24 小时视频脑电图监测在诊断儿童癫痫中的实用性。

IF 1.7 Clinical EEG and neuroscience Pub Date : 2025-03-01 Epub Date: 2024-09-19 DOI:10.1177/15500594241286684
Qingxiang Zhang, Wenjin Zheng, Stéphane Jean, Fuliang Lai, Weihong Liu, Shiwei Song
{"title":"24 小时视频脑电图监测在诊断儿童癫痫中的实用性。","authors":"Qingxiang Zhang, Wenjin Zheng, Stéphane Jean, Fuliang Lai, Weihong Liu, Shiwei Song","doi":"10.1177/15500594241286684","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> Evaluate the diagnostic yield of 24-h video-EEG monitoring in a group of children admitted in our epilepsy monitoring unit (EMU). <b>Methods:</b> 232 children who underwent 24-h video-EEG monitoring was analysed. We divided each patient's monitoring duration into the first 1, 2, 4, 8, 16 h, relative to the whole 24 h monitoring period. The detection of the first interictal epileptiform discharges (IEDs), epileptic seizures (ES), and psychogenic non-epileptic seizures (PNES) were analysed relative to the different monitoring time subdivision. <b>Results:</b> Our findings revealed that: (1) there was no significant difference in the prevalence of detecting initial IEDs between the first 4-h and 24-h monitoring periods (73.7% vs 81%); (2) clinical events detection rate was statistically similar between the first 8-h and 24-h monitoring periods (15.5% vs 19.3%); (4) an 8-h monitoring was sufficient to capture IEDs, ES and PNES in focal epilepsy children; (5) a 1-h monitoring was sufficient to capture IEDs, ES and PNES in generalized epilepsy children; and (6) IEDs were detected within the first 1-h of monitoring in 96.7% self-limited focal epilepsies (SeLFEs) patient. <b>Conclusion:</b> Our study suggests that a 4-h monitoring has more value in increasing the detection rate of IEDs compared to the traditional shorter routine EEG. And in the case of SeLFEs, a 1-h of monitoring might be sufficient in detecting IEDs. A 24-h VEEG monitoring can detect clinical events in 19.3% of patients. Overall, the yield of IEDs and clinical events detection is adequate in children in children undergoing 24-h video-EEG monitoring.</p>","PeriodicalId":93940,"journal":{"name":"Clinical EEG and neuroscience","volume":" ","pages":"197-203"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Utility of 24-h Video-EEG Monitoring in the Diagnosis of Epilepsy in Children.\",\"authors\":\"Qingxiang Zhang, Wenjin Zheng, Stéphane Jean, Fuliang Lai, Weihong Liu, Shiwei Song\",\"doi\":\"10.1177/15500594241286684\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objectives:</b> Evaluate the diagnostic yield of 24-h video-EEG monitoring in a group of children admitted in our epilepsy monitoring unit (EMU). <b>Methods:</b> 232 children who underwent 24-h video-EEG monitoring was analysed. We divided each patient's monitoring duration into the first 1, 2, 4, 8, 16 h, relative to the whole 24 h monitoring period. The detection of the first interictal epileptiform discharges (IEDs), epileptic seizures (ES), and psychogenic non-epileptic seizures (PNES) were analysed relative to the different monitoring time subdivision. <b>Results:</b> Our findings revealed that: (1) there was no significant difference in the prevalence of detecting initial IEDs between the first 4-h and 24-h monitoring periods (73.7% vs 81%); (2) clinical events detection rate was statistically similar between the first 8-h and 24-h monitoring periods (15.5% vs 19.3%); (4) an 8-h monitoring was sufficient to capture IEDs, ES and PNES in focal epilepsy children; (5) a 1-h monitoring was sufficient to capture IEDs, ES and PNES in generalized epilepsy children; and (6) IEDs were detected within the first 1-h of monitoring in 96.7% self-limited focal epilepsies (SeLFEs) patient. <b>Conclusion:</b> Our study suggests that a 4-h monitoring has more value in increasing the detection rate of IEDs compared to the traditional shorter routine EEG. And in the case of SeLFEs, a 1-h of monitoring might be sufficient in detecting IEDs. A 24-h VEEG monitoring can detect clinical events in 19.3% of patients. Overall, the yield of IEDs and clinical events detection is adequate in children in children undergoing 24-h video-EEG monitoring.