用于小动物模型中单肺应用的低容量原位肺灌注系统可最佳遵守动物研究 3R 原则中的 "减少 "原则。

IF 2.7 3区 医学 Q1 SURGERY Transplant International Pub Date : 2024-09-09 eCollection Date: 2024-01-01 DOI:10.3389/ti.2024.13189
K Katsirntaki, S Hagner, C Werlein, P Braubach, D Jonigk, D Adam, H Hidaji, C Kühn, C S Falk, A Ruhparwar, B Wiegmann
{"title":"用于小动物模型中单肺应用的低容量原位肺灌注系统可最佳遵守动物研究 3R 原则中的 \"减少 \"原则。","authors":"K Katsirntaki, S Hagner, C Werlein, P Braubach, D Jonigk, D Adam, H Hidaji, C Kühn, C S Falk, A Ruhparwar, B Wiegmann","doi":"10.3389/ti.2024.13189","DOIUrl":null,"url":null,"abstract":"<p><p><i>Ex situ</i> lung perfusion (ESLP) is used for organ reconditioning, repair, and re-evaluation prior to transplantation. Since valid preclinical animal models are required for translationally relevant studies, we developed a 17 mL low-volume ESLP for double- and single-lung application that enables cost-effective optimal compliance \"reduction\" of the 3R principles of animal research. In single-lung mode, ten Fischer344 and Lewis rat lungs were subjected to ESLP and static cold storage using STEEN or PerfadexPlus. Key perfusion parameters, thermal lung imaging, blood gas analysis (BGA), colloid oncotic pressure (COP), lung weight gain, histological work-up, and cytokine analysis were performed. Significant differences between perfusion solutions but not between the rat strains were detected. Most relevant perfusion parameters confirmed valid ESLP with homogeneous lung perfusion, evidenced by uniform lung surface temperature. BGA showed temperature-dependent metabolic activities with differences depending on perfusion solution composition. COP is not decisive for pulmonary oedema and associated weight gain, but possibly rather observed chemokine profile and dextran sensitivity of rats. Histological examination confirmed intact lung architecture without infarcts or hemorrhages due to optimal organ procurement and single-lung application protocol using our in-house-designed ESLP system.</p>","PeriodicalId":23343,"journal":{"name":"Transplant International","volume":"37 ","pages":"13189"},"PeriodicalIF":2.7000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11418019/pdf/","citationCount":"0","resultStr":"{\"title\":\"Low-Volume <i>Ex Situ</i> Lung Perfusion System for Single Lung Application in a Small Animal Model Enables Optimal Compliance With \\\"<i>Reduction</i>\\\" in 3R Principles of Animal Research.\",\"authors\":\"K Katsirntaki, S Hagner, C Werlein, P Braubach, D Jonigk, D Adam, H Hidaji, C Kühn, C S Falk, A Ruhparwar, B Wiegmann\",\"doi\":\"10.3389/ti.2024.13189\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Ex situ</i> lung perfusion (ESLP) is used for organ reconditioning, repair, and re-evaluation prior to transplantation. Since valid preclinical animal models are required for translationally relevant studies, we developed a 17 mL low-volume ESLP for double- and single-lung application that enables cost-effective optimal compliance \\\"reduction\\\" of the 3R principles of animal research. In single-lung mode, ten Fischer344 and Lewis rat lungs were subjected to ESLP and static cold storage using STEEN or PerfadexPlus. Key perfusion parameters, thermal lung imaging, blood gas analysis (BGA), colloid oncotic pressure (COP), lung weight gain, histological work-up, and cytokine analysis were performed. Significant differences between perfusion solutions but not between the rat strains were detected. Most relevant perfusion parameters confirmed valid ESLP with homogeneous lung perfusion, evidenced by uniform lung surface temperature. BGA showed temperature-dependent metabolic activities with differences depending on perfusion solution composition. COP is not decisive for pulmonary oedema and associated weight gain, but possibly rather observed chemokine profile and dextran sensitivity of rats. Histological examination confirmed intact lung architecture without infarcts or hemorrhages due to optimal organ procurement and single-lung application protocol using our in-house-designed ESLP system.</p>\",\"PeriodicalId\":23343,\"journal\":{\"name\":\"Transplant International\",\"volume\":\"37 \",\"pages\":\"13189\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11418019/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transplant International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3389/ti.2024.13189\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transplant International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/ti.2024.13189","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

原位肺灌注(ESLP)用于移植前的器官调理、修复和重新评估。由于转化相关研究需要有效的临床前动物模型,我们开发了一种用于双肺和单肺的 17 mL 低容量 ESLP,可实现符合动物研究 3R 原则的成本效益最佳 "还原"。在单肺模式下,使用 STEEN 或 PerfadexPlus 对 10 只 Fischer344 和 Lewis 大鼠肺进行 ESLP 和静态冷藏。对关键灌注参数、肺热成像、血气分析 (BGA)、胶体渗透压 (COP)、肺增重、组织学检查和细胞因子分析进行了研究。结果表明,不同灌注溶液之间存在显著差异,但大鼠品系之间没有差异。大多数相关灌注参数证实 ESLP 有效,肺灌注均匀,肺表面温度一致。BGA显示出与温度相关的代谢活动,其差异取决于灌注溶液的成分。COP对肺水肿和相关的体重增加并不具有决定性作用,而可能是观察到的趋化因子特征和大鼠对右旋糖酐的敏感性。组织学检查证实肺部结构完好无损,没有梗塞或出血,这得益于使用我们自行设计的 ESLP 系统进行的最佳器官采购和单肺应用方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Low-Volume Ex Situ Lung Perfusion System for Single Lung Application in a Small Animal Model Enables Optimal Compliance With "Reduction" in 3R Principles of Animal Research.

Ex situ lung perfusion (ESLP) is used for organ reconditioning, repair, and re-evaluation prior to transplantation. Since valid preclinical animal models are required for translationally relevant studies, we developed a 17 mL low-volume ESLP for double- and single-lung application that enables cost-effective optimal compliance "reduction" of the 3R principles of animal research. In single-lung mode, ten Fischer344 and Lewis rat lungs were subjected to ESLP and static cold storage using STEEN or PerfadexPlus. Key perfusion parameters, thermal lung imaging, blood gas analysis (BGA), colloid oncotic pressure (COP), lung weight gain, histological work-up, and cytokine analysis were performed. Significant differences between perfusion solutions but not between the rat strains were detected. Most relevant perfusion parameters confirmed valid ESLP with homogeneous lung perfusion, evidenced by uniform lung surface temperature. BGA showed temperature-dependent metabolic activities with differences depending on perfusion solution composition. COP is not decisive for pulmonary oedema and associated weight gain, but possibly rather observed chemokine profile and dextran sensitivity of rats. Histological examination confirmed intact lung architecture without infarcts or hemorrhages due to optimal organ procurement and single-lung application protocol using our in-house-designed ESLP system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Transplant International
Transplant International 医学-外科
CiteScore
4.70
自引率
6.50%
发文量
211
审稿时长
3-8 weeks
期刊介绍: The aim of the journal is to serve as a forum for the exchange of scientific information in the form of original and high quality papers in the field of transplantation. Clinical and experimental studies, as well as editorials, letters to the editors, and, occasionally, reviews on the biology, physiology, and immunology of transplantation of tissues and organs, are published. Publishing time for the latter is approximately six months, provided major revisions are not needed. The journal is published in yearly volumes, each volume containing twelve issues. Papers submitted to the journal are subject to peer review.
期刊最新文献
Normothermic Machine Perfusion Reconstitutes Porcine Kidney Tissue Metabolism But Induces an Inflammatory Response, Which Is Reduced by Complement C5 Inhibition. Angiotensin II Type-1 Receptor Antibody in Solid Organ Transplantation - Is It Time to Test? Allorecognition Unveiled: Integrating Recent Breakthroughs Into the Current Paradigm. The impact of the EVLP on the lung microbiome and its inflammatory reaction. Adjusted Donor Age: A Clinical Score to Support Organ Acceptance Decisions in Deceased-Donor Kidney Transplantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1