诊断新生儿持续性肺动脉高压时的超声心动图指标

IF 1.7 4区 医学 Q3 OBSTETRICS & GYNECOLOGY Journal of Perinatal Medicine Pub Date : 2024-09-14 DOI:10.1515/jpm-2023-0346
Sujith S. Pereira, Xander Jacquemyn, Shelby Kutty
{"title":"诊断新生儿持续性肺动脉高压时的超声心动图指标","authors":"Sujith S. Pereira, Xander Jacquemyn, Shelby Kutty","doi":"10.1515/jpm-2023-0346","DOIUrl":null,"url":null,"abstract":"Objectives Clinical parameters along with echocardiographic markers are used to interrogate the haemodynamics in persistent pulmonary hypertension of the newborn (PPHN). The aim of this study was to compare different echocardiographic markers in recent cohort of newborn infants with and without PPHN. Methods In this retrospective study, common echocardiographic markers were examined in infants>34 weeks’ gestation with PPHN (cases) and without PPHN (controls). Infants with congenital heart disease were excluded. Binary regression testing was used to evaluate echocardiographic markers predicting PPHN and death. In addition, diagnostic accuracy testing of echocardiographic markers using ROC was also performed. Intra-observer reliability for echocardiographic markers was examined using coefficient of variation (CoV) and intraclass correlation. Results Fifty-two infants were studied; 22 (42 %) infants with PPHN had significantly higher oxygen requirement, oxygenation index and ventilation days when compared with controls. Echocardiographic markers such as TR Vmax, S/D TR, PAAT, TAPSE and eccentricity index (EI) were significantly different between cases and controls. Receiver operator characteristics analysis of echocardiographic markers revealed TR Vmax 0.96 (0.9–1.0), S/D TR 0.95 (0.87–1.0) and end systolic EI 0.94 (0.87–1.0). These markers were found to predict death in this cohort of infants. CoV and Intra-observer reliability was good for various echocardiographic markers. Conclusions Among the various echocardiographic markers studied, TR Vmax when present along with S/D TR and end systolic EI had good intra-observer reliability and were diagnostic of PPHN and predicted death in this cohort. Future trials could use these markers in studies examining PPHN.","PeriodicalId":16704,"journal":{"name":"Journal of Perinatal Medicine","volume":"1 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Echocardiographic markers at diagnosis of persistent pulmonary hypertension of the newborn\",\"authors\":\"Sujith S. Pereira, Xander Jacquemyn, Shelby Kutty\",\"doi\":\"10.1515/jpm-2023-0346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives Clinical parameters along with echocardiographic markers are used to interrogate the haemodynamics in persistent pulmonary hypertension of the newborn (PPHN). The aim of this study was to compare different echocardiographic markers in recent cohort of newborn infants with and without PPHN. Methods In this retrospective study, common echocardiographic markers were examined in infants>34 weeks’ gestation with PPHN (cases) and without PPHN (controls). Infants with congenital heart disease were excluded. Binary regression testing was used to evaluate echocardiographic markers predicting PPHN and death. In addition, diagnostic accuracy testing of echocardiographic markers using ROC was also performed. Intra-observer reliability for echocardiographic markers was examined using coefficient of variation (CoV) and intraclass correlation. Results Fifty-two infants were studied; 22 (42 %) infants with PPHN had significantly higher oxygen requirement, oxygenation index and ventilation days when compared with controls. Echocardiographic markers such as TR Vmax, S/D TR, PAAT, TAPSE and eccentricity index (EI) were significantly different between cases and controls. Receiver operator characteristics analysis of echocardiographic markers revealed TR Vmax 0.96 (0.9–1.0), S/D TR 0.95 (0.87–1.0) and end systolic EI 0.94 (0.87–1.0). These markers were found to predict death in this cohort of infants. CoV and Intra-observer reliability was good for various echocardiographic markers. Conclusions Among the various echocardiographic markers studied, TR Vmax when present along with S/D TR and end systolic EI had good intra-observer reliability and were diagnostic of PPHN and predicted death in this cohort. Future trials could use these markers in studies examining PPHN.