{"title":"一个新的半关节成形术头和两个已成形的半关节成形术头的翻修率:来自瑞典关节成形术登记处的一项队列比较研究。","authors":"Cecilia Rogmark, Jonatan Nåtman, Sören Overgaard, Maziar Mohaddes","doi":"10.1177/11207000241282081","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The anatomical Lubinus SPII-stem is commonly used in hemi-arthroplasty for femoral neck fractures (FNF), combined with either the bipolar Variocup, the Unipolar Head (UH) and a newly introduced unipolar Modular Trauma Head (MTH). Similar constructs like the MTH are reported to have risk of corrosion and wear. This is the first publication evaluating the MTH.</p><p><strong>Aim: </strong>To describe the revision rate of the SPII-stems/heads which were divided into 3 groups (Variocup, UH, MTH). The head types are compared by their rate of revision at 2 years, due to any cause and to dislocation. Revision and mortality rates up to 10 years are reported.</p><p><strong>Methods: </strong>This observational cohort study based on prospectively registered data from the Swedish Arthroplasty Register included 33,059 patients with hemiarthroplasty 2005-2021 due to FNF. SPII-stems combined with Variocup (<i>n =</i> 7,281), UH (<i>n =</i> 23,980), MTH (<i>n =</i> 1,798) were included. The follow-up ended at 10 years for Variocup and UH, for MTH at 2 years. Kaplan-Meier survival analyses was used, with a 95% confidence interval (CI). Patients were censored at death or at the end of the study (31 December 2021).</p><p><strong>Results: </strong>The 2-year revision rate regardless of cause was similar between the groups: after Variocup 3.5% (CI, 3.1-4.0), UH 3.1% (CI, 2.9-3.4), MTH 3.5% (CI, 2.6-4.5).At 10 years, the Variocup and UH had similar revision rates; 4.6% (CI, 4.0-5.2) and 5.0% (CI, 4.4-5.6).For revision due to dislocation at 2 years Variocup 2.3% (CI, 1.9-2.7) had an inferior outcome compared to UH 1.5% (CI, 1.3-1.7). The MTH had an intermediate outcome, 1.7% (CI, 1.0-2.3). Variocup had a higher dislocation related revision rate, until the 10th year.The 2-year-mortality was 36% (CI, 35-37) after Variocup, 43% (CI, 42-43) after UH and 44% (CI, 41-47) after MTH.</p><p><strong>Conclusions: </strong>The hemi-heads have comparable revision rates within 2 and 10 years. The new MTH performs similar to the standard UH. The bipolar Variocup is associated with more revisions due to dislocation.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Revision rates of one new and two established hemiarthroplasty heads: a comparative cohort study from the Swedish Arthroplasty Register.\",\"authors\":\"Cecilia Rogmark, Jonatan Nåtman, Sören Overgaard, Maziar Mohaddes\",\"doi\":\"10.1177/11207000241282081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The anatomical Lubinus SPII-stem is commonly used in hemi-arthroplasty for femoral neck fractures (FNF), combined with either the bipolar Variocup, the Unipolar Head (UH) and a newly introduced unipolar Modular Trauma Head (MTH). Similar constructs like the MTH are reported to have risk of corrosion and wear. This is the first publication evaluating the MTH.</p><p><strong>Aim: </strong>To describe the revision rate of the SPII-stems/heads which were divided into 3 groups (Variocup, UH, MTH). The head types are compared by their rate of revision at 2 years, due to any cause and to dislocation. Revision and mortality rates up to 10 years are reported.</p><p><strong>Methods: </strong>This observational cohort study based on prospectively registered data from the Swedish Arthroplasty Register included 33,059 patients with hemiarthroplasty 2005-2021 due to FNF. SPII-stems combined with Variocup (<i>n =</i> 7,281), UH (<i>n =</i> 23,980), MTH (<i>n =</i> 1,798) were included. The follow-up ended at 10 years for Variocup and UH, for MTH at 2 years. Kaplan-Meier survival analyses was used, with a 95% confidence interval (CI). Patients were censored at death or at the end of the study (31 December 2021).</p><p><strong>Results: </strong>The 2-year revision rate regardless of cause was similar between the groups: after Variocup 3.5% (CI, 3.1-4.0), UH 3.1% (CI, 2.9-3.4), MTH 3.5% (CI, 2.6-4.5).At 10 years, the Variocup and UH had similar revision rates; 4.6% (CI, 4.0-5.2) and 5.0% (CI, 4.4-5.6).For revision due to dislocation at 2 years Variocup 2.3% (CI, 1.9-2.7) had an inferior outcome compared to UH 1.5% (CI, 1.3-1.7). The MTH had an intermediate outcome, 1.7% (CI, 1.0-2.3). Variocup had a higher dislocation related revision rate, until the 10th year.The 2-year-mortality was 36% (CI, 35-37) after Variocup, 43% (CI, 42-43) after UH and 44% (CI, 41-47) after MTH.</p><p><strong>Conclusions: </strong>The hemi-heads have comparable revision rates within 2 and 10 years. The new MTH performs similar to the standard UH. The bipolar Variocup is associated with more revisions due to dislocation.</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000241282081\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000241282081","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Revision rates of one new and two established hemiarthroplasty heads: a comparative cohort study from the Swedish Arthroplasty Register.
Introduction: The anatomical Lubinus SPII-stem is commonly used in hemi-arthroplasty for femoral neck fractures (FNF), combined with either the bipolar Variocup, the Unipolar Head (UH) and a newly introduced unipolar Modular Trauma Head (MTH). Similar constructs like the MTH are reported to have risk of corrosion and wear. This is the first publication evaluating the MTH.
Aim: To describe the revision rate of the SPII-stems/heads which were divided into 3 groups (Variocup, UH, MTH). The head types are compared by their rate of revision at 2 years, due to any cause and to dislocation. Revision and mortality rates up to 10 years are reported.
Methods: This observational cohort study based on prospectively registered data from the Swedish Arthroplasty Register included 33,059 patients with hemiarthroplasty 2005-2021 due to FNF. SPII-stems combined with Variocup (n = 7,281), UH (n = 23,980), MTH (n = 1,798) were included. The follow-up ended at 10 years for Variocup and UH, for MTH at 2 years. Kaplan-Meier survival analyses was used, with a 95% confidence interval (CI). Patients were censored at death or at the end of the study (31 December 2021).
Results: The 2-year revision rate regardless of cause was similar between the groups: after Variocup 3.5% (CI, 3.1-4.0), UH 3.1% (CI, 2.9-3.4), MTH 3.5% (CI, 2.6-4.5).At 10 years, the Variocup and UH had similar revision rates; 4.6% (CI, 4.0-5.2) and 5.0% (CI, 4.4-5.6).For revision due to dislocation at 2 years Variocup 2.3% (CI, 1.9-2.7) had an inferior outcome compared to UH 1.5% (CI, 1.3-1.7). The MTH had an intermediate outcome, 1.7% (CI, 1.0-2.3). Variocup had a higher dislocation related revision rate, until the 10th year.The 2-year-mortality was 36% (CI, 35-37) after Variocup, 43% (CI, 42-43) after UH and 44% (CI, 41-47) after MTH.
Conclusions: The hemi-heads have comparable revision rates within 2 and 10 years. The new MTH performs similar to the standard UH. The bipolar Variocup is associated with more revisions due to dislocation.
期刊介绍:
HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice.
The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit.
HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are:
• Biomaterials
• Biomechanics
• Conservative Hip Surgery
• Paediatrics
• Primary and Revision Hip Arthroplasty
• Traumatology