利用中尺度计算模型了解矿化和结构对肌腱-骨骼插入机械性能的影响

IF 3.3 2区 医学 Q2 ENGINEERING, BIOMEDICAL Journal of the Mechanical Behavior of Biomedical Materials Pub Date : 2024-09-10 DOI:10.1016/j.jmbbm.2024.106735
{"title":"利用中尺度计算模型了解矿化和结构对肌腱-骨骼插入机械性能的影响","authors":"","doi":"10.1016/j.jmbbm.2024.106735","DOIUrl":null,"url":null,"abstract":"<div><p>Tendon-bone fibrocartilaginous insertion, or enthesis, is a specialized interfacial region that connects tendon and bone, effectively transferring forces while minimizing stress concentrations. Previous studies have shown that insertion features gradient mineralization and branching fiber structure, which are believed to play critical roles in its excellent function. However, the specific structure-function relationship, particularly the effects of mineralization and structure at the mesoscale fiber level on the properties and function of insertion, remains poorly understood. In this study, we develop mesoscale computational models of the distinct fiber organization at tendon-bone insertions, capturing the branching network from tendon to interface fibers and the different mineralization scales. We specifically analyze three key descriptors: the mineralization scale of interface fibers, the mean, and relative standard deviation of the local branching angles of interface fibers. Tensile test simulations on insertion models with varying mineralization scales of interface fibers and structures are performed to mimic the primary loading condition applied to the insertion. We measure and analyze five representative mechanical properties: Young's modulus, strength, toughness, resilience, and failure strain. Our results reveal that mechanical properties are significantly influenced by the three key descriptors, with tradeoffs observed between mutually exclusive properties. For instance, strength and resilience plateau beyond a certain mineralization scale, while failure strain and Young's modulus exhibit monotonic decreasing and increasing trends, respectively. Consequently, there exists an optimal mineralization scale for toughness due to these tradeoffs. By analyzing the mesoscale deformation and failure mechanisms from simulation trajectories, we identify three fracture regimes closely related to the trends in mechanical properties, supporting the observed tradeoffs. Additionally, we examine in detail the effects of the mean and relative standard deviation of local branching angles on mechanical properties and deformation mechanisms. Overall, our study enhances the fundamental understanding of the composition-structure-function relationships at the tendon-bone insertion, complementing recent experimental studies. The mechanical insights from our work have the potential to guide the future biomimetic design of fibrillar adhesives and interfaces for joining soft and hard materials.</p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Understanding the effects of mineralization and structure on the mechanical properties of tendon-bone insertion using mesoscale computational modeling\",\"authors\":\"\",\"doi\":\"10.1016/j.jmbbm.2024.106735\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Tendon-bone fibrocartilaginous insertion, or enthesis, is a specialized interfacial region that connects tendon and bone, effectively transferring forces while minimizing stress concentrations. Previous studies have shown that insertion features gradient mineralization and branching fiber structure, which are believed to play critical roles in its excellent function. However, the specific structure-function relationship, particularly the effects of mineralization and structure at the mesoscale fiber level on the properties and function of insertion, remains poorly understood. In this study, we develop mesoscale computational models of the distinct fiber organization at tendon-bone insertions, capturing the branching network from tendon to interface fibers and the different mineralization scales. We specifically analyze three key descriptors: the mineralization scale of interface fibers, the mean, and relative standard deviation of the local branching angles of interface fibers. Tensile test simulations on insertion models with varying mineralization scales of interface fibers and structures are performed to mimic the primary loading condition applied to the insertion. We measure and analyze five representative mechanical properties: Young's modulus, strength, toughness, resilience, and failure strain. Our results reveal that mechanical properties are significantly influenced by the three key descriptors, with tradeoffs observed between mutually exclusive properties. For instance, strength and resilience plateau beyond a certain mineralization scale, while failure strain and Young's modulus exhibit monotonic decreasing and increasing trends, respectively. Consequently, there exists an optimal mineralization scale for toughness due to these tradeoffs. By analyzing the mesoscale deformation and failure mechanisms from simulation trajectories, we identify three fracture regimes closely related to the trends in mechanical properties, supporting the observed tradeoffs. Additionally, we examine in detail the effects of the mean and relative standard deviation of local branching angles on mechanical properties and deformation mechanisms. Overall, our study enhances the fundamental understanding of the composition-structure-function relationships at the tendon-bone insertion, complementing recent experimental studies. The mechanical insights from our work have the potential to guide the future biomimetic design of fibrillar adhesives and interfaces for joining soft and hard materials.</p></div>\",\"PeriodicalId\":380,\"journal\":{\"name\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1751616124003679\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124003679","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

