有关心房颤动脉冲场消融术安全性的考虑因素

IF 2.5 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Heart Rhythm O2 Pub Date : 2024-09-01 DOI:10.1016/j.hroo.2024.08.002
{"title":"有关心房颤动脉冲场消融术安全性的考虑因素","authors":"","doi":"10.1016/j.hroo.2024.08.002","DOIUrl":null,"url":null,"abstract":"<div><p>The introduction of pulsed field ablation (PFA) in electrophysiology marks a significant advancement, promising efficacy comparable to thermal ablation methods while potentially providing safety advantages. Despite a generally favorable safety profile in human trials and postmarket registries, cautious evaluation of PFA's safety is essential. This review provides a comprehensive overview of key safety considerations as we discuss a myriad of considerations ranging from thermal effects, gaseous microbubble formation, muscle contractions, and proarrhythmia to procedural techniques. We explore specific safety concerns with phrenic nerve injury, cerebral lesions, coronary artery spasm, hemolysis and pulmonary bleeding. Vigilance in safety monitoring, coupled with advancements in procedural techniques and understanding of PFA's unique effects, is crucial for optimizing the safe and effective use of PFA.</p></div>","PeriodicalId":29772,"journal":{"name":"Heart Rhythm O2","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666501824002617/pdfft?md5=d7e12bb800ab1a21c10d904cab849131&pid=1-s2.0-S2666501824002617-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Considerations regarding safety with pulsed field ablation for atrial fibrillation\",\"authors\":\"\",\"doi\":\"10.1016/j.hroo.2024.08.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The introduction of pulsed field ablation (PFA) in electrophysiology marks a significant advancement, promising efficacy comparable to thermal ablation methods while potentially providing safety advantages. Despite a generally favorable safety profile in human trials and postmarket registries, cautious evaluation of PFA's safety is essential. This review provides a comprehensive overview of key safety considerations as we discuss a myriad of considerations ranging from thermal effects, gaseous microbubble formation, muscle contractions, and proarrhythmia to procedural techniques. We explore specific safety concerns with phrenic nerve injury, cerebral lesions, coronary artery spasm, hemolysis and pulmonary bleeding. Vigilance in safety monitoring, coupled with advancements in procedural techniques and understanding of PFA's unique effects, is crucial for optimizing the safe and effective use of PFA.</p></div>\",\"PeriodicalId\":29772,\"journal\":{\"name\":\"Heart Rhythm O2\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666501824002617/pdfft?md5=d7e12bb800ab1a21c10d904cab849131&pid=1-s2.0-S2666501824002617-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart Rhythm O2\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666501824002617\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart Rhythm O2","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666501824002617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

脉冲场消融术(PFA)在电生理学领域的引入标志着一项重大进步,其疗效有望与热消融方法相媲美,同时还具有潜在的安全性优势。尽管人体试验和上市后登记的安全性总体良好,但谨慎评估 PFA 的安全性至关重要。本综述全面概述了主要的安全性考虑因素,我们讨论了从热效应、气态微泡形成、肌肉收缩、前心律失常到手术技术等一系列考虑因素。我们还探讨了膈神经损伤、脑损伤、冠状动脉痉挛、溶血和肺出血等具体的安全问题。对安全监控的警惕,加上手术技术的进步和对 PFA 独特作用的了解,对于优化 PFA 的安全有效使用至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Considerations regarding safety with pulsed field ablation for atrial fibrillation

The introduction of pulsed field ablation (PFA) in electrophysiology marks a significant advancement, promising efficacy comparable to thermal ablation methods while potentially providing safety advantages. Despite a generally favorable safety profile in human trials and postmarket registries, cautious evaluation of PFA's safety is essential. This review provides a comprehensive overview of key safety considerations as we discuss a myriad of considerations ranging from thermal effects, gaseous microbubble formation, muscle contractions, and proarrhythmia to procedural techniques. We explore specific safety concerns with phrenic nerve injury, cerebral lesions, coronary artery spasm, hemolysis and pulmonary bleeding. Vigilance in safety monitoring, coupled with advancements in procedural techniques and understanding of PFA's unique effects, is crucial for optimizing the safe and effective use of PFA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Heart Rhythm O2
Heart Rhythm O2 Cardiology and Cardiovascular Medicine
CiteScore
3.30
自引率
0.00%
发文量
0
审稿时长
52 days
期刊最新文献
A model for the development of cardiac implantable electronic device services in countries lacking such services A prospective, multicenter, randomized controlled trial comparing VDD-ICD with VVI-ICD in detecting subclinical atrial fibrillation in patients with ICDs: The Dx-AF trial Risk factors and incidence of new-onset heart failure with conventional pacemaker implant: A nationwide study Outcomes of patients with malignancy undergoing catheter ablation for ventricular tachycardia in the United States Remarkably high and accelerating failure rate of a widely used implantable cardioverter-defibrillator lead: A large-scale manufacturer-independent multicenter study with long accurate follow-up
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1