{"title":"黄斑孔手术与视网膜构造:内限制膜剥离尺寸对视网膜切向位移的影响","authors":"Marco Pellegrini, Ginevra Adamo, Chiara Vivarelli, Alice Bizzarri, Riccardo Mondin, Pietro Maria Talli, Francesco Nasini, Giuseppe Giannaccare, Marco Mura","doi":"10.1097/IAE.0000000000004276","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the study was to evaluate the tangential retinal displacement occurring following macular hole surgery, and to assess the impact of the internal limiting membrane (ILM) peeling size on the extent of the retinal movement.</p><p><strong>Methods: </strong>This retrospective study included patients with full-thickness macular hole undergoing 25-gauge pars plana vitrectomy with ILM peeling. Patients received either a small ILM peeling with a size of 2-disc diameters or a large peeling extended up to the vascular arcades. Near-infrared retinal imaging was performed with the Spectralis (Heidelberg Engineering, Carlsbad, Germany) before and 6 months after surgery. The tangential retinal displacement was evaluated comparing the optical flow of near-infrared images with a custom digital image analysis algorithm.</p><p><strong>Results: </strong>44 eyes of 44 patients undergoing vitrectomy with small (n = 24) or large (n = 20) ILM peeling were included. An average overall displacement of 31.3 ± 22.8 µm towards the optic disc was observed after surgery. Large ILM peeling was associated with a significantly higher overall displacement (P = 0.009), displacement in the central 4-mm circle (P < 0.001) and outer 8-mm ring (P = 0.001). Macular holes closure was achieved in 100% and 83.3% of patients in the large and small peeling group, respectively (P = 0.055).</p><p><strong>Conclusions: </strong>Pars plana vitrectomy with ILM peeling for macular hole results in a tangential retinal displacement towards the optic disc. A larger extent of the ILM peeling leads to a greater tangential movement, possibly improving the macular hole closure rate.</p>","PeriodicalId":54486,"journal":{"name":"Retina-The Journal of Retinal and Vitreous Diseases","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Macular Hole Surgery and Retinal Tectonics: The Impact of Internal Limiting Membrane Peeling Size on Tangential Retinal Displacement.\",\"authors\":\"Marco Pellegrini, Ginevra Adamo, Chiara Vivarelli, Alice Bizzarri, Riccardo Mondin, Pietro Maria Talli, Francesco Nasini, Giuseppe Giannaccare, Marco Mura\",\"doi\":\"10.1097/IAE.0000000000004276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of the study was to evaluate the tangential retinal displacement occurring following macular hole surgery, and to assess the impact of the internal limiting membrane (ILM) peeling size on the extent of the retinal movement.</p><p><strong>Methods: </strong>This retrospective study included patients with full-thickness macular hole undergoing 25-gauge pars plana vitrectomy with ILM peeling. Patients received either a small ILM peeling with a size of 2-disc diameters or a large peeling extended up to the vascular arcades. Near-infrared retinal imaging was performed with the Spectralis (Heidelberg Engineering, Carlsbad, Germany) before and 6 months after surgery. The tangential retinal displacement was evaluated comparing the optical flow of near-infrared images with a custom digital image analysis algorithm.</p><p><strong>Results: </strong>44 eyes of 44 patients undergoing vitrectomy with small (n = 24) or large (n = 20) ILM peeling were included. An average overall displacement of 31.3 ± 22.8 µm towards the optic disc was observed after surgery. Large ILM peeling was associated with a significantly higher overall displacement (P = 0.009), displacement in the central 4-mm circle (P < 0.001) and outer 8-mm ring (P = 0.001). Macular holes closure was achieved in 100% and 83.3% of patients in the large and small peeling group, respectively (P = 0.055).</p><p><strong>Conclusions: </strong>Pars plana vitrectomy with ILM peeling for macular hole results in a tangential retinal displacement towards the optic disc. A larger extent of the ILM peeling leads to a greater tangential movement, possibly improving the macular hole closure rate.</p>\",\"PeriodicalId\":54486,\"journal\":{\"name\":\"Retina-The Journal of Retinal and Vitreous Diseases\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Retina-The Journal of Retinal and Vitreous Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/IAE.0000000000004276\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retina-The Journal of Retinal and Vitreous Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IAE.0000000000004276","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:该研究旨在评估黄斑孔手术后发生的切向视网膜移位,并评估内限制膜(ILM)剥离大小对视网膜移动程度的影响:这项回顾性研究纳入了接受25号镜玻璃体旁切除术和ILM剥离术的全厚黄斑孔患者。患者要么接受了2盘直径大小的小ILM剥离,要么接受了延伸至血管弧的大剥离。手术前和手术后6个月,使用Spectralis(海德堡工程公司,德国卡尔斯巴德)进行了近红外视网膜成像。通过定制的数字图像分析算法,比较近红外图像的光流,对视网膜切向位移进行评估:结果:44 位患者的 44 只眼睛接受了玻璃体切除术,其中有小面积(24 只)或大面积(20 只)ILM 剥离。术后观察到向视盘方向的平均整体位移为 31.3 ± 22.8 µm。大面积ILM剥离与总体位移(P = 0.009)、中央4毫米圈(P < 0.001)和外部8毫米圈(P = 0.001)的位移显著增加有关。大剥离组和小剥离组分别有100%和83.3%的患者实现了黄斑孔闭合(P = 0.055):结论:平面玻璃体旁切除并剥离ILM治疗黄斑孔会导致视网膜切向移位至视盘。ILM剥离范围越大,切向移动越大,可能会提高黄斑孔的闭合率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Macular Hole Surgery and Retinal Tectonics: The Impact of Internal Limiting Membrane Peeling Size on Tangential Retinal Displacement.

Purpose: The aim of the study was to evaluate the tangential retinal displacement occurring following macular hole surgery, and to assess the impact of the internal limiting membrane (ILM) peeling size on the extent of the retinal movement.

Methods: This retrospective study included patients with full-thickness macular hole undergoing 25-gauge pars plana vitrectomy with ILM peeling. Patients received either a small ILM peeling with a size of 2-disc diameters or a large peeling extended up to the vascular arcades. Near-infrared retinal imaging was performed with the Spectralis (Heidelberg Engineering, Carlsbad, Germany) before and 6 months after surgery. The tangential retinal displacement was evaluated comparing the optical flow of near-infrared images with a custom digital image analysis algorithm.

Results: 44 eyes of 44 patients undergoing vitrectomy with small (n = 24) or large (n = 20) ILM peeling were included. An average overall displacement of 31.3 ± 22.8 µm towards the optic disc was observed after surgery. Large ILM peeling was associated with a significantly higher overall displacement (P = 0.009), displacement in the central 4-mm circle (P < 0.001) and outer 8-mm ring (P = 0.001). Macular holes closure was achieved in 100% and 83.3% of patients in the large and small peeling group, respectively (P = 0.055).

Conclusions: Pars plana vitrectomy with ILM peeling for macular hole results in a tangential retinal displacement towards the optic disc. A larger extent of the ILM peeling leads to a greater tangential movement, possibly improving the macular hole closure rate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.70
自引率
9.10%
发文量
554
审稿时长
3-6 weeks
期刊介绍: ​RETINA® focuses exclusively on the growing specialty of vitreoretinal disorders. The Journal provides current information on diagnostic and therapeutic techniques. Its highly specialized and informative, peer-reviewed articles are easily applicable to clinical practice. In addition to regular reports from clinical and basic science investigators, RETINA® publishes special features including periodic review articles on pertinent topics, special articles dealing with surgical and other therapeutic techniques, and abstract cards. Issues are abundantly illustrated in vivid full color. Published 12 times per year, RETINA® is truly a “must have” publication for anyone connected to this field.
期刊最新文献
Surgical outcomes of tractional maculopathy associated with familial exudative vitreoretinopathy in children. Four-year outcomes after intravitreal aflibercept for macular neovascularization in patients with pathologic myopia. Real-World Long-Term Outcomes of Intravitreal Faricimab in Previously Treated Chronic Neovascular Age-Related Macular Degeneration. A Modified Girth-Hitch Suture Technique to Rescue Single-Haptic Dislocation of Scleral-Fixated Intraocular Lenses. SHORT-TERM REACTIVATION OF RETINOPATHY OF PREMATURITY AFTER PRIMARY RANIBIZUMAB TREATMENT.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1