</p>\",\"PeriodicalId\":93940,\"journal\":{\"name\":\"Clinical EEG and neuroscience\",\"volume\":\" \",\"pages\":\"197-203\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical EEG and neuroscience\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15500594241286684\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical EEG and neuroscience","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15500594241286684","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/19 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估本院癫痫监测室(EMU)收治的一组儿童接受 24 小时视频脑电图监测的诊断率。方法:对接受 24 小时视频脑电图监测的 232 名儿童进行分析。我们将每位患者的监测时间分为最初的 1、2、4、8、16 小时,与整个 24 小时监测时间相对比。分析了不同监测时间段内首次发作间期癫痫样放电(IED)、癫痫发作(ES)和精神性非癫痫发作(PNES)的检测情况。结果显示我们的研究结果表明(1) 在最初的 4 小时和 24 小时监测期间,初始 IED 的检测率没有明显差异(73.7% vs 81%);(2) 在最初的 8 小时和 24 小时监测期间,临床事件的检测率在统计学上相似(15.5% vs 19.3%);(3) 在最初的 8 小时和 24 小时监测期间,临床事件的检测率没有明显差异(73.7% vs 81%)。3%);(4) 对局灶性癫痫儿童进行 8 h 监测足以捕获 IED、ES 和 PNES;(5) 对全身性癫痫儿童进行 1 h 监测足以捕获 IED、ES 和 PNES;(6) 96.7% 的自限性局灶性癫痫(SeLFEs)患者在监测的前 1 h 内检测到 IED。结论我们的研究表明,与传统的较短常规脑电图相比,4 小时监测对提高 IED 的检出率更有价值。而对于 SeLFEs,1 小时的监测可能就足以检测出 IED。24 小时 VEEG 监测可检测到 19.3% 患者的临床事件。总体而言,在接受 24 小时视频脑电图监测的儿童中,IED 和临床事件的检测率是足够的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Utility of 24-h Video-EEG Monitoring in the Diagnosis of Epilepsy in Children.

Objectives: Evaluate the diagnostic yield of 24-h video-EEG monitoring in a group of children admitted in our epilepsy monitoring unit (EMU). Methods: 232 children who underwent 24-h video-EEG monitoring was analysed. We divided each patient's monitoring duration into the first 1, 2, 4, 8, 16 h, relative to the whole 24 h monitoring period. The detection of the first interictal epileptiform discharges (IEDs), epileptic seizures (ES), and psychogenic non-epileptic seizures (PNES) were analysed relative to the different monitoring time subdivision. Results: Our findings revealed that: (1) there was no significant difference in the prevalence of detecting initial IEDs between the first 4-h and 24-h monitoring periods (73.7% vs 81%); (2) clinical events detection rate was statistically similar between the first 8-h and 24-h monitoring periods (15.5% vs 19.3%); (4) an 8-h monitoring was sufficient to capture IEDs, ES and PNES in focal epilepsy children; (5) a 1-h monitoring was sufficient to capture IEDs, ES and PNES in generalized epilepsy children; and (6) IEDs were detected within the first 1-h of monitoring in 96.7% self-limited focal epilepsies (SeLFEs) patient. Conclusion: Our study suggests that a 4-h monitoring has more value in increasing the detection rate of IEDs compared to the traditional shorter routine EEG. And in the case of SeLFEs, a 1-h of monitoring might be sufficient in detecting IEDs. A 24-h VEEG monitoring can detect clinical events in 19.3% of patients. Overall, the yield of IEDs and clinical events detection is adequate in children in children undergoing 24-h video-EEG monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prefrontal and Occipital Network Excitability Differences in Dementia with Lewy Bodies and Alzheimer's Disease. The Effects of Abstinence status and Sleep Quality on Resting State Alpha Power in Cocaine Use Disorder. Development of a Human Electrophysiology Laboratory to Advance Cognitive Neuroscience in Western Kenya. BiLSTM-Based Human Emotion Classification Using EEG Signal. Reappraisal of Palinopsia as a Disregarded Symptom in Epilepsy: A Case Report and Systematic Review of the Related EEG Findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1