通过动态放射性立体测量分析评估桡骨头关节置换术延长后的肘关节运动学。

IF 4.9 1区 医学 Q1 ORTHOPEDICS Bone & Joint Journal Pub Date : 2024-10-01 DOI:10.1302/0301-620X.106B10.BJJ-2024-0405.R1
Johanne Frost Teilmann, Emil T Petersen, Theis M Thillemann, Chalotte K Hemmingsen, Josephine Olsen Kipp, Thomas Falstie-Jensen, Maiken Stilling
{"title":"通过动态放射性立体测量分析评估桡骨头关节置换术延长后的肘关节运动学。","authors":"Johanne Frost Teilmann, Emil T Petersen, Theis M Thillemann, Chalotte K Hemmingsen, Josephine Olsen Kipp, Thomas Falstie-Jensen, Maiken Stilling","doi":"10.1302/0301-620X.106B10.BJJ-2024-0405.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).</p><p><strong>Methods: </strong>Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.</p><p><strong>Results: </strong>The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.</p><p><strong>Conclusion: </strong>The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.</p>","PeriodicalId":48944,"journal":{"name":"Bone & Joint Journal","volume":"106-B 10","pages":"1165-1175"},"PeriodicalIF":4.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Elbow kinematics with increased lengthening of a radial head arthroplasty evaluated with dynamic radiostereometric analysis.\",\"authors\":\"Johanne Frost Teilmann, Emil T Petersen, Theis M Thillemann, Chalotte K Hemmingsen, Josephine Olsen Kipp, Thomas Falstie-Jensen, Maiken Stilling\",\"doi\":\"10.1302/0301-620X.106B10.BJJ-2024-0405.R1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).</p><p><strong>Methods: </strong>Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.</p><p><strong>Results: </strong>The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.</p><p><strong>Conclusion: </strong>The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.</p>\",\"PeriodicalId\":48944,\"journal\":{\"name\":\"Bone & Joint Journal\",\"volume\":\"106-B 10\",\"pages\":\"1165-1175\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bone & Joint Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1302/0301-620X.106B10.BJJ-2024-0405.R1\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/0301-620X.106B10.BJJ-2024-0405.R1","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在使用动态放射立体测量法(dRSA)评估桡骨长度增加后肘关节的运动学特性:方法:在前臂处于无负荷中立位时,通过运动控制肘关节的屈伸,以及在分别施加和不施加 10 N 的外翻或内翻负荷的情况下,使用动态放射立体定向测量法(dRSA)对 8 只供体手臂进行了检查。肘部在RHA前后分别进行了检查,肘杆长度分别为解剖尺寸、+ 2毫米和+ 4毫米。通过阶梯式肱骨外上髁外侧截骨术保持了韧带的完整性,从而可以反复更换 RHA。通过 CT 扫描获得骨骼模型,并使用专用软件将这些模型与 dRSA 记录相匹配。使用解剖坐标系描述了肘关节的屈曲运动学,以定义具有六个自由度的平移和旋转:结果:肘关节运动学变化最大的是最长的 + 4 毫米植入物,该植入物在肱骨外侧关节和尺桡关节分别造成了 2.8 毫米和 1.1 毫米的平均关节牵张,桡骨和尺骨的平均变位角度都增加了 2.4°,桡骨在尺骨方向的平均移位为 2.0 毫米,尺骨向后方的平均移位为 1.0 毫米:结论:当桡骨延长 2 毫米至 4 毫米时,肘关节的运动学特性与原生关节的运动学特性之间的偏差越来越大。这证实了在进行RHA时恢复桡骨自然长度的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Elbow kinematics with increased lengthening of a radial head arthroplasty evaluated with dynamic radiostereometric analysis.

Aims: The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).

Methods: Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.

Results: The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.

Conclusion: The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bone & Joint Journal
Bone & Joint Journal ORTHOPEDICS-SURGERY
CiteScore
9.40
自引率
10.90%
发文量
318
期刊介绍: We welcome original articles from any part of the world. The papers are assessed by members of the Editorial Board and our international panel of expert reviewers, then either accepted for publication or rejected by the Editor. We receive over 2000 submissions each year and accept about 250 for publication, many after revisions recommended by the reviewers, editors or statistical advisers. A decision usually takes between six and eight weeks. Each paper is assessed by two reviewers with a special interest in the subject covered by the paper, and also by members of the editorial team. Controversial papers will be discussed at a full meeting of the Editorial Board. Publication is between four and six months after acceptance.
期刊最新文献
Contemporary insights into spinopelvic mechanics. Core Outcome Domains for Elbow Replacement (CODER). Defining multilevel developmental cervical spinal stenosis using MRI. Delayed fixation of distal radial fractures beyond three weeks after initial failed closed reduction increases the odds of reoperation. Detection, classification, and characterization of proximal humerus fractures on plain radiographs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1