脊髓损伤患者对瓦尔萨尔瓦手法的反应与血管收缩能力没有广泛关系。

IF 3.9 3区 医学 Q1 CLINICAL NEUROLOGY Clinical Autonomic Research Pub Date : 2024-12-01 Epub Date: 2024-09-19 DOI:10.1007/s10286-024-01060-1
Kathryn Burns, Adina E Draghici, J Andrew Taylor
{"title":"脊髓损伤患者对瓦尔萨尔瓦手法的反应与血管收缩能力没有广泛关系。","authors":"Kathryn Burns, Adina E Draghici, J Andrew Taylor","doi":"10.1007/s10286-024-01060-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A blood pressure stabilization during late phase II of Valsalva's maneuver may be utilized to confirm sympathetic vasoconstrictor control after a spinal cord injury. This study investigated whether Valsalva response was predictive of hemodynamics during tilt or isometric handgrip.</p><p><strong>Methods: </strong>Presence/absence of Valsalva response was compared to heart rate, mean arterial pressure, leg blood flow, and vascular resistance during head-up tilt and isometric handgrip to fatigue in 14 adults with spinal cord injury from C7 to T12 and 14 controls. Statistics were performed with two-way repeated measure analysis of variance (ANOVA), post hoc t-tests for between-group comparisons, and Mann-Whitney U tests for within-group.</p><p><strong>Results: </strong>In total, six participants with spinal cord injury lacked a blood pressure stabilization for Valsalva's maneuver. However, this was not related to vasoconstrictor responses during the other tests. The groups had similar heart rate and blood pressure changes during tilt, though leg blood flow decreases and vascular resistance increases tended to be smaller at 20° tilt in those with spinal cord injury (p = 0.07 and p = 0.11, respectively). Participants with spinal cord injury had lower heart rates and markedly smaller blood pressure increases during handgrip (both p < 0.05). There were no group differences in leg blood flow, but those with spinal cord injury demonstrated a blunted vascular resistance increase by the final 10% of the handgrip (p < 0.01).</p><p><strong>Conclusions: </strong>Valsalva response was not consistent with hemodynamics during other stimuli, but some individuals evidence increases in sub-lesional vascular resistance to isometric handgrip comparable to controls, suggesting a sympathoexcitatory stimulus may be critical to provoke hemodynamic responses after spinal cord injury.</p>","PeriodicalId":10168,"journal":{"name":"Clinical Autonomic Research","volume":" ","pages":"571-581"},"PeriodicalIF":3.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Responses to Valsalva's maneuver in spinal cord injury do not broadly relate to vasoconstrictor capacity.\",\"authors\":\"Kathryn Burns, Adina E Draghici, J Andrew Taylor\",\"doi\":\"10.1007/s10286-024-01060-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>A blood pressure stabilization during late phase II of Valsalva's maneuver may be utilized to confirm sympathetic vasoconstrictor control after a spinal cord injury. This study investigated whether Valsalva response was predictive of hemodynamics during tilt or isometric handgrip.</p><p><strong>Methods: </strong>Presence/absence of Valsalva response was compared to heart rate, mean arterial pressure, leg blood flow, and vascular resistance during head-up tilt and isometric handgrip to fatigue in 14 adults with spinal cord injury from C7 to T12 and 14 controls. Statistics were performed with two-way repeated measure analysis of variance (ANOVA), post hoc t-tests for between-group comparisons, and Mann-Whitney U tests for within-group.</p><p><strong>Results: </strong>In total, six participants with spinal cord injury lacked a blood pressure stabilization for Valsalva's maneuver. However, this was not related to vasoconstrictor responses during the other tests. The groups had similar heart rate and blood pressure changes during tilt, though leg blood flow decreases and vascular resistance increases tended to be smaller at 20° tilt in those with spinal cord injury (p = 0.07 and p = 0.11, respectively). Participants with spinal cord injury had lower heart rates and markedly smaller blood pressure increases during handgrip (both p < 0.05). There were no group differences in leg blood flow, but those with spinal cord injury demonstrated a blunted vascular resistance increase by the final 10% of the handgrip (p < 0.01).</p><p><strong>Conclusions: </strong>Valsalva response was not consistent with hemodynamics during other stimuli, but some individuals evidence increases in sub-lesional vascular resistance to isometric handgrip comparable to controls, suggesting a sympathoexcitatory stimulus may be critical to provoke hemodynamic responses after spinal cord injury.</p>\",\"PeriodicalId\":10168,\"journal\":{\"name\":\"Clinical Autonomic Research\",\"volume\":\" \",\"pages\":\"571-581\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Autonomic Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10286-024-01060-1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Autonomic Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10286-024-01060-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:Valsalva 动作晚期第二阶段的血压稳定可用于确认脊髓损伤后交感血管收缩控制。本研究调查了 Valsalva 反应是否能预测倾斜或等长握手时的血液动力学:将 14 名 C7 至 T12 段脊髓损伤的成人和 14 名对照者在仰卧和等长握手至疲劳时的心率、平均动脉压、腿部血流量和血管阻力与 Valsalva 反应的有/无进行比较。统计采用双向重复测量方差分析(ANOVA),组间比较采用事后 t 检验,组内比较采用 Mann-Whitney U 检验:结果:共有六名脊髓损伤患者在做瓦尔萨尔瓦动作时血压不稳定。然而,这与其他测试中的血管收缩反应无关。在倾斜过程中,两组的心率和血压变化相似,但脊髓损伤者在倾斜 20° 时腿部血流减少和血管阻力增加的幅度较小(分别为 p = 0.07 和 p = 0.11)。脊髓损伤的参与者在握手时心率较低,血压升高幅度明显较小(均为 p 结论:脊髓损伤的参与者在握手时心率较低,血压升高幅度明显较小(均为 p瓦尔萨尔瓦反应与其他刺激时的血流动力学不一致,但有些人在等长握手时区域下血管阻力的增加与对照组相当,这表明交感兴奋刺激可能是脊髓损伤后引起血流动力学反应的关键。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Responses to Valsalva's maneuver in spinal cord injury do not broadly relate to vasoconstrictor capacity.

