{"title":"混合纤维钢纤维加固混凝土梁中的纤维取向和取向系数:重要综述","authors":"Filippo Medeghini, Giuseppe Tiberti, Jajnabalkya Guhathakurta, Sven Simon, Giovanni A. Plizzari, Peter Mark","doi":"10.1002/suco.202400461","DOIUrl":null,"url":null,"abstract":"Fiber orientation is of paramount importance for the design of fiber‐reinforced concrete (FRC) structural elements, because it markedly influences the postcracking properties of such material. For this reason, structural codes introduce orientation factors which aim to correlate the real mechanical properties of the structural element with the ones determined from standard beams. Although the need of considering fiber orientation in design codes is commonly accepted, the orientation factors are still based on a limited number of research studies, raising the need to better determine fiber orientation to improve the current standards and support the design process of FRC elements. In this research, a steel fiber‐reinforced concrete (SFRC) with a hybrid system of macro and microfibers is steered into a broad range of fiber orientations and cast into standard beams. Besides measuring the mechanical performance of these SFRC beams, three different methods for assessing fiber orientation are employed, namely electromagnetic induction, image analysis, and micro‐computed tomography. The comparison between the outcomes of the different methods provides detailed information about the accuracy and suitability of each method, considering the corresponding domain of applicability at structural level. Finally, a critical review of the most common 2D and 3D orientation parameters found in literature is performed, and the equations are adapted to account for the hybrid system of fibers.","PeriodicalId":21988,"journal":{"name":"Structural Concrete","volume":"39 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review\",\"authors\":\"Filippo Medeghini, Giuseppe Tiberti, Jajnabalkya Guhathakurta, Sven Simon, Giovanni A. Plizzari, Peter Mark\",\"doi\":\"10.1002/suco.202400461\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fiber orientation is of paramount importance for the design of fiber‐reinforced concrete (FRC) structural elements, because it markedly influences the postcracking properties of such material. For this reason, structural codes introduce orientation factors which aim to correlate the real mechanical properties of the structural element with the ones determined from standard beams. Although the need of considering fiber orientation in design codes is commonly accepted, the orientation factors are still based on a limited number of research studies, raising the need to better determine fiber orientation to improve the current standards and support the design process of FRC elements. In this research, a steel fiber‐reinforced concrete (SFRC) with a hybrid system of macro and microfibers is steered into a broad range of fiber orientations and cast into standard beams. Besides measuring the mechanical performance of these SFRC beams, three different methods for assessing fiber orientation are employed, namely electromagnetic induction, image analysis, and micro‐computed tomography. The comparison between the outcomes of the different methods provides detailed information about the accuracy and suitability of each method, considering the corresponding domain of applicability at structural level. Finally, a critical review of the most common 2D and 3D orientation parameters found in literature is performed, and the equations are adapted to account for the hybrid system of fibers.\",\"PeriodicalId\":21988,\"journal\":{\"name\":\"Structural Concrete\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Concrete\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/suco.202400461\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Concrete","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/suco.202400461","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

纤维取向对纤维增强混凝土(FRC)结构件的设计至关重要,因为它对这种材料的开裂后性能有显著影响。因此,结构规范引入了取向系数,目的是将结构元件的实际机械性能与根据标准梁确定的机械性能联系起来。虽然在设计规范中考虑纤维取向的必要性已被普遍接受,但取向系数仍是基于有限的研究成果,因此需要更好地确定纤维取向,以改进现行标准,支持 FRC 构件的设计过程。在这项研究中,采用宏观和微观纤维混合系统的钢纤维增强混凝土(SFRC)被引导成多种纤维取向,并浇注到标准梁中。除了测量这些 SFRC 梁的力学性能外,还采用了三种不同的纤维取向评估方法,即电磁感应法、图像分析法和微计算机断层扫描法。通过比较不同方法的结果,可以详细了解每种方法的准确性和适用性,并考虑到结构层面的相应适用范围。最后,对文献中最常见的二维和三维取向参数进行了严格审查,并对方程进行了调整,以考虑到纤维的混合系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review
Fiber orientation is of paramount importance for the design of fiber‐reinforced concrete (FRC) structural elements, because it markedly influences the postcracking properties of such material. For this reason, structural codes introduce orientation factors which aim to correlate the real mechanical properties of the structural element with the ones determined from standard beams. Although the need of considering fiber orientation in design codes is commonly accepted, the orientation factors are still based on a limited number of research studies, raising the need to better determine fiber orientation to improve the current standards and support the design process of FRC elements. In this research, a steel fiber‐reinforced concrete (SFRC) with a hybrid system of macro and microfibers is steered into a broad range of fiber orientations and cast into standard beams. Besides measuring the mechanical performance of these SFRC beams, three different methods for assessing fiber orientation are employed, namely electromagnetic induction, image analysis, and micro‐computed tomography. The comparison between the outcomes of the different methods provides detailed information about the accuracy and suitability of each method, considering the corresponding domain of applicability at structural level. Finally, a critical review of the most common 2D and 3D orientation parameters found in literature is performed, and the equations are adapted to account for the hybrid system of fibers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Structural Concrete
Structural Concrete CONSTRUCTION & BUILDING TECHNOLOGY-ENGINEERING, CIVIL
CiteScore
5.60
自引率
15.60%
发文量
284
审稿时长
3 months
期刊介绍: Structural Concrete, the official journal of the fib, provides conceptual and procedural guidance in the field of concrete construction, and features peer-reviewed papers, keynote research and industry news covering all aspects of the design, construction, performance in service and demolition of concrete structures. Main topics: design, construction, performance in service, conservation (assessment, maintenance, strengthening) and demolition of concrete structures research about the behaviour of concrete structures development of design methods fib Model Code sustainability of concrete structures.
期刊最新文献
Development of a new analytical model for circular concrete ring segments with dry joints under combined effects Fiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review Load‐path analysis of transverse tensile stresses in multiple‐pile caps Mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending Experimental investigation on mechanical property and hydration process of sintered sludge cement paste at different water‐binder ratios and curing ages
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1