羊膜移植治疗难治性黄斑孔的疗效--光学相干断层扫描和自动荧光长期研究。

Helena Proença, Marília Antunes, Joana Tavares Ferreira, Paula Magro, Mun Faria, Carlos Marques-Neves
{"title":"羊膜移植治疗难治性黄斑孔的疗效--光学相干断层扫描和自动荧光长期研究。","authors":"Helena Proença, Marília Antunes, Joana Tavares Ferreira, Paula Magro, Mun Faria, Carlos Marques-Neves","doi":"10.1007/s00417-024-06609-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze anatomical and functional outcomes of cryopreserved human amniotic membrane (hAM) transplant in refractory macular hole (MH) surgery, present retinal layers structure after MH closure, identify visual acuity improvement determinants and complication rate.</p><p><strong>Methods: </strong>Prospective and interventional case series including seventeen patients: 13 refractory and 4 chronic (8, 15, 18 and 30-years) MH. All patients underwent vitrectomy, hAM subretinal transplant, tamponade and positioning. Complete ophthalmological examination, axial length, best-corrected visual acuity, retinography, optical coherence tomography (OCT) and autofluorescence were recorded.</p><p><strong>Results: </strong>Mean follow-up was 31 months (range 6-53). Mean LogMAR visual acuity (1.71 ± 0.42) improved significantly (1.13 ± 0.41) (P < 0.001). Patients with better baseline BCVA ended up with better final BCVA (P = 0.018). Mean MH minimum linear diameter was 831 ± 252 μm and base diameter was 1409 ± 358 μm. MH closed in all patients. Transitory ocular hypertension in one patient and transient vitreous cavity haemorrhage in another were the only postoperative complications. OCT matched scans showed plug integration and inner retinal layers rearrangement. MH size did not correlate with final BCVA. Autofluorescence showed no developing atrophy signs during long-term follow-up.</p><p><strong>Conclusion: </strong>Cryopreserved human amniotic membrane transplant may be a valuable approach to achieve macular hole closure and visual acuity improvement in refractory MH.</p><p><strong>Key messages: </strong>What is known Human amniotic membrane transplantation is a recent surgical technique for refractory, chronic or extra-large macular holes. This surgical procedure has a shallow learning curve, high macular hole closure rate, does not require silicone oil tamponade and has very low complication rate. What is new Subretinal amniotic membrane transplant technique was successful at closing all patients' macular holes and improving visual acuity. Concerning final visual acuity predictors neither preoperative characteristics, namely the macular hole size or duration, etiology, lens status or axial length, nor surgical procedure modifications such as flap shape or tamponade lead to different outcomes. Our series included patients with refractory macular holes due to failed extended ILM peeling, failed inverted flap technique, failed autologous retinal transplant and failed epiretinal amniotic membrane transplant suggesting the technique's effectiveness in challenging refractory cases.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcomes of amniotic membrane transplant for refractory macular hole - an optical coherence tomography and autofluorescence long-term study.\",\"authors\":\"Helena Proença, Marília Antunes, Joana Tavares Ferreira, Paula Magro, Mun Faria, Carlos Marques-Neves\",\"doi\":\"10.1007/s00417-024-06609-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To analyze anatomical and functional outcomes of cryopreserved human amniotic membrane (hAM) transplant in refractory macular hole (MH) surgery, present retinal layers structure after MH closure, identify visual acuity improvement determinants and complication rate.</p><p><strong>Methods: </strong>Prospective and interventional case series including seventeen patients: 13 refractory and 4 chronic (8, 15, 18 and 30-years) MH. All patients underwent vitrectomy, hAM subretinal transplant, tamponade and positioning. Complete ophthalmological examination, axial length, best-corrected visual acuity, retinography, optical coherence tomography (OCT) and autofluorescence were recorded.</p><p><strong>Results: </strong>Mean follow-up was 31 months (range 6-53). Mean LogMAR visual acuity (1.71 ± 0.42) improved significantly (1.13 ± 0.41) (P < 0.001). Patients with better baseline BCVA ended up with better final BCVA (P = 0.018). Mean MH minimum linear diameter was 831 ± 252 μm and base diameter was 1409 ± 358 μm. MH closed in all patients. Transitory ocular hypertension in one patient and transient vitreous cavity haemorrhage in another were the only postoperative complications. OCT matched scans showed plug integration and inner retinal layers rearrangement. MH size did not correlate with final BCVA. Autofluorescence showed no developing atrophy signs during long-term follow-up.</p><p><strong>Conclusion: </strong>Cryopreserved human amniotic membrane transplant may be a valuable approach to achieve macular hole closure and visual acuity improvement in refractory MH.</p><p><strong>Key messages: </strong>What is known Human amniotic membrane transplantation is a recent surgical technique for refractory, chronic or extra-large macular holes. This surgical procedure has a shallow learning curve, high macular hole closure rate, does not require silicone oil tamponade and has very low complication rate. What is new Subretinal amniotic membrane transplant technique was successful at closing all patients' macular holes and improving visual acuity. Concerning final visual acuity predictors neither preoperative characteristics, namely the macular hole size or duration, etiology, lens status or axial length, nor surgical procedure modifications such as flap shape or tamponade lead to different outcomes. Our series included patients with refractory macular holes due to failed extended ILM peeling, failed inverted flap technique, failed autologous retinal transplant and failed epiretinal amniotic membrane transplant suggesting the technique's effectiveness in challenging refractory cases.</p>\",\"PeriodicalId\":12795,\"journal\":{\"name\":\"Graefe’s Archive for Clinical and Experimental Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Graefe’s Archive for Clinical and Experimental Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00417-024-06609-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-024-06609-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:分析低温保存的人羊膜(hAM)移植在难治性黄斑孔(MH)手术中的解剖和功能效果,呈现MH闭合后的视网膜层结构,确定视力改善的决定因素和并发症发生率:方法:前瞻性介入病例系列,包括 17 名患者:方法:前瞻性介入病例系列,包括 17 例患者:13 例难治性和 4 例慢性(8、15、18 和 30 年)MH。所有患者均接受了玻璃体切除术、hAM 视网膜下移植、填塞和定位。记录了完整的眼科检查、轴向长度、最佳矫正视力、视网膜造影、光学相干断层扫描(OCT)和自动荧光:平均随访时间为 31 个月(6-53 个月)。平均 LogMAR 视力(1.71±0.42)明显改善(1.13±0.41)(P. 结论):低温保存的人类羊膜移植可能是实现难治性 MH 黄斑孔闭合和视力改善的一种有价值的方法:已知信息:羊膜移植是一种治疗难治性、慢性或特大黄斑孔的最新手术技术。该手术学习曲线较浅,黄斑孔闭合率高,无需硅油填塞,并发症发生率极低。新进展 视网膜下羊膜移植技术成功关闭了所有患者的黄斑孔,并改善了视力。关于最终视力的预测因素,无论是术前特征,即黄斑孔大小或持续时间、病因、晶状体状态或轴向长度,还是手术方法的改变,如瓣的形状或填塞,都不会导致不同的结果。我们的系列研究包括了因延长ILM剥离失败、倒置瓣技术失败、自体视网膜移植失败和羊膜外视网膜移植失败而导致的难治性黄斑孔患者,这表明该技术在具有挑战性的难治性病例中是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Outcomes of amniotic membrane transplant for refractory macular hole - an optical coherence tomography and autofluorescence long-term study.

