{"title":"在中国 2 型糖尿病患者中验证通用版中国健康相关结果测量(CHROME-G)。","authors":"Meixuan Li, Shitong Xie, Minyan Yang, Yanan Wu, Zijun Li, Rui Li, Xiuxia Li, Xue Li, Yijun Liu, Jing Wu, Kun Zhao, Feng Xie, Kehu Yang","doi":"10.1111/jebm.12642","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>The Generic Version of China Health Related Outcomes Measures (CHROME-G) was a new preference-based health-related quality of life (HRQoL) instrument designed specifically for the Chinese population. This study aimed to validate and compare measurement properties of CHROME-G with EuroQol-5 Dimensions-5 Levels (EQ-5D-5L), Short Form-6 Dimensions version 2 (SF-6Dv2), and Diabetes-Specific Quality of Life (DSQL) scales among the elderly Chinese population with type 2 diabetes.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A representative sample population was recruited across the country. Internal consistency was assessed using Cronbach's alpha. Hypotheses testing including convergent validity and known-groups validity were evaluated using Spearman's rank correlation and effect sizes, respectively. Sensitivity was examined using relative efficiency and receiver operating characteristic curve.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>A total of 131 individuals with type 2 diabetes (54.20% male; mean age 69.03 years) were enrolled. Cronbach's alpha was 0.94 for DSQL, 0.93 for CHROME-G, 0.87 for EQ-5D-5L, and 0.88 for SF-6Dv2. For the convergent validity of CHROME-G, 24/29 (82.76%) correlations met the predefined hypotheses, with Spearman's rank correlation coefficients ranging from 0.51 to 0.96. Among the different health subgroups, the effect sizes for CHROME-G, DSQL, EQ-5D-5L, and SF-6Dv2 were 0.19–1.26, 0.36–1.62, 0.22–1.06, and 0.49–0.87, respectively. CHROME-G, DSQL, and SF-6Dv2 had higher efficiency compared with EQ-5D-5L in detecting differences in self-reported health status, with relative efficiency of 3.18 and 1.76, 4.38 and 6.52, and 1.56 and 2.09, respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>CHROME-G demonstrates relatively good measurement properties compared with EQ-5D-5L and SF-6Dv2 for measuring the HRQoL among the elderly Chinese population with type 2 diabetes. The sensitivity of DSQL appears to be better than that of the three generic instruments.</p>\n </section>\n </div>","PeriodicalId":16090,"journal":{"name":"Journal of Evidence‐Based Medicine","volume":"17 3","pages":"615-625"},"PeriodicalIF":3.6000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of the Generic Version of China Health Related Outcomes Measures (CHROME-G) among individuals with type 2 diabetes in China\",\"authors\":\"Meixuan Li, Shitong Xie, Minyan Yang, Yanan Wu, Zijun Li, Rui Li, Xiuxia Li, Xue Li, Yijun Liu, Jing Wu, Kun Zhao, Feng Xie, Kehu Yang\",\"doi\":\"10.1111/jebm.12642\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>The Generic Version of China Health Related Outcomes Measures (CHROME-G) was a new preference-based health-related quality of life (HRQoL) instrument designed specifically for the Chinese population. This study aimed to validate and compare measurement properties of CHROME-G with EuroQol-5 Dimensions-5 Levels (EQ-5D-5L), Short Form-6 Dimensions version 2 (SF-6Dv2), and Diabetes-Specific Quality of Life (DSQL) scales among the elderly Chinese population with type 2 diabetes.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A representative sample population was recruited across the country. Internal consistency was assessed using Cronbach's alpha. Hypotheses testing including convergent validity and known-groups validity were evaluated using Spearman's rank correlation and effect sizes, respectively. Sensitivity was examined using relative efficiency and receiver operating characteristic curve.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>A total of 131 individuals with type 2 diabetes (54.20% male; mean age 69.03 years) were enrolled. Cronbach's alpha was 0.94 for DSQL, 0.93 for CHROME-G, 0.87 for EQ-5D-5L, and 0.88 for SF-6Dv2. For the convergent validity of CHROME-G, 24/29 (82.76%) correlations met the predefined hypotheses, with Spearman's rank correlation coefficients ranging from 0.51 to 0.96. Among the different health subgroups, the effect sizes for CHROME-G, DSQL, EQ-5D-5L, and SF-6Dv2 were 0.19–1.26, 0.36–1.62, 0.22–1.06, and 0.49–0.87, respectively. CHROME-G, DSQL, and SF-6Dv2 had higher efficiency compared with EQ-5D-5L in detecting differences in self-reported health status, with relative efficiency of 3.18 and 1.76, 4.38 and 6.52, and 1.56 and 2.09, respectively.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>CHROME-G demonstrates relatively good measurement properties compared with EQ-5D-5L and SF-6Dv2 for measuring the HRQoL among the elderly Chinese population with type 2 diabetes. The sensitivity of DSQL appears to be better than that of the three generic instruments.</p>\\n </section>\\n </div>\",\"PeriodicalId\":16090,\"journal\":{\"name\":\"Journal of Evidence‐Based Medicine\",\"volume\":\"17 3\",\"pages\":\"615-625\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Evidence‐Based Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jebm.12642\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Evidence‐Based Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jebm.12642","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Validation of the Generic Version of China Health Related Outcomes Measures (CHROME-G) among individuals with type 2 diabetes in China
Objective
The Generic Version of China Health Related Outcomes Measures (CHROME-G) was a new preference-based health-related quality of life (HRQoL) instrument designed specifically for the Chinese population. This study aimed to validate and compare measurement properties of CHROME-G with EuroQol-5 Dimensions-5 Levels (EQ-5D-5L), Short Form-6 Dimensions version 2 (SF-6Dv2), and Diabetes-Specific Quality of Life (DSQL) scales among the elderly Chinese population with type 2 diabetes.
Methods
A representative sample population was recruited across the country. Internal consistency was assessed using Cronbach's alpha. Hypotheses testing including convergent validity and known-groups validity were evaluated using Spearman's rank correlation and effect sizes, respectively. Sensitivity was examined using relative efficiency and receiver operating characteristic curve.
Results
A total of 131 individuals with type 2 diabetes (54.20% male; mean age 69.03 years) were enrolled. Cronbach's alpha was 0.94 for DSQL, 0.93 for CHROME-G, 0.87 for EQ-5D-5L, and 0.88 for SF-6Dv2. For the convergent validity of CHROME-G, 24/29 (82.76%) correlations met the predefined hypotheses, with Spearman's rank correlation coefficients ranging from 0.51 to 0.96. Among the different health subgroups, the effect sizes for CHROME-G, DSQL, EQ-5D-5L, and SF-6Dv2 were 0.19–1.26, 0.36–1.62, 0.22–1.06, and 0.49–0.87, respectively. CHROME-G, DSQL, and SF-6Dv2 had higher efficiency compared with EQ-5D-5L in detecting differences in self-reported health status, with relative efficiency of 3.18 and 1.76, 4.38 and 6.52, and 1.56 and 2.09, respectively.
Conclusions
CHROME-G demonstrates relatively good measurement properties compared with EQ-5D-5L and SF-6Dv2 for measuring the HRQoL among the elderly Chinese population with type 2 diabetes. The sensitivity of DSQL appears to be better than that of the three generic instruments.
期刊介绍:
The Journal of Evidence-Based Medicine (EMB) is an esteemed international healthcare and medical decision-making journal, dedicated to publishing groundbreaking research outcomes in evidence-based decision-making, research, practice, and education. Serving as the official English-language journal of the Cochrane China Centre and West China Hospital of Sichuan University, we eagerly welcome editorials, commentaries, and systematic reviews encompassing various topics such as clinical trials, policy, drug and patient safety, education, and knowledge translation.