矫形器变形测试的可靠性和有效性

Q1 Mathematics Applied Sciences Pub Date : 2024-09-18 DOI:10.3390/app14188378
Alejandra Sierra-Rodríguez, Raúl J. Molines-Barroso, M. A. Martínez, Juana Abenojar-Buendía, José Luis Lázaro-Martínez, Angel M. Orejana-García
{"title":"矫形器变形测试的可靠性和有效性","authors":"Alejandra Sierra-Rodríguez, Raúl J. Molines-Barroso, M. A. Martínez, Juana Abenojar-Buendía, José Luis Lázaro-Martínez, Angel M. Orejana-García","doi":"10.3390/app14188378","DOIUrl":null,"url":null,"abstract":"The aim of this study was to evaluate the validity of an orthotic deformation test on insole arches and the impact of researcher expertise on the test’s reproducibility. Three researchers with different levels of experience evaluated orthotic deformation by applying a vertical force with their thumb on the dorsal surface of 48 polypropylene orthoses. An electromechanical test machine was used to evaluate the stiffness of the orthoses, and the results were compared with those of the orthotic deformation tests. Fleiss’ kappa and weighted kappa and Mann–Whitney U tests were used to evaluate the interobserver reliability and the validity, respectively. There was no consensus among the three researchers (Kappa = 0.080; p-value = 0.334), although the two researchers with higher levels of experience exhibited moderate consensus (Kappa = 0.52; p-value < 0.001). Orthoses characterised by a positive test suffered from more pronounced deformation when a constant vertical force was applied by the electromechanical test machine (5.62 [4.64–7.38] vs. 4.56 [3.59–5.28] mm; p-value = 0.003). The orthotic deformation test is valid for interpreting the degree of deformation of polypropylene custom orthoses when it is compared with an axial force from a compression-device test. However, considering the high dispersion of the results, it suggests that clinical experience is required to properly interpret the tests.","PeriodicalId":8224,"journal":{"name":"Applied Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability and Validity of the Orthotic Deformation Test\",\"authors\":\"Alejandra Sierra-Rodríguez, Raúl J. Molines-Barroso, M. A. Martínez, Juana Abenojar-Buendía, José Luis Lázaro-Martínez, Angel M. Orejana-García\",\"doi\":\"10.3390/app14188378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to evaluate the validity of an orthotic deformation test on insole arches and the impact of researcher expertise on the test’s reproducibility. Three researchers with different levels of experience evaluated orthotic deformation by applying a vertical force with their thumb on the dorsal surface of 48 polypropylene orthoses. An electromechanical test machine was used to evaluate the stiffness of the orthoses, and the results were compared with those of the orthotic deformation tests. Fleiss’ kappa and weighted kappa and Mann–Whitney U tests were used to evaluate the interobserver reliability and the validity, respectively. There was no consensus among the three researchers (Kappa = 0.080; p-value = 0.334), although the two researchers with higher levels of experience exhibited moderate consensus (Kappa = 0.52; p-value < 0.001). Orthoses characterised by a positive test suffered from more pronounced deformation when a constant vertical force was applied by the electromechanical test machine (5.62 [4.64–7.38] vs. 4.56 [3.59–5.28] mm; p-value = 0.003). The orthotic deformation test is valid for interpreting the degree of deformation of polypropylene custom orthoses when it is compared with an axial force from a compression-device test. However, considering the high dispersion of the results, it suggests that clinical experience is required to properly interpret the tests.\",\"PeriodicalId\":8224,\"journal\":{\"name\":\"Applied Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/app14188378\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/app14188378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估鞋垫拱形变形测试的有效性,以及研究人员的专业知识对测试可重复性的影响。三位具有不同经验水平的研究人员通过用拇指在 48 个聚丙烯矫形器的背侧表面施加垂直力来评估矫形器的变形情况。使用机电测试机评估矫形器的硬度,并将结果与矫形器变形测试结果进行比较。弗莱斯卡帕检验、加权卡帕检验和曼-惠特尼U检验分别用于评估观察者间的可靠性和有效性。三位研究人员之间没有达成共识(Kappa = 0.080;p 值 = 0.334),但两位经验丰富的研究人员表现出了中等程度的共识(Kappa = 0.52;p 值 < 0.001)。当机电测试机施加恒定的垂直力时,测试结果为阳性的矫形器会出现更明显的变形(5.62 [4.64-7.38] mm vs. 4.56 [3.59-5.28] mm;p 值 = 0.003)。当矫形器变形测试与压缩装置测试的轴向力进行比较时,可有效解释聚丙烯定制矫形器的变形程度。然而,考虑到结果的高度分散性,这表明正确解释测试需要临床经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability and Validity of the Orthotic Deformation Test
The aim of this study was to evaluate the validity of an orthotic deformation test on insole arches and the impact of researcher expertise on the test’s reproducibility. Three researchers with different levels of experience evaluated orthotic deformation by applying a vertical force with their thumb on the dorsal surface of 48 polypropylene orthoses. An electromechanical test machine was used to evaluate the stiffness of the orthoses, and the results were compared with those of the orthotic deformation tests. Fleiss’ kappa and weighted kappa and Mann–Whitney U tests were used to evaluate the interobserver reliability and the validity, respectively. There was no consensus among the three researchers (Kappa = 0.080; p-value = 0.334), although the two researchers with higher levels of experience exhibited moderate consensus (Kappa = 0.52; p-value < 0.001). Orthoses characterised by a positive test suffered from more pronounced deformation when a constant vertical force was applied by the electromechanical test machine (5.62 [4.64–7.38] vs. 4.56 [3.59–5.28] mm; p-value = 0.003). The orthotic deformation test is valid for interpreting the degree of deformation of polypropylene custom orthoses when it is compared with an axial force from a compression-device test. However, considering the high dispersion of the results, it suggests that clinical experience is required to properly interpret the tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Sciences
Applied Sciences Mathematics-Applied Mathematics
CiteScore
6.40
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊介绍: APPS is an international journal. APPS covers a wide spectrum of pure and applied mathematics in science and technology, promoting especially papers presented at Carpato-Balkan meetings. The Editorial Board of APPS takes a very active role in selecting and refereeing papers, ensuring the best quality of contemporary mathematics and its applications. APPS is abstracted in Zentralblatt für Mathematik. The APPS journal uses Double blind peer review.
期刊最新文献
The Effectiveness of Exercise Programs on Balance, Functional Ability, Quality of Life, and Depression in Progressive Supranuclear Palsy: A Case Study Application of Historical Comprehensive Multimodal Transportation Data for Testing the Commuting Time Paradox: Evidence from the Portland, OR Region Real-Time Optimization of Ancillary Service Allocation in Renewable Energy Microgrids Using Virtual Load Exploring the Association between Pro-Inflammation and the Early Diagnosis of Alzheimer’s Disease in Buccal Cells Using Immunocytochemistry and Machine Learning Techniques HumanEnerg Hotspot: Conceptual Design of an Agile Toolkit for Human Energy Reinforcement in Industry 5.0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1