{"title":"利用应激动态 CT 心肌灌注成像获得绝对心肌血流的测试再现性","authors":"Daisuke Hasegawa , Satoshi Nakamura , Masafumi Takafuji , Hajime Sakuma , Kakuya Kitagawa","doi":"10.1016/j.ijcha.2024.101510","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Coronary artery disease (CAD) and coronary microvascular disease (CMD) are significant contributors to angina pectoris, necessitating reliable diagnostic techniques for effective management. While positron emission tomography has been the non-invasive gold standard for myocardial blood flow (MBF) quantification, stress dynamic CT myocardial perfusion imaging (CTMPI) has emerged as a promising alternative. This study aimed to evaluate the test–retest reproducibility of MBF measurements obtained using dynamic CTMPI.</p></div><div><h3>Methods</h3><p>The study retrospectively analyzed MBF values from two dynamic CTMPI examinations conducted in the same patient cohort (n = 30) to examine the consistency of MBF quantification and the ability to visually detect and grade abnormal perfusion suggesting ischemia between the tests. Global and remote MBF were defined as the mean MBF and the maximum MBF of all segments, respectively.</p></div><div><h3>Results</h3><p>MBF quantification revealed strong linear correlations between the tests (r = 0.89 for global MBF, r = 0.88 for remote MBF, and r = 0.82 for all segments), and intraclass correlation coefficients reflected high agreement between the tests (0.94 for global MBF, 0.93 for remote MBF, and 0.90 for all segments). Bland-Altman plots indicated a negligible mean difference with acceptable limits of agreements between the tests for global MBF, remote MBF, and all segments. Visual assessment of the CTMPI maps for abnormal perfusion suggesting ischemia yielded a good inter-test agreement with a weighted kappa value of 0.80.</p></div><div><h3>Conclusion</h3><p>Dynamic CTMPI can consistently reproduce absolute MBF values and reliably detect myocardial perfusion abnormalities, potentially making it a robust diagnostic tool for evaluating the presence and severity of CAD and CMD.</p></div>","PeriodicalId":38026,"journal":{"name":"IJC Heart and Vasculature","volume":"55 ","pages":"Article 101510"},"PeriodicalIF":2.5000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352906724001763/pdfft?md5=e354d195fcc2d7c17056d0fe458e741c&pid=1-s2.0-S2352906724001763-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Test-retest reproducibility of absolute myocardial blood flow obtained using stress dynamic CT myocardial perfusion imaging\",\"authors\":\"Daisuke Hasegawa , Satoshi Nakamura , Masafumi Takafuji , Hajime Sakuma , Kakuya Kitagawa\",\"doi\":\"10.1016/j.ijcha.2024.101510\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Coronary artery disease (CAD) and coronary microvascular disease (CMD) are significant contributors to angina pectoris, necessitating reliable diagnostic techniques for effective management. While positron emission tomography has been the non-invasive gold standard for myocardial blood flow (MBF) quantification, stress dynamic CT myocardial perfusion imaging (CTMPI) has emerged as a promising alternative. This study aimed to evaluate the test–retest reproducibility of MBF measurements obtained using dynamic CTMPI.</p></div><div><h3>Methods</h3><p>The study retrospectively analyzed MBF values from two dynamic CTMPI examinations conducted in the same patient cohort (n = 30) to examine the consistency of MBF quantification and the ability to visually detect and grade abnormal perfusion suggesting ischemia between the tests. Global and remote MBF were defined as the mean MBF and the maximum MBF of all segments, respectively.</p></div><div><h3>Results</h3><p>MBF quantification revealed strong linear correlations between the tests (r = 0.89 for global MBF, r = 0.88 for remote MBF, and r = 0.82 for all segments), and intraclass correlation coefficients reflected high agreement between the tests (0.94 for global MBF, 0.93 for remote MBF, and 0.90 for all segments). Bland-Altman plots indicated a negligible mean difference with acceptable limits of agreements between the tests for global MBF, remote MBF, and all segments. Visual assessment of the CTMPI maps for abnormal perfusion suggesting ischemia yielded a good inter-test agreement with a weighted kappa value of 0.80.</p></div><div><h3>Conclusion</h3><p>Dynamic CTMPI can consistently reproduce absolute MBF values and reliably detect myocardial perfusion abnormalities, potentially making it a robust diagnostic tool for evaluating the presence and severity of CAD and CMD.</p></div>\",\"PeriodicalId\":38026,\"journal\":{\"name\":\"IJC Heart and Vasculature\",\"volume\":\"55 \",\"pages\":\"Article 101510\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2352906724001763/pdfft?md5=e354d195fcc2d7c17056d0fe458e741c&pid=1-s2.0-S2352906724001763-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IJC Heart and Vasculature\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352906724001763\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJC Heart and Vasculature","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352906724001763","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Test-retest reproducibility of absolute myocardial blood flow obtained using stress dynamic CT myocardial perfusion imaging
Background
Coronary artery disease (CAD) and coronary microvascular disease (CMD) are significant contributors to angina pectoris, necessitating reliable diagnostic techniques for effective management. While positron emission tomography has been the non-invasive gold standard for myocardial blood flow (MBF) quantification, stress dynamic CT myocardial perfusion imaging (CTMPI) has emerged as a promising alternative. This study aimed to evaluate the test–retest reproducibility of MBF measurements obtained using dynamic CTMPI.
Methods
The study retrospectively analyzed MBF values from two dynamic CTMPI examinations conducted in the same patient cohort (n = 30) to examine the consistency of MBF quantification and the ability to visually detect and grade abnormal perfusion suggesting ischemia between the tests. Global and remote MBF were defined as the mean MBF and the maximum MBF of all segments, respectively.
Results
MBF quantification revealed strong linear correlations between the tests (r = 0.89 for global MBF, r = 0.88 for remote MBF, and r = 0.82 for all segments), and intraclass correlation coefficients reflected high agreement between the tests (0.94 for global MBF, 0.93 for remote MBF, and 0.90 for all segments). Bland-Altman plots indicated a negligible mean difference with acceptable limits of agreements between the tests for global MBF, remote MBF, and all segments. Visual assessment of the CTMPI maps for abnormal perfusion suggesting ischemia yielded a good inter-test agreement with a weighted kappa value of 0.80.
Conclusion
Dynamic CTMPI can consistently reproduce absolute MBF values and reliably detect myocardial perfusion abnormalities, potentially making it a robust diagnostic tool for evaluating the presence and severity of CAD and CMD.
期刊介绍:
IJC Heart & Vasculature is an online-only, open-access journal dedicated to publishing original articles and reviews (also Editorials and Letters to the Editor) which report on structural and functional cardiovascular pathology, with an emphasis on imaging and disease pathophysiology. Articles must be authentic, educational, clinically relevant, and original in their content and scientific approach. IJC Heart & Vasculature requires the highest standards of scientific integrity in order to promote reliable, reproducible and verifiable research findings. All authors are advised to consult the Principles of Ethical Publishing in the International Journal of Cardiology before submitting a manuscript. Submission of a manuscript to this journal gives the publisher the right to publish that paper if it is accepted. Manuscripts may be edited to improve clarity and expression.