Runxin Fang , Zidun Wang , Jiaqiu Wang , Jiayu Gu , Geman Yin , Qiang Chen , Xunrong Xia , Zhiyong Li
{"title":"心房颤动患者肺静脉血流特征及其对左心房阑尾血栓形成的影响","authors":"Runxin Fang , Zidun Wang , Jiaqiu Wang , Jiayu Gu , Geman Yin , Qiang Chen , Xunrong Xia , Zhiyong Li","doi":"10.1016/j.cmpb.2024.108428","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Cardioembolic strokes are commonly occurred in non-valvular atrial fibrillation (AF) patients, with over 90% of cases originating from clot in left atrial appendage (LAA), which is believed to be greatly related with hemodynamic characters. Numerical simulation is widely accepted in the hemodynamic analysis, and patient-specific boundaries are required for realistic numerical simulations.</div></div><div><h3>Method</h3><div>This paper firstly proposed a method that maps personalized pulmonary venous flow (PVF) by utilizing the volume changes of the left atrium (LA) over the cardiac cycle. Then we used data from patients with AF to investigate the correlation between PVF patterns and hemodynamics within the LAA. Meanwhile, we conducted a fluid-structure interaction analysis to assess the impact of velocity- and time-related PVF parameters on LAA hemodynamic characters.</div></div><div><h3>Results</h3><div>The analysis reveal that the ratio of systolic to diastolic peak velocity (<em>V</em><sub>S</sub>/<em>V</em><sub>D</sub>), and systolic velocity-time integral (VTI) showed a significant influence on LAA velocity in patients with atrial fibrillation, and the increases of velocity- and time-related parameters were found to be positively correlated with the blood update in the LAA.</div></div><div><h3>Conclusions</h3><div>This study established a method for mapping patient-specific PVF based on LA volume change, and evaluated the relationship between PVF parameters and thrombosis risk. The present work provides an insight from PVF characters to evaluate the risk of thrombus formation within LAA in patients with AF.</div></div>","PeriodicalId":10624,"journal":{"name":"Computer methods and programs in biomedicine","volume":"257 ","pages":"Article 108428"},"PeriodicalIF":4.9000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Patient-specific pulmonary venous flow characterization and its impact on left atrial appendage thrombosis in atrial fibrillation patients\",\"authors\":\"Runxin Fang , Zidun Wang , Jiaqiu Wang , Jiayu Gu , Geman Yin , Qiang Chen , Xunrong Xia , Zhiyong Li\",\"doi\":\"10.1016/j.cmpb.2024.108428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Cardioembolic strokes are commonly occurred in non-valvular atrial fibrillation (AF) patients, with over 90% of cases originating from clot in left atrial appendage (LAA), which is believed to be greatly related with hemodynamic characters. Numerical simulation is widely accepted in the hemodynamic analysis, and patient-specific boundaries are required for realistic numerical simulations.</div></div><div><h3>Method</h3><div>This paper firstly proposed a method that maps personalized pulmonary venous flow (PVF) by utilizing the volume changes of the left atrium (LA) over the cardiac cycle. Then we used data from patients with AF to investigate the correlation between PVF patterns and hemodynamics within the LAA. Meanwhile, we conducted a fluid-structure interaction analysis to assess the impact of velocity- and time-related PVF parameters on LAA hemodynamic characters.</div></div><div><h3>Results</h3><div>The analysis reveal that the ratio of systolic to diastolic peak velocity (<em>V</em><sub>S</sub>/<em>V</em><sub>D</sub>), and systolic velocity-time integral (VTI) showed a significant influence on LAA velocity in patients with atrial fibrillation, and the increases of velocity- and time-related parameters were found to be positively correlated with the blood update in the LAA.</div></div><div><h3>Conclusions</h3><div>This study established a method for mapping patient-specific PVF based on LA volume change, and evaluated the relationship between PVF parameters and thrombosis risk. The present work provides an insight from PVF characters to evaluate the risk of thrombus formation within LAA in patients with AF.</div></div>\",\"PeriodicalId\":10624,\"journal\":{\"name\":\"Computer methods and programs in biomedicine\",\"volume\":\"257 \",\"pages\":\"Article 108428\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer methods and programs in biomedicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0169260724004218\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer methods and programs in biomedicine","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0169260724004218","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
Patient-specific pulmonary venous flow characterization and its impact on left atrial appendage thrombosis in atrial fibrillation patients
Background
Cardioembolic strokes are commonly occurred in non-valvular atrial fibrillation (AF) patients, with over 90% of cases originating from clot in left atrial appendage (LAA), which is believed to be greatly related with hemodynamic characters. Numerical simulation is widely accepted in the hemodynamic analysis, and patient-specific boundaries are required for realistic numerical simulations.
Method
This paper firstly proposed a method that maps personalized pulmonary venous flow (PVF) by utilizing the volume changes of the left atrium (LA) over the cardiac cycle. Then we used data from patients with AF to investigate the correlation between PVF patterns and hemodynamics within the LAA. Meanwhile, we conducted a fluid-structure interaction analysis to assess the impact of velocity- and time-related PVF parameters on LAA hemodynamic characters.
Results
The analysis reveal that the ratio of systolic to diastolic peak velocity (VS/VD), and systolic velocity-time integral (VTI) showed a significant influence on LAA velocity in patients with atrial fibrillation, and the increases of velocity- and time-related parameters were found to be positively correlated with the blood update in the LAA.
Conclusions
This study established a method for mapping patient-specific PVF based on LA volume change, and evaluated the relationship between PVF parameters and thrombosis risk. The present work provides an insight from PVF characters to evaluate the risk of thrombus formation within LAA in patients with AF.
期刊介绍:
To encourage the development of formal computing methods, and their application in biomedical research and medical practice, by illustration of fundamental principles in biomedical informatics research; to stimulate basic research into application software design; to report the state of research of biomedical information processing projects; to report new computer methodologies applied in biomedical areas; the eventual distribution of demonstrable software to avoid duplication of effort; to provide a forum for discussion and improvement of existing software; to optimize contact between national organizations and regional user groups by promoting an international exchange of information on formal methods, standards and software in biomedicine.
Computer Methods and Programs in Biomedicine covers computing methodology and software systems derived from computing science for implementation in all aspects of biomedical research and medical practice. It is designed to serve: biochemists; biologists; geneticists; immunologists; neuroscientists; pharmacologists; toxicologists; clinicians; epidemiologists; psychiatrists; psychologists; cardiologists; chemists; (radio)physicists; computer scientists; programmers and systems analysts; biomedical, clinical, electrical and other engineers; teachers of medical informatics and users of educational software.