使用锥束计算机断层扫描和动态功能分析对正畸患者的颞下颌关节形态和位置进行相关分析:横断面研究。

IF 2.6 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Korean Journal of Orthodontics Pub Date : 2024-09-25 Epub Date: 2024-09-04 DOI:10.4041/kjod24.089
Bin Xu, Jung-Jin Park, Seong-Hun Kim
{"title":"使用锥束计算机断层扫描和动态功能分析对正畸患者的颞下颌关节形态和位置进行相关分析:横断面研究。","authors":"Bin Xu, Jung-Jin Park, Seong-Hun Kim","doi":"10.4041/kjod24.089","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To correlate temporomandibular joint (TMJ) morphology and position with cone-beam computed tomography (CBCT) images, Joint Vibration Analysis (JVA), and Jaw Tracker (JT) to develop a radiation-free, dynamic method for screening and monitoring the TMJ in orthodontic patients.</p><p><strong>Methods: </strong>A total of 236 orthodontic patients without symptoms of TMJ disorders who had undergone CBCT were selected for the JVA and JT tests in this cross-sectional study. TMJ position and morphology were measured using a three-dimensional analysis software. JT measurements involved six opening-closing cycles, and JVA measurements were performed using a metronome to guide the mouth opening-closing movements of the patients. The correlations among the three measuring devices were evaluated.</p><p><strong>Results: </strong>Abnormalities in condylar surface morphology affected the mandibular range of motion. The cut-off value results show that when various measurement groups are within a certain range, abnormalities may be observed in morphology (area under the curve, 0.81; <i>P</i> < 0.001). A 300/< 300 Hz ratio ≥ 0.09 suggested abnormal morphology (<i>P</i> < 0.05). Correlations were observed among the maximum opening velocity, maximum vertical opening position, and joint spaces in the JT measurements. Correlations were also observed between the > 300/< 300 Hz ratio, median frequency, total integral, integral < 300 Hz, and peak frequency with joint spaces in the JVA measurements.</p><p><strong>Conclusions: </strong>JT and JVA may serve as rapid, non-invasive, and radiation-free dynamic diagnostic tools for monitoring and screening TMJ abnormalities before and during orthodontic treatment.</p>","PeriodicalId":51260,"journal":{"name":"Korean Journal of Orthodontics","volume":"54 5","pages":"325-341"},"PeriodicalIF":2.6000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11422681/pdf/","citationCount":"0","resultStr":"{\"title\":\"Correlations of temporomandibular joint morphology and position using cone-beam computed tomography and dynamic functional analysis in orthodontic patients: A cross-sectional study.\",\"authors\":\"Bin Xu, Jung-Jin Park, Seong-Hun Kim\",\"doi\":\"10.4041/kjod24.089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To correlate temporomandibular joint (TMJ) morphology and position with cone-beam computed tomography (CBCT) images, Joint Vibration Analysis (JVA), and Jaw Tracker (JT) to develop a radiation-free, dynamic method for screening and monitoring the TMJ in orthodontic patients.</p><p><strong>Methods: </strong>A total of 236 orthodontic patients without symptoms of TMJ disorders who had undergone CBCT were selected for the JVA and JT tests in this cross-sectional study. TMJ position and morphology were measured using a three-dimensional analysis software. JT measurements involved six opening-closing cycles, and JVA measurements were performed using a metronome to guide the mouth opening-closing movements of the patients. The correlations among the three measuring devices were evaluated.</p><p><strong>Results: </strong>Abnormalities in condylar surface morphology affected the mandibular range of motion. The cut-off value results show that when various measurement groups are within a certain range, abnormalities may be observed in morphology (area under the curve, 0.81; <i>P</i> < 0.001). A 300/< 300 Hz ratio ≥ 0.09 suggested abnormal morphology (<i>P</i> < 0.05). Correlations were observed among the maximum opening velocity, maximum vertical opening position, and joint spaces in the JT measurements. Correlations were also observed between the > 300/< 300 Hz ratio, median frequency, total integral, integral < 300 Hz, and peak frequency with joint spaces in the JVA measurements.</p><p><strong>Conclusions: </strong>JT and JVA may serve as rapid, non-invasive, and radiation-free dynamic diagnostic tools for monitoring and screening TMJ abnormalities before and during orthodontic treatment.</p>\",\"PeriodicalId\":51260,\"journal\":{\"name\":\"Korean Journal of Orthodontics\",\"volume\":\"54 5\",\"pages\":\"325-341\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11422681/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Orthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4041/kjod24.089\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4041/kjod24.089","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的将颞下颌关节(TMJ)的形态和位置与锥形束计算机断层扫描(CBCT)图像、关节振动分析(JVA)和下颌追踪器(JT)相关联,以开发一种无辐射的动态方法,用于筛查和监测正畸患者的颞下颌关节:在这项横断面研究中,共选取了 236 名接受过 CBCT 检查且无颞下颌关节紊乱症状的正畸患者进行 JVA 和 JT 测试。使用三维分析软件测量颞下颌关节的位置和形态。JT 测量包括六个张合周期,而 JVA 测量则使用节拍器引导患者的张合运动。对三种测量设备之间的相关性进行了评估:结果:髁突表面形态异常会影响下颌骨的活动范围。截断值结果显示,当各测量组在一定范围内时,可观察到形态异常(曲线下面积,0.81;P < 0.001)。300/< 300 Hz 比值≥ 0.09 提示形态异常(P < 0.05)。在 JT 测量中,最大张开速度、最大垂直张开位置和关节间隙之间存在相关性。在 JVA 测量中,> 300/< 300 Hz 比率、中位频率、总积分、积分 < 300 Hz 和峰值频率与关节间隙之间也存在相关性:JT和JVA可作为快速、无创、无辐射的动态诊断工具,在正畸治疗前和治疗过程中监测和筛查颞下颌关节异常。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Correlations of temporomandibular joint morphology and position using cone-beam computed tomography and dynamic functional analysis in orthodontic patients: A cross-sectional study.