肌腱-骨骼纤维软骨插入部(或称插入部)是连接肌腱和骨骼的特殊界面区域,可有效传递力量,同时最大限度地减少应力集中。以往的研究表明,插入部具有梯度矿化和分支纤维结构,这被认为是其发挥卓越功能的关键因素。然而,具体的结构-功能关系,尤其是中尺度纤维水平的矿化和结构对插入物特性和功能的影响,仍然知之甚少。在本研究中,我们开发了肌腱骨插入处不同纤维组织的中尺度计算模型,捕捉了从肌腱到界面纤维的分支网络以及不同的矿化尺度。我们特别分析了三个关键描述指标:界面纤维的矿化尺度、界面纤维局部分支角的平均值和相对标准偏差。我们对界面纤维和结构的矿化尺度不同的插入模型进行了拉伸试验模拟,以模拟施加到插入件上的主要加载条件。我们测量并分析了五种具有代表性的机械性能:杨氏模量、强度、韧性、回弹性和破坏应变。我们的研究结果表明,机械性能受三个关键描述因子的影响很大,同时还观察到相互排斥的性能之间存在折衷。例如,强度和回弹性在超过一定的矿化度后趋于稳定,而破坏应变和杨氏模量则分别呈现单调递减和递增的趋势。因此,由于这些权衡因素,韧性存在一个最佳矿化尺度。通过分析模拟轨迹的中尺度变形和破坏机制,我们确定了与力学性能趋势密切相关的三种断裂机制,从而支持了所观察到的权衡。此外,我们还详细研究了局部分支角的平均值和相对标准偏差对力学性能和变形机制的影响。总之,我们的研究增强了对肌腱骨插入处成分-结构-功能关系的基本认识,补充了近期的实验研究。从我们的研究中获得的力学见解有可能指导未来用于连接软硬材料的纤维粘合剂和界面的仿生设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Understanding the effects of mineralization and structure on the mechanical properties of tendon-bone insertion using mesoscale computational modeling

Tendon-bone fibrocartilaginous insertion, or enthesis, is a specialized interfacial region that connects tendon and bone, effectively transferring forces while minimizing stress concentrations. Previous studies have shown that insertion features gradient mineralization and branching fiber structure, which are believed to play critical roles in its excellent function. However, the specific structure-function relationship, particularly the effects of mineralization and structure at the mesoscale fiber level on the properties and function of insertion, remains poorly understood. In this study, we develop mesoscale computational models of the distinct fiber organization at tendon-bone insertions, capturing the branching network from tendon to interface fibers and the different mineralization scales. We specifically analyze three key descriptors: the mineralization scale of interface fibers, the mean, and relative standard deviation of the local branching angles of interface fibers. Tensile test simulations on insertion models with varying mineralization scales of interface fibers and structures are performed to mimic the primary loading condition applied to the insertion. We measure and analyze five representative mechanical properties: Young's modulus, strength, toughness, resilience, and failure strain. Our results reveal that mechanical properties are significantly influenced by the three key descriptors, with tradeoffs observed between mutually exclusive properties. For instance, strength and resilience plateau beyond a certain mineralization scale, while failure strain and Young's modulus exhibit monotonic decreasing and increasing trends, respectively. Consequently, there exists an optimal mineralization scale for toughness due to these tradeoffs. By analyzing the mesoscale deformation and failure mechanisms from simulation trajectories, we identify three fracture regimes closely related to the trends in mechanical properties, supporting the observed tradeoffs. Additionally, we examine in detail the effects of the mean and relative standard deviation of local branching angles on mechanical properties and deformation mechanisms. Overall, our study enhances the fundamental understanding of the composition-structure-function relationships at the tendon-bone insertion, complementing recent experimental studies. The mechanical insights from our work have the potential to guide the future biomimetic design of fibrillar adhesives and interfaces for joining soft and hard materials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
期刊最新文献
One-step synthesis of a piezoelectric hybrid BNNT/BaTiO3 composite and its application in bone tissue engineering Validation of finite-element-simulated orthodontic forces produced by thermoplastic aligners: Effect of aligner geometry and creep The influence of lumbar vertebra and cage related factors on cage-endplate contact after lumbar interbody fusion: An in-vitro experimental study A benchmark of muscle models to length changes great and small Designs and mechanical responses of 3D-printed Ti6Al4V porous structures based on triply periodic minimal surfaces with different iso-values
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1