functions that have to be harmonic, here derived from spherical harmonics. The problem then is reduced to evaluating the coefficients found in the basis functions. In this research we aim to improve the accuracy of the forward model, hence improving the localization accuracy in inverse methods by introducing a more detailed realistic head model. We here generalize the algorithm developed for a single-shell volume conductor to a three-shell volume conductor representing the brain, the skull and the skin with homogenous and isotropic conductivities in realistic ratios. The expansion to three shells could be tested as the three-shell algorithm is approaching the single-shell with high accuracy in special cases where three-shell solutions can also be calculated using a single-shell solution, especially for higher levels of expansion. The deviation in the calculation of the lead field is also evaluated when using three shells with realistic conductivities. The magnetic field turned out to differ to an important measurable extend in particular for deeper sources, making the three-shell algorithm substantially more accurate for these dipole locations.</p></div>","PeriodicalId":19299,"journal":{"name":"NeuroImage","volume":"299 ","pages":"Article 120836"},"PeriodicalIF":4.7000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1053811924003331/pdfft?md5=0a9251a7ae10c3d26551cba22d884b35&pid=1-s2.0-S1053811924003331-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Semi-analytic three-shell forward calculation for magnetoencephalography\",\"authors\":\"Dionysia Kaziki,&nbsp;Guido Nolte\",\"doi\":\"10.1016/j.neuroimage.2024.120836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In previous studies, the magnetic lead field theorem in the quasi-static approximation was derived and used for the development of a method for the forward problem of MEG. It was applied and tested on a single-shell model of the human head and the question whether one shell is adequate enough for the calculation of the magnetic field is the main reason for this study. This forward method is based on the fundamental concept that one can calculate the lead field for MEG by decomposing it into two parts: the lead field of an arbitrary volume conductor that is already known and the gradient of basis functions that have to be harmonic, here derived from spherical harmonics. The problem then is reduced to evaluating the coefficients found in the basis functions. In this research we aim to improve the accuracy of the forward model, hence improving the localization accuracy in inverse methods by introducing a more detailed realistic head model. We here generalize the algorithm developed for a single-shell volume conductor to a three-shell volume conductor representing the brain, the skull and the skin with homogenous and isotropic conductivities in realistic ratios. The expansion to three shells could be tested as the three-shell algorithm is approaching the single-shell with high accuracy in special cases where three-shell solutions can also be calculated using a single-shell solution, especially for higher levels of expansion. The deviation in the calculation of the lead field is also evaluated when using three shells with realistic conductivities. The magnetic field turned out to differ to an important measurable extend in particular for deeper sources, making the three-shell algorithm substantially more accurate for these dipole locations.</p></div>\",\"PeriodicalId\":19299,\"journal\":{\"name\":\"NeuroImage\",\"volume\":\"299 \",\"pages\":\"Article 120836\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1053811924003331/pdfft?md5=0a9251a7ae10c3d26551cba22d884b35&pid=1-s2.0-S1053811924003331-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NeuroImage\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1053811924003331\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NeuroImage","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1053811924003331","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

摘要

在以前的研究中,推导出准静态近似的磁导场定理,并将其用于 MEG 正向问题方法的开发。该方法在单壳人体头部模型上进行了应用和测试,而单壳是否足以计算磁场是本研究的主要原因。这种前瞻性方法基于一个基本概念,即可以通过将 MEG 的导磁场分解为两部分来计算:已知的任意体积导体的导磁场和必须是谐波的基函数梯度,这里的基函数是由球面谐波导出的。然后,问题就简化为评估基函数中的系数。在这项研究中,我们的目标是提高前向模型的精度,从而通过引入更详细的现实头部模型,提高逆向方法的定位精度。在此,我们将针对单壳体积导体开发的算法推广到代表大脑、头骨和皮肤的三壳体积导体,三壳体积导体具有同质和各向同性的传导率,且比例逼真。由于三壳算法在特殊情况下接近单壳算法时具有很高的精确度,因此可以对扩展到三壳进行测试,三壳解法也可以使用单壳解法进行计算,特别是对于较高的扩展水平。在使用具有实际电导率的三壳时,还对铅场计算的偏差进行了评估。结果表明,磁场的偏差达到了可测量的重要程度,特别是对于较深的磁源,使得三壳算法对于这些偶极位置的计算精度大大提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Semi-analytic three-shell forward calculation for magnetoencephalography

In previous studies, the magnetic lead field theorem in the quasi-static approximation was derived and used for the development of a method for the forward problem of MEG. It was applied and tested on a single-shell model of the human head and the question whether one shell is adequate enough for the calculation of the magnetic field is the main reason for this study. This forward method is based on the fundamental concept that one can calculate the lead field for MEG by decomposing it into two parts: the lead field of an arbitrary volume conductor that is already known and the gradient of basis functions that have to be harmonic, here derived from spherical harmonics. The problem then is reduced to evaluating the coefficients found in the basis functions. In this research we aim to improve the accuracy of the forward model, hence improving the localization accuracy in inverse methods by introducing a more detailed realistic head model. We here generalize the algorithm developed for a single-shell volume conductor to a three-shell volume conductor representing the brain, the skull and the skin with homogenous and isotropic conductivities in realistic ratios. The expansion to three shells could be tested as the three-shell algorithm is approaching the single-shell with high accuracy in special cases where three-shell solutions can also be calculated using a single-shell solution, especially for higher levels of expansion. The deviation in the calculation of the lead field is also evaluated when using three shells with realistic conductivities. The magnetic field turned out to differ to an important measurable extend in particular for deeper sources, making the three-shell algorithm substantially more accurate for these dipole locations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
NeuroImage
NeuroImage 医学-核医学
CiteScore
11.30
自引率
10.50%
发文量
809
审稿时长
63 days
期刊介绍: NeuroImage, a Journal of Brain Function provides a vehicle for communicating important advances in acquiring, analyzing, and modelling neuroimaging data and in applying these techniques to the study of structure-function and brain-behavior relationships. Though the emphasis is on the macroscopic level of human brain organization, meso-and microscopic neuroimaging across all species will be considered if informative for understanding the aforementioned relationships.
期刊最新文献
Differentiating atypical parkinsonian syndromes with hyperbolic few-shot contrastive learning Exploring the relationship between hallucination proneness and brain morphology Biological mechanism of sex differences in mental rotation: Evidence from multimodal MRI, transcriptomic and receptor/transporter data. Different oscillatory mechanisms of dementia-related diseases with cognitive impairment in closed-eye state. Generative Modeling of the Circle of Willis Using 3D-StyleGAN.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1