{"title":"VirClia IgM/IgG 化学发光检验用于挪威蜱传脑炎流行地区诊断的临床评估。","authors":"Åshild Marvik, Susanne Gjeruldsen Dudman","doi":"10.3390/v16091505","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the clinical usefulness of VirClia IgM/IgG single-assay chemiluminescence tests for the diagnosis of tick-borne encephalitis (TBE) in an endemic part of Norway. Patients hospitalized at Vestfold or Telemark Hospitals with suspected infection in the central nervous system (CNS) in the period between May 2021 and December 2023 were included, with 85 TBE cases identified. The VirClia IgM assay was positive in the initial serum sample in 75/85 cases, giving a sensitivity of 88.2% (95% CI, 79.4-94.2). The ReaScan TBE IgM rapid test was positive in 80/85 cases, with an estimated sensitivity of 94.1% (95% CI, 86.8-98.1). Vaccine breakthrough infections were the predominant cause of non-reactive IgM cases. The calculated specificity for the VirClia IgM was 95.8% (95% CI, 92.5-98.0). In conclusion, the sensitivity of the VirClia IgM was non-inferior to the ReaScan TBE IgM rapid test. However, isolated IgM reactive results must be interpreted with caution, since false-reactive results occur.</p>","PeriodicalId":49328,"journal":{"name":"Viruses-Basel","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11437423/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical Evaluation of the VirClia IgM/IgG Chemiluminescence Tests for the Diagnosis of Tick-Borne Encephalitis in an Endemic Part of Norway.\",\"authors\":\"Åshild Marvik, Susanne Gjeruldsen Dudman\",\"doi\":\"10.3390/v16091505\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to evaluate the clinical usefulness of VirClia IgM/IgG single-assay chemiluminescence tests for the diagnosis of tick-borne encephalitis (TBE) in an endemic part of Norway. Patients hospitalized at Vestfold or Telemark Hospitals with suspected infection in the central nervous system (CNS) in the period between May 2021 and December 2023 were included, with 85 TBE cases identified. The VirClia IgM assay was positive in the initial serum sample in 75/85 cases, giving a sensitivity of 88.2% (95% CI, 79.4-94.2). The ReaScan TBE IgM rapid test was positive in 80/85 cases, with an estimated sensitivity of 94.1% (95% CI, 86.8-98.1). Vaccine breakthrough infections were the predominant cause of non-reactive IgM cases. The calculated specificity for the VirClia IgM was 95.8% (95% CI, 92.5-98.0). In conclusion, the sensitivity of the VirClia IgM was non-inferior to the ReaScan TBE IgM rapid test. However, isolated IgM reactive results must be interpreted with caution, since false-reactive results occur.</p>\",\"PeriodicalId\":49328,\"journal\":{\"name\":\"Viruses-Basel\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11437423/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Viruses-Basel\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/v16091505\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VIROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Viruses-Basel","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/v16091505","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VIROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估 VirClia IgM/IgG 单检测化学发光试验在挪威蜱媒脑炎(TBE)流行地区诊断中的临床实用性。研究纳入了 2021 年 5 月至 2023 年 12 月期间在 Vestfold 或 Telemark 医院住院并疑似感染中枢神经系统 (CNS) 的患者,共发现 85 例 TBE 病例。在 75/85 个病例的初始血清样本中,VirClia IgM 检测呈阳性,灵敏度为 88.2%(95% CI,79.4-94.2)。ReaScan TBE IgM 快速检测法在 80/85 个病例中呈阳性,灵敏度估计为 94.1%(95% CI,86.8-98.1)。疫苗破损感染是导致 IgM 未反应病例的主要原因。计算得出的病毒凝集素 IgM 特异性为 95.8%(95% CI,92.5-98.0)。总之,VirClia IgM 的灵敏度并不比 ReaScan TBE IgM 快速检测低。然而,由于会出现假反应结果,因此必须谨慎解释单独的 IgM 反应结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical Evaluation of the VirClia IgM/IgG Chemiluminescence Tests for the Diagnosis of Tick-Borne Encephalitis in an Endemic Part of Norway.

The aim of this study was to evaluate the clinical usefulness of VirClia IgM/IgG single-assay chemiluminescence tests for the diagnosis of tick-borne encephalitis (TBE) in an endemic part of Norway. Patients hospitalized at Vestfold or Telemark Hospitals with suspected infection in the central nervous system (CNS) in the period between May 2021 and December 2023 were included, with 85 TBE cases identified. The VirClia IgM assay was positive in the initial serum sample in 75/85 cases, giving a sensitivity of 88.2% (95% CI, 79.4-94.2). The ReaScan TBE IgM rapid test was positive in 80/85 cases, with an estimated sensitivity of 94.1% (95% CI, 86.8-98.1). Vaccine breakthrough infections were the predominant cause of non-reactive IgM cases. The calculated specificity for the VirClia IgM was 95.8% (95% CI, 92.5-98.0). In conclusion, the sensitivity of the VirClia IgM was non-inferior to the ReaScan TBE IgM rapid test. However, isolated IgM reactive results must be interpreted with caution, since false-reactive results occur.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Viruses-Basel
Viruses-Basel VIROLOGY-
CiteScore
7.30
自引率
12.80%
发文量
2445
审稿时长
1 months
期刊介绍: Viruses (ISSN 1999-4915) is an open access journal which provides an advanced forum for studies of viruses. It publishes reviews, regular research papers, communications, conference reports and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. We also encourage the publication of timely reviews and commentaries on topics of interest to the virology community and feature highlights from the virology literature in the ''News and Views'' section. Electronic files or software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
期刊最新文献
Putting a Kink in HIV-1 Particle Infectivity: Rocaglamide Inhibits HIV-1 Replication by Altering Gag-Genomic RNA Interaction. Clinical Evaluation of the VirClia IgM/IgG Chemiluminescence Tests for the Diagnosis of Tick-Borne Encephalitis in an Endemic Part of Norway. The Omicron Variant Is Associated with a Reduced Risk of the Post COVID-19 Condition and Its Main Phenotypes Compared to the Wild-Type Virus: Results from the EuCARE-POSTCOVID-19 Study. Unleashing Nature's Allies: Comparing the Vertical Transmission Dynamics of Insect-Specific and Vertebrate-Infecting Flaviviruses in Mosquitoes. Zooming in and out: Exploring RNA Viral Infections with Multiscale Microscopic Methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1