\",\"PeriodicalId\":16704,\"journal\":{\"name\":\"Journal of Perinatal Medicine\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Perinatal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/jpm-2023-0346\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Perinatal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/jpm-2023-0346","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的 临床参数和超声心动图标记用于检查新生儿持续性肺动脉高压(PPHN)的血流动力学。本研究的目的是比较近期一组患有和未患有 PPHN 的新生儿的不同超声心动图指标。方法 在这项回顾性研究中,对妊娠 34 周的 PPHN 患儿(病例)和非 PPHN 患儿(对照组)的常见超声心动图指标进行了检查。患有先天性心脏病的婴儿被排除在外。二元回归测试用于评估预测 PPHN 和死亡的超声心动图标记物。此外,还使用 ROC 对超声心动图标记物的诊断准确性进行了测试。使用变异系数(CoV)和类内相关性检验超声心动图标记物在观察者内部的可靠性。结果 对52名婴儿进行了研究;与对照组相比,22名(42%)患有PPHN的婴儿的氧需求量、氧合作用指数和通气天数明显增加。病例和对照组之间的超声心动图指标,如 TR Vmax、S/D TR、PAAT、TAPSE 和偏心指数(EI),均有显著差异。超声心动图标记物的受体运算特征分析显示,TR Vmax为0.96(0.9-1.0),S/D TR为0.95(0.87-1.0),收缩末期EI为0.94(0.87-1.0)。这些指标可预测该组婴儿的死亡。各种超声心动图指标的CoV和观察者内部可靠性良好。结论 在所研究的各种超声心动图标记中,TR Vmax 与 S/D TR 和收缩末期 EI 同时存在时,观察者内部的可靠性较好,可诊断 PPHN 并预测该组婴儿的死亡。未来的试验可在研究 PPHN 时使用这些标记物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Echocardiographic markers at diagnosis of persistent pulmonary hypertension of the newborn
Objectives Clinical parameters along with echocardiographic markers are used to interrogate the haemodynamics in persistent pulmonary hypertension of the newborn (PPHN). The aim of this study was to compare different echocardiographic markers in recent cohort of newborn infants with and without PPHN. Methods In this retrospective study, common echocardiographic markers were examined in infants>34 weeks’ gestation with PPHN (cases) and without PPHN (controls). Infants with congenital heart disease were excluded. Binary regression testing was used to evaluate echocardiographic markers predicting PPHN and death. In addition, diagnostic accuracy testing of echocardiographic markers using ROC was also performed. Intra-observer reliability for echocardiographic markers was examined using coefficient of variation (CoV) and intraclass correlation. Results Fifty-two infants were studied; 22 (42 %) infants with PPHN had significantly higher oxygen requirement, oxygenation index and ventilation days when compared with controls. Echocardiographic markers such as TR Vmax, S/D TR, PAAT, TAPSE and eccentricity index (EI) were significantly different between cases and controls. Receiver operator characteristics analysis of echocardiographic markers revealed TR Vmax 0.96 (0.9–1.0), S/D TR 0.95 (0.87–1.0) and end systolic EI 0.94 (0.87–1.0). These markers were found to predict death in this cohort of infants. CoV and Intra-observer reliability was good for various echocardiographic markers. Conclusions Among the various echocardiographic markers studied, TR Vmax when present along with S/D TR and end systolic EI had good intra-observer reliability and were diagnostic of PPHN and predicted death in this cohort. Future trials could use these markers in studies examining PPHN.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Perinatal Medicine
Journal of Perinatal Medicine 医学-妇产科学
CiteScore
4.40
自引率
8.30%
发文量
183
审稿时长
4-8 weeks
期刊介绍: The Journal of Perinatal Medicine (JPM) is a truly international forum covering the entire field of perinatal medicine. It is an essential news source for all those obstetricians, neonatologists, perinatologists and allied health professionals who wish to keep abreast of progress in perinatal and related research. Ahead-of-print publishing ensures fastest possible knowledge transfer. The Journal provides statements on themes of topical interest as well as information and different views on controversial topics. It also informs about the academic, organisational and political aims and objectives of the World Association of Perinatal Medicine.
期刊最新文献
Placental fetal vascular malperfusion in maternal diabetes mellitus. Effects of a respiratory function indicator light on visual attention and ventilation quality during neonatal resuscitation: a randomised controlled crossover simulation trial. External validation of a non-invasive vaginal tool to assess the risk of intra-amniotic inflammation in pregnant women with preterm labor and intact membranes. The value of ultrasound spectra of middle cerebral artery and umbilical artery blood flow in adverse pregnancy outcomes. A family-centric, comprehensive nurse-led home oxygen programme for neonatal chronic lung disease: home oxygen policy evaluation (HOPE) study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1