Objective: To correlate temporomandibular joint (TMJ) morphology and position with cone-beam computed tomography (CBCT) images, Joint Vibration Analysis (JVA), and Jaw Tracker (JT) to develop a radiation-free, dynamic method for screening and monitoring the TMJ in orthodontic patients.

Methods: A total of 236 orthodontic patients without symptoms of TMJ disorders who had undergone CBCT were selected for the JVA and JT tests in this cross-sectional study. TMJ position and morphology were measured using a three-dimensional analysis software. JT measurements involved six opening-closing cycles, and JVA measurements were performed using a metronome to guide the mouth opening-closing movements of the patients. The correlations among the three measuring devices were evaluated.

Results: Abnormalities in condylar surface morphology affected the mandibular range of motion. The cut-off value results show that when various measurement groups are within a certain range, abnormalities may be observed in morphology (area under the curve, 0.81; P < 0.001). A 300/< 300 Hz ratio ≥ 0.09 suggested abnormal morphology (P < 0.05). Correlations were observed among the maximum opening velocity, maximum vertical opening position, and joint spaces in the JT measurements. Correlations were also observed between the > 300/< 300 Hz ratio, median frequency, total integral, integral < 300 Hz, and peak frequency with joint spaces in the JVA measurements.

Conclusions: JT and JVA may serve as rapid, non-invasive, and radiation-free dynamic diagnostic tools for monitoring and screening TMJ abnormalities before and during orthodontic treatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Orthodontics
Korean Journal of Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.50
自引率
10.50%
发文量
48
审稿时长
>12 weeks
期刊介绍: The Korean Journal of Orthodontics (KJO) is an international, open access, peer reviewed journal published in January, March, May, July, September, and November each year. It was first launched in 1970 and, as the official scientific publication of Korean Association of Orthodontists, KJO aims to publish high quality clinical and scientific original research papers in all areas related to orthodontics and dentofacial orthopedics. Specifically, its interest focuses on evidence-based investigations of contemporary diagnostic procedures and treatment techniques, expanding to significant clinical reports of diverse treatment approaches. The scope of KJO covers all areas of orthodontics and dentofacial orthopedics including successful diagnostic procedures and treatment planning, growth and development of the face and its clinical implications, appliance designs, biomechanics, TMJ disorders and adult treatment. Specifically, its latest interest focuses on skeletal anchorage devices, orthodontic appliance and biomaterials, 3 dimensional imaging techniques utilized for dentofacial diagnosis and treatment planning, and orthognathic surgery to correct skeletal disharmony in association of orthodontic treatment.
期刊最新文献
Effect of bone-borne maxillary skeletal expanders on cranial and circummaxillary sutures: A cone-beam computed tomography study. Finite element analysis of the effects of different archwire forms and power arm positions on maxillary incisors in en masse retraction using fixed lingual orthodontic appliances. Upper airway dimensions and craniofacial morphology: A correlation study using cone beam computed tomography. Genetic polymorphisms in external apical root resorption and orthodontic tooth movements: A systematic review. Dentoalveolar effects of open-bite correction with the dual action vertical intra-arch technique: A finite element analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1