一名高安动脉炎患者在重做主动脉瓣置换手术后主动脉夹层延伸至室间隔:罕见病例报告。

IF 0.7 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS European Heart Journal: Case Reports Pub Date : 2024-09-10 eCollection Date: 2024-09-01 DOI:10.1093/ehjcr/ytae496
Chan-Han Hu, Chun-Hao Chang, Meng-Ta Tsai, Wei-Chuan Tsai, Mu-Shiang Huang
{"title":"一名高安动脉炎患者在重做主动脉瓣置换手术后主动脉夹层延伸至室间隔:罕见病例报告。","authors":"Chan-Han Hu, Chun-Hao Chang, Meng-Ta Tsai, Wei-Chuan Tsai, Mu-Shiang Huang","doi":"10.1093/ehjcr/ytae496","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Takayasu's arteritis is an infrequent manifestation of vasculitis affecting the aorta and its primary branches with numerous symptoms. This report details a rare case wherein a patient developed interventricular septal dissection following aortic valve replacement.</p><p><strong>Case summary: </strong>A middle-aged woman diagnosed with Takayasu's arteritis previously underwent aortic valve replacement with a mechanical valve owing to severe aortic regurgitation. Subsequently, she received a redo aortic valve replacement following an episode of prosthetic valve infective endocarditis with paravalvular leak. Heart failure symptoms emerged during follow-up, revealing aortic root dissection extending into the interventricular septum, causing significant prosthetic valve movement. A Trido Bentall operation and interventricular septum repair were performed, and the patient recovered smoothly.</p><p><strong>Discussion: </strong>Interventricular dissection, although uncommon, may be due to factors such as infection, myocardial infarction, congenital anomalies, trauma, or post-surgical shear stress. Timely diagnosis is imperative to prevent life-threatening complications; surgery remains the primary treatment. The present case report describes a rare presentation that was successfully managed through a Bentall operation and underscores the necessity of prompt intervention in treating this condition.</p>","PeriodicalId":11910,"journal":{"name":"European Heart Journal: Case Reports","volume":"8 9","pages":"ytae496"},"PeriodicalIF":0.7000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413577/pdf/","citationCount":"0","resultStr":"{\"title\":\"Aortic dissection extending into the interventricular septum following redo aortic valve replacement surgery in a patient with Takayasu's arteritis: a rare case report.\",\"authors\":\"Chan-Han Hu, Chun-Hao Chang, Meng-Ta Tsai, Wei-Chuan Tsai, Mu-Shiang Huang\",\"doi\":\"10.1093/ehjcr/ytae496\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Takayasu's arteritis is an infrequent manifestation of vasculitis affecting the aorta and its primary branches with numerous symptoms. This report details a rare case wherein a patient developed interventricular septal dissection following aortic valve replacement.</p><p><strong>Case summary: </strong>A middle-aged woman diagnosed with Takayasu's arteritis previously underwent aortic valve replacement with a mechanical valve owing to severe aortic regurgitation. Subsequently, she received a redo aortic valve replacement following an episode of prosthetic valve infective endocarditis with paravalvular leak. Heart failure symptoms emerged during follow-up, revealing aortic root dissection extending into the interventricular septum, causing significant prosthetic valve movement. A Trido Bentall operation and interventricular septum repair were performed, and the patient recovered smoothly.</p><p><strong>Discussion: </strong>Interventricular dissection, although uncommon, may be due to factors such as infection, myocardial infarction, congenital anomalies, trauma, or post-surgical shear stress. Timely diagnosis is imperative to prevent life-threatening complications; surgery remains the primary treatment. The present case report describes a rare presentation that was successfully managed through a Bentall operation and underscores the necessity of prompt intervention in treating this condition.</p>\",\"PeriodicalId\":11910,\"journal\":{\"name\":\"European Heart Journal: Case Reports\",\"volume\":\"8 9\",\"pages\":\"ytae496\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413577/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Heart Journal: Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/ehjcr/ytae496\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal: Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:高安动脉炎是一种不常见的血管炎表现,会影响主动脉及其主要分支,并伴有多种症状。本报告详细介绍了一例罕见病例,患者在主动脉瓣置换术后发生室间隔夹层。病例摘要:一名被诊断患有高安市动脉炎的中年女性曾因主动脉瓣严重反流而接受过主动脉瓣置换术,置换的是一个机械瓣。随后,她因人工瓣膜感染性心内膜炎并伴有瓣膜旁漏而接受了主动脉瓣置换术。随访期间出现了心衰症状,发现主动脉根部夹层延伸至室间隔,导致人工瓣膜明显移动。经过特里多-本托尔手术和室间隔修补术,患者顺利康复:讨论:室间隔夹层虽然并不常见,但可能由感染、心肌梗死、先天性异常、外伤或手术后剪切应力等因素引起。及时诊断是防止危及生命的并发症的当务之急;手术仍是主要的治疗方法。本病例报告描述了一个罕见的病例,该病例通过 Bentall 手术成功治愈,并强调了及时干预治疗这种疾病的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Aortic dissection extending into the interventricular septum following redo aortic valve replacement surgery in a patient with Takayasu's arteritis: a rare case report.

Background: Takayasu's arteritis is an infrequent manifestation of vasculitis affecting the aorta and its primary branches with numerous symptoms. This report details a rare case wherein a patient developed interventricular septal dissection following aortic valve replacement.

Case summary: A middle-aged woman diagnosed with Takayasu's arteritis previously underwent aortic valve replacement with a mechanical valve owing to severe aortic regurgitation. Subsequently, she received a redo aortic valve replacement following an episode of prosthetic valve infective endocarditis with paravalvular leak. Heart failure symptoms emerged during follow-up, revealing aortic root dissection extending into the interventricular septum, causing significant prosthetic valve movement. A Trido Bentall operation and interventricular septum repair were performed, and the patient recovered smoothly.

Discussion: Interventricular dissection, although uncommon, may be due to factors such as infection, myocardial infarction, congenital anomalies, trauma, or post-surgical shear stress. Timely diagnosis is imperative to prevent life-threatening complications; surgery remains the primary treatment. The present case report describes a rare presentation that was successfully managed through a Bentall operation and underscores the necessity of prompt intervention in treating this condition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Heart Journal: Case Reports
European Heart Journal: Case Reports Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.30
自引率
10.00%
发文量
451
审稿时长
14 weeks
期刊最新文献
Spinal myoclonus post-CRT-D implantation: a rare case report of iodinated contrast neurotoxicity. Transcatheter tricuspid valve replacement in arrhythmogenic right ventricular cardiomyopathy after prior cardioband annuloplasty: insights from the first-in-man case report. Trauma-triggered coronary embolism causing extensive anterolateral ST-segment elevation myocardial infarction in a young man with a mechanical aortic valve: a case report. Diagnostic challenge of mitral regurgitation caused by concomitant coronary obstruction and dynamic left ventricular outflow tract obstruction after transcatheter aortic valve replacement: a case report. Elucidating the course of an anomalous left anterior descending artery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1