Purpose: A blood pressure stabilization during late phase II of Valsalva's maneuver may be utilized to confirm sympathetic vasoconstrictor control after a spinal cord injury. This study investigated whether Valsalva response was predictive of hemodynamics during tilt or isometric handgrip.

Methods: Presence/absence of Valsalva response was compared to heart rate, mean arterial pressure, leg blood flow, and vascular resistance during head-up tilt and isometric handgrip to fatigue in 14 adults with spinal cord injury from C7 to T12 and 14 controls. Statistics were performed with two-way repeated measure analysis of variance (ANOVA), post hoc t-tests for between-group comparisons, and Mann-Whitney U tests for within-group.

Results: In total, six participants with spinal cord injury lacked a blood pressure stabilization for Valsalva's maneuver. However, this was not related to vasoconstrictor responses during the other tests. The groups had similar heart rate and blood pressure changes during tilt, though leg blood flow decreases and vascular resistance increases tended to be smaller at 20° tilt in those with spinal cord injury (p = 0.07 and p = 0.11, respectively). Participants with spinal cord injury had lower heart rates and markedly smaller blood pressure increases during handgrip (both p < 0.05). There were no group differences in leg blood flow, but those with spinal cord injury demonstrated a blunted vascular resistance increase by the final 10% of the handgrip (p < 0.01).

Conclusions: Valsalva response was not consistent with hemodynamics during other stimuli, but some individuals evidence increases in sub-lesional vascular resistance to isometric handgrip comparable to controls, suggesting a sympathoexcitatory stimulus may be critical to provoke hemodynamic responses after spinal cord injury.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Autonomic Research
Clinical Autonomic Research 医学-临床神经学
CiteScore
7.40
自引率
6.90%
发文量
65
审稿时长
>12 weeks
期刊介绍: Clinical Autonomic Research aims to draw together and disseminate research work from various disciplines and specialties dealing with clinical problems resulting from autonomic dysfunction. Areas to be covered include: cardiovascular system, neurology, diabetes, endocrinology, urology, pain disorders, ophthalmology, gastroenterology, toxicology and clinical pharmacology, skin infectious diseases, renal disease. This journal is an essential source of new information for everyone working in areas involving the autonomic nervous system. A major feature of Clinical Autonomic Research is its speed of publication coupled with the highest refereeing standards.
期刊最新文献
Comment to the article titled: sympathetic dysfunction as an early indicator of autonomic involvement in Parkinson's disease. Autonomic failure associated with 16p11.2 duplication in two siblings. Adiposity and cardiac autonomic function in children with a family history of obesity. Responses to Valsalva's maneuver in spinal cord injury do not broadly relate to vasoconstrictor capacity. The insular cortex, autonomic asymmetry and cardiovascular control: looking at the right side of stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1