Purpose: To analyze anatomical and functional outcomes of cryopreserved human amniotic membrane (hAM) transplant in refractory macular hole (MH) surgery, present retinal layers structure after MH closure, identify visual acuity improvement determinants and complication rate.

Methods: Prospective and interventional case series including seventeen patients: 13 refractory and 4 chronic (8, 15, 18 and 30-years) MH. All patients underwent vitrectomy, hAM subretinal transplant, tamponade and positioning. Complete ophthalmological examination, axial length, best-corrected visual acuity, retinography, optical coherence tomography (OCT) and autofluorescence were recorded.

Results: Mean follow-up was 31 months (range 6-53). Mean LogMAR visual acuity (1.71 ± 0.42) improved significantly (1.13 ± 0.41) (P < 0.001). Patients with better baseline BCVA ended up with better final BCVA (P = 0.018). Mean MH minimum linear diameter was 831 ± 252 μm and base diameter was 1409 ± 358 μm. MH closed in all patients. Transitory ocular hypertension in one patient and transient vitreous cavity haemorrhage in another were the only postoperative complications. OCT matched scans showed plug integration and inner retinal layers rearrangement. MH size did not correlate with final BCVA. Autofluorescence showed no developing atrophy signs during long-term follow-up.

Conclusion: Cryopreserved human amniotic membrane transplant may be a valuable approach to achieve macular hole closure and visual acuity improvement in refractory MH.

Key messages: What is known Human amniotic membrane transplantation is a recent surgical technique for refractory, chronic or extra-large macular holes. This surgical procedure has a shallow learning curve, high macular hole closure rate, does not require silicone oil tamponade and has very low complication rate. What is new Subretinal amniotic membrane transplant technique was successful at closing all patients' macular holes and improving visual acuity. Concerning final visual acuity predictors neither preoperative characteristics, namely the macular hole size or duration, etiology, lens status or axial length, nor surgical procedure modifications such as flap shape or tamponade lead to different outcomes. Our series included patients with refractory macular holes due to failed extended ILM peeling, failed inverted flap technique, failed autologous retinal transplant and failed epiretinal amniotic membrane transplant suggesting the technique's effectiveness in challenging refractory cases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
398
审稿时长
3 months
期刊介绍: Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.
期刊最新文献
Clinical factors and predictors for spontaneous separation of epiretinal membranes. Preliminary antifibrotic and vasoconstrictor effects of adrenaline in Schlemm's canal and suprachoroidal minimally invasive glaucoma surgery in primary open-angle glaucoma. A cost-minimization analysis of anti-VEGFs for the treatment of neovascular age-related macular degeneration in the Netherlands. Comparison of visual quality after Q value-guided FS-LASIK and SMILE for correction of myopia with age-related accommodation deficiency. Evaluation of peripheral retinal degenerations using ultra-widefield swept source optical coherence tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1