{"title":"化学发光特征阵列与机器学习相结合用于阿尔茨海默病血清诊断","authors":"Chongzhao, Ran, Biyue, Zhu, Yanbo, Li, Jing, Zhang, Jun, Yang, Shi, Kuang, Johnson, Wang, Shiqian, Shen, Xuan, Zhai, Jiajun, Xie, Astra, Yu","doi":"10.26434/chemrxiv-2024-vs1m9","DOIUrl":null,"url":null,"abstract":"Tremendous efforts have been made to directly identify serum components using traditional omics approaches. However, several unmet medical needs persist, particularly for chronic diseases that lack reliable biomarkers. The subtle physicochemical abnormality of serum has been widely overlooked and currently lacks detection methods. Inspired by the bat echolocation mechanism, we proposed a chemiluminescence “echoes” approach to depict the disease-specific signatures in biofluids. Specifically, Alzheimer’s disease (AD) serums were used for proof-of-concept study. We first demonstrated the discrepancy in physicochemical properties between AD and healthy control (HC) serums. On this basis, we developed a simple, fast and versatile UNICODE (UNiversal Interaction of Chemiluminescence echOes for Disease Evaluation) array for AD diagnosis. By employing a \"bat\" probe (ADLumin-1), which generates chemiluminescence autonomously, and combined with a panel of “flag” molecules that enable “echo” formation, we were able to create distinct signatures for various serum components and subtle physicochemical environments. To develop an AD-specific UNICODE diagnosis, we screened a library of over 1000 small molecules, and identified 12 “flag” molecules (top-12) that optimally depict the differences between AD and HC serums. Finally, we used the top-12 array for AD diagnosis. By modeling the UNICODE signatures with seven machine learning methods, we successfully differentiated AD (n = 31) and HC (n = 37) serums, and our best model of random forest provided accuracy = 85.48%, precision = 85.00%, recall = 88.60%, f1 = 85.63%, and AUC = 90.24%. Our strategy could provide new insights into biofluid abnormality and prototype tools for developing liquid biopsy diagnoses for AD and other diseases.","PeriodicalId":9813,"journal":{"name":"ChemRxiv","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Chemiluminescence signature arrays coupling with machine learning for Alzheimer’s disease serum diagnosis\",\"authors\":\"Chongzhao, Ran, Biyue, Zhu, Yanbo, Li, Jing, Zhang, Jun, Yang, Shi, Kuang, Johnson, Wang, Shiqian, Shen, Xuan, Zhai, Jiajun, Xie, Astra, Yu\",\"doi\":\"10.26434/chemrxiv-2024-vs1m9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tremendous efforts have been made to directly identify serum components using traditional omics approaches. However, several unmet medical needs persist, particularly for chronic diseases that lack reliable biomarkers. The subtle physicochemical abnormality of serum has been widely overlooked and currently lacks detection methods. Inspired by the bat echolocation mechanism, we proposed a chemiluminescence “echoes” approach to depict the disease-specific signatures in biofluids. Specifically, Alzheimer’s disease (AD) serums were used for proof-of-concept study. We first demonstrated the discrepancy in physicochemical properties between AD and healthy control (HC) serums. On this basis, we developed a simple, fast and versatile UNICODE (UNiversal Interaction of Chemiluminescence echOes for Disease Evaluation) array for AD diagnosis. By employing a \\\"bat\\\" probe (ADLumin-1), which generates chemiluminescence autonomously, and combined with a panel of “flag” molecules that enable “echo” formation, we were able to create distinct signatures for various serum components and subtle physicochemical environments. To develop an AD-specific UNICODE diagnosis, we screened a library of over 1000 small molecules, and identified 12 “flag” molecules (top-12) that optimally depict the differences between AD and HC serums. Finally, we used the top-12 array for AD diagnosis. By modeling the UNICODE signatures with seven machine learning methods, we successfully differentiated AD (n = 31) and HC (n = 37) serums, and our best model of random forest provided accuracy = 85.48%, precision = 85.00%, recall = 88.60%, f1 = 85.63%, and AUC = 90.24%. Our strategy could provide new insights into biofluid abnormality and prototype tools for developing liquid biopsy diagnoses for AD and other diseases.\",\"PeriodicalId\":9813,\"journal\":{\"name\":\"ChemRxiv\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ChemRxiv\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26434/chemrxiv-2024-vs1m9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ChemRxiv","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26434/chemrxiv-2024-vs1m9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在利用传统的全息方法直接鉴定血清成分方面,人们已经做出了巨大的努力。然而,一些尚未满足的医疗需求依然存在,尤其是缺乏可靠生物标志物的慢性疾病。血清中微妙的物理化学异常一直被广泛忽视,目前也缺乏检测方法。受蝙蝠回声定位机制的启发,我们提出了一种化学发光 "回声 "方法来描述生物液体中的疾病特异性特征。具体来说,我们使用阿尔茨海默病(AD)血清进行概念验证研究。我们首先证明了阿尔茨海默病(AD)血清与健康对照(HC)血清在理化性质上的差异。在此基础上,我们开发了一种用于诊断 AD 的简单、快速和多功能的 UNICODE(用于疾病评估的化学发光回声通用相互作用)阵列。通过使用能自主产生化学发光的 "蝙蝠 "探针(ADLumin-1),并结合能形成 "回声 "的 "标志 "分子,我们能够为各种血清成分和微妙的理化环境创建独特的特征。为了开发出针对 AD 的 UNICODE 诊断方法,我们筛选了一个包含 1000 多种小分子的库,并确定了 12 个 "标志 "分子(top-12),它们能最佳地描述 AD 血清和 HC 血清之间的差异。最后,我们将前 12 个分子阵列用于 AD 诊断。通过使用七种机器学习方法对UNICODE特征建模,我们成功地区分了AD(n = 31)和HC(n = 37)血清,最佳随机森林模型的准确率为85.48%,精确率为85.00%,召回率为88.60%,f1 = 85.63%,AUC = 90.24%。我们的策略可以为生物流体异常提供新的见解,并为开发针对AD和其他疾病的液体活检诊断原型工具提供新的思路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Chemiluminescence signature arrays coupling with machine learning for Alzheimer’s disease serum diagnosis
Tremendous efforts have been made to directly identify serum components using traditional omics approaches. However, several unmet medical needs persist, particularly for chronic diseases that lack reliable biomarkers. The subtle physicochemical abnormality of serum has been widely overlooked and currently lacks detection methods. Inspired by the bat echolocation mechanism, we proposed a chemiluminescence “echoes” approach to depict the disease-specific signatures in biofluids. Specifically, Alzheimer’s disease (AD) serums were used for proof-of-concept study. We first demonstrated the discrepancy in physicochemical properties between AD and healthy control (HC) serums. On this basis, we developed a simple, fast and versatile UNICODE (UNiversal Interaction of Chemiluminescence echOes for Disease Evaluation) array for AD diagnosis. By employing a "bat" probe (ADLumin-1), which generates chemiluminescence autonomously, and combined with a panel of “flag” molecules that enable “echo” formation, we were able to create distinct signatures for various serum components and subtle physicochemical environments. To develop an AD-specific UNICODE diagnosis, we screened a library of over 1000 small molecules, and identified 12 “flag” molecules (top-12) that optimally depict the differences between AD and HC serums. Finally, we used the top-12 array for AD diagnosis. By modeling the UNICODE signatures with seven machine learning methods, we successfully differentiated AD (n = 31) and HC (n = 37) serums, and our best model of random forest provided accuracy = 85.48%, precision = 85.00%, recall = 88.60%, f1 = 85.63%, and AUC = 90.24%. Our strategy could provide new insights into biofluid abnormality and prototype tools for developing liquid biopsy diagnoses for AD and other diseases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Exascale Quantum Mechanical Simulations: Navigating the Shifting Sands of Hardware and Software Hybrid synthesis of AMFC-derived amides using supported gold nanoparticles and acyl-coenzyme A ligases Non-covalent spin labelling of TRPC5 ion channels enables EPR studies of protein-ligand interactions An Efficient RI-MP2 Algorithm for Distributed Many-GPU Architectures Unusual Confinement-Induced Basicity and Proton-Mediated CH Activity of an Adipic Acid-Ammonium Cluster
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1