{"title":"在人工耳蜗声音处理器上安装耳机,取代直接音频输入。","authors":"Joshua G W Bernstein, Julianna Voelker, Sandeep A Phatak","doi":"10.1121/10.0028737","DOIUrl":null,"url":null,"abstract":"<p><p>Psychoacoustic stimulus presentation to the cochlear implant via direct audio input (DAI) is no longer possible for many newer sound processors (SPs). This study assessed the feasibility of placing circumaural headphones over the SP. Calibration spectra for loudspeaker, DAI, and headphone modalities were estimated by measuring cochlear-implant electrical output levels for tones presented to SPs on an acoustic manikin. Differences in calibration spectra between modalities arose mainly from microphone-response characteristics (high-frequency differences between DAI and the other modalities) or a proximity effect (low-frequency differences between headphones and loudspeaker). Calibration tables are provided to adjust for differences between the three modalities.</p>","PeriodicalId":73538,"journal":{"name":"JASA express letters","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Headphones over the cochlear-implant sound processor to replace direct audio input.\",\"authors\":\"Joshua G W Bernstein, Julianna Voelker, Sandeep A Phatak\",\"doi\":\"10.1121/10.0028737\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Psychoacoustic stimulus presentation to the cochlear implant via direct audio input (DAI) is no longer possible for many newer sound processors (SPs). This study assessed the feasibility of placing circumaural headphones over the SP. Calibration spectra for loudspeaker, DAI, and headphone modalities were estimated by measuring cochlear-implant electrical output levels for tones presented to SPs on an acoustic manikin. Differences in calibration spectra between modalities arose mainly from microphone-response characteristics (high-frequency differences between DAI and the other modalities) or a proximity effect (low-frequency differences between headphones and loudspeaker). Calibration tables are provided to adjust for differences between the three modalities.</p>\",\"PeriodicalId\":73538,\"journal\":{\"name\":\"JASA express letters\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JASA express letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1121/10.0028737\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JASA express letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1121/10.0028737","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

对于许多较新的声音处理器(SP)来说,通过直接音频输入(DAI)向人工耳蜗提供心理声学刺激已不再可能。本研究评估了在 SP 上放置环耳耳机的可行性。通过测量在声学人体模型上向 SP 播放音调时人工耳蜗的电输出水平,估算了扬声器、DAI 和耳机模式的校准频谱。不同模式之间校准频谱的差异主要来自麦克风响应特性(DAI 和其他模式之间的高频差异)或邻近效应(耳机和扬声器之间的低频差异)。我们提供了校准表来调整三种模式之间的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Headphones over the cochlear-implant sound processor to replace direct audio input.

Psychoacoustic stimulus presentation to the cochlear implant via direct audio input (DAI) is no longer possible for many newer sound processors (SPs). This study assessed the feasibility of placing circumaural headphones over the SP. Calibration spectra for loudspeaker, DAI, and headphone modalities were estimated by measuring cochlear-implant electrical output levels for tones presented to SPs on an acoustic manikin. Differences in calibration spectra between modalities arose mainly from microphone-response characteristics (high-frequency differences between DAI and the other modalities) or a proximity effect (low-frequency differences between headphones and loudspeaker). Calibration tables are provided to adjust for differences between the three modalities.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
期刊最新文献
Effect of hearing aids on the externalization of everyday sounds. Tests of human auditory temporal resolution: Simulations of Bayesian threshold estimation for auditory gap detection. Hearing aid evaluation for music: Accounting for acoustical variability of music stimuli. Minima in cubic distortion-product otoacoustic emission input/output functions due to distributed primary sources. Investigating muscle coordination patterns with Granger causality analysis in protrusive motion from tagged and diffusion MRI.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1