{"title":"无标记高通量阻抗激活细胞分拣技术","authors":"Kui Zhang, Ziyang Xia, Yiming Wang, Lisheng Zheng, Baoqing Li and Jiaru Chu","doi":"10.1039/D4LC00487F","DOIUrl":null,"url":null,"abstract":"<p >Cell sorting holds broad applications in fields such as early cancer diagnosis, cell differentiation studies, drug screening, and single-cell sequencing. However, achieving high-throughput and high-purity in label-free single-cell sorting is challenging. To overcome this issue, we propose a label-free, high-throughput, and high-accuracy impedance-activated cell sorting system based on impedance detection and dual membrane pumps. Leveraging the low-latency characteristics of FPGA, the system facilitates real-time dual-frequency single-cell impedance detection with high-throughput (5 × 10<small><sup>4</sup></small> cells per s) for HeLa, MDA-MB-231, and Jurkat cells. Furthermore, the system accomplishes low-latency (less than 0.3 ms), label-free, high-throughput (1000 particles per s) and high-accuracy (almost 99%) single-particle sorting using FPGA-based high-precision sort-timing prediction. In experiments with Jurkat and MDA-MB-231 cells, the system achieved a throughput of up to 1000 cells per s, maintaining a pre-sorting purity of 28.57% and increasing post-sorting purity to 97.09%. These findings indicate that our system holds significant potential for applications in label-free, high-throughput cell sorting.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":null,"pages":null},"PeriodicalIF":6.1000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Label-free high-throughput impedance-activated cell sorting†\",\"authors\":\"Kui Zhang, Ziyang Xia, Yiming Wang, Lisheng Zheng, Baoqing Li and Jiaru Chu\",\"doi\":\"10.1039/D4LC00487F\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Cell sorting holds broad applications in fields such as early cancer diagnosis, cell differentiation studies, drug screening, and single-cell sequencing. However, achieving high-throughput and high-purity in label-free single-cell sorting is challenging. To overcome this issue, we propose a label-free, high-throughput, and high-accuracy impedance-activated cell sorting system based on impedance detection and dual membrane pumps. Leveraging the low-latency characteristics of FPGA, the system facilitates real-time dual-frequency single-cell impedance detection with high-throughput (5 × 10<small><sup>4</sup></small> cells per s) for HeLa, MDA-MB-231, and Jurkat cells. Furthermore, the system accomplishes low-latency (less than 0.3 ms), label-free, high-throughput (1000 particles per s) and high-accuracy (almost 99%) single-particle sorting using FPGA-based high-precision sort-timing prediction. In experiments with Jurkat and MDA-MB-231 cells, the system achieved a throughput of up to 1000 cells per s, maintaining a pre-sorting purity of 28.57% and increasing post-sorting purity to 97.09%. These findings indicate that our system holds significant potential for applications in label-free, high-throughput cell sorting.</p>\",\"PeriodicalId\":85,\"journal\":{\"name\":\"Lab on a Chip\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lab on a Chip\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00487f\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00487f","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

细胞分拣在早期癌症诊断、细胞分化研究、药物筛选和单细胞测序等领域有着广泛的应用。然而,在无标记单细胞分选中实现高通量和高纯度具有挑战性。为了克服这一问题,我们提出了一种基于阻抗检测和双膜泵的无标记、高通量和高精度阻抗激活细胞分拣系统。利用 FPGA 的低延迟特性,该系统可对 Hela、MDA-MB-231 和 Jurkat 细胞进行高通量(5 × 104 cells/s)的实时双频单细胞阻抗检测。此外,该系统还利用基于 FPGA 的高精度分拣时间预测,实现了低延迟(小于 0.3 毫秒)、无标记、高通量(1,000 颗粒/秒)和高准确度(近 99%)的单颗粒分拣。在对 Jurkat 和 MDA-MB-231 细胞的实验中,该系统实现了高达 1,000 cells/s 的吞吐量,分选前纯度保持在 28.57%,分选后纯度提高到 97.09%。这些研究结果表明,我们的系统在无标记、高通量细胞分选方面具有巨大的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Label-free high-throughput impedance-activated cell sorting†

Cell sorting holds broad applications in fields such as early cancer diagnosis, cell differentiation studies, drug screening, and single-cell sequencing. However, achieving high-throughput and high-purity in label-free single-cell sorting is challenging. To overcome this issue, we propose a label-free, high-throughput, and high-accuracy impedance-activated cell sorting system based on impedance detection and dual membrane pumps. Leveraging the low-latency characteristics of FPGA, the system facilitates real-time dual-frequency single-cell impedance detection with high-throughput (5 × 104 cells per s) for HeLa, MDA-MB-231, and Jurkat cells. Furthermore, the system accomplishes low-latency (less than 0.3 ms), label-free, high-throughput (1000 particles per s) and high-accuracy (almost 99%) single-particle sorting using FPGA-based high-precision sort-timing prediction. In experiments with Jurkat and MDA-MB-231 cells, the system achieved a throughput of up to 1000 cells per s, maintaining a pre-sorting purity of 28.57% and increasing post-sorting purity to 97.09%. These findings indicate that our system holds significant potential for applications in label-free, high-throughput cell sorting.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
期刊最新文献
Observing root growth and signalling responses to stress gradients and pathogens using the bi-directional dual-flow RootChip Optical tweezer-assisted cell pairing and fusion for somatic cell nuclear transfer within an open microchannel. Microstring-engineered tension tissues: A novel platform for replicating tissue mechanics and advancing mechanobiology Discretised microfluidics for noninvasive health monitoring using sweat sensing Inside back cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1