使用氧化锆、钢或钴铬股骨头的骨水泥全髋关节置换术的聚乙烯磨损和髋臼杯移位:使用放射线测量法对随机试验进行的为期 10 年的二次分析。

IF 2.5 2区 医学 Q1 ORTHOPEDICS Acta Orthopaedica Pub Date : 2024-09-30 DOI:10.2340/17453674.2024.41945
Håkon Greve Johannessen, Geir Hallan, Thomas Kadar, Anne Marie Fenstad, Stein Håkon Låstad Lygre, Kristin Haugan, Paul Johan Høl, Mona Badawy, Benedikt Jonsson, Kari Indrekvam, Arild Aamodt, Ove Furnes
{"title":"使用氧化锆、钢或钴铬股骨头的骨水泥全髋关节置换术的聚乙烯磨损和髋臼杯移位:使用放射线测量法对随机试验进行的为期 10 年的二次分析。","authors":"Håkon Greve Johannessen, Geir Hallan, Thomas Kadar, Anne Marie Fenstad, Stein Håkon Låstad Lygre, Kristin Haugan, Paul Johan Høl, Mona Badawy, Benedikt Jonsson, Kari Indrekvam, Arild Aamodt, Ove Furnes","doi":"10.2340/17453674.2024.41945","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>We aimed to evaluate polyethylene (PE) wear, cup migration, and clinical outcome over 10 years in total hip arthroplasties (THA) using different articulations.</p><p><strong>Methods: </strong> This is a secondary analysis of 150 patients randomized into 5 groups, using different articulations: Charnley/Charnley Ogee for steel and conventional polyethylene (CPE), or Spectron EF/Reflection with either CPE or highly cross linked polyethylene (XLPE) cups, paired with heads made of either cobalt-chromium (CoCr) or oxidized zirconium (OxZr). All cups were cemented. Patients underwent repeated radiostereometric analysis (RSA) measurements for up to 10 years to assess wear and migration. Clinical outcome was assessed using Harris Hip Score (HHS).</p><p><strong>Results: </strong> After 10 years, the XLPE cups demonstrated low wear rates: 0.08 mm (95% confidence interval [CI] -0.11 to 0.26 mm) with CoCr heads and 0.06 mm (CI -0.14 to 0.26 mm) with OxZr heads, with a mean difference of 0.01 mm (CI -0.26 to 0.29 mm). In contrast, CPE cups exhibited significantly more wear: 1.35 mm (CI 1.16 to 1.55 mm) with CoCr heads and 1.68 mm (CI 1.44 to 1.92 mm) with OxZr heads, with a mean difference of 0.33 mm (CI 0.02 to 0.64 mm). The Charnley/Ogee group (CPE) showed PE wear of 0.34 mm (CI 0.12 to 0.56 mm). The CPE groups with OxZr and CoCr heads had 0.67 mm (CI 0.38 to 0.96 mm) and 0.35 mm (CI 0.09 to 0.61 mm) greater proximal migration respectively than the corresponding XLPE groups. HHS was similar across all groups.</p><p><strong>Conclusion: </strong> We found no significant advantage of OxZr over CoCr heads in reducing wear or migration. XLPE demonstrated a major reduction in wear as well as a reduction in cup migration compared with CPE. Charnley performed better than the other CPE cups in terms of PE wear and cup migration. No differences in clinical outcome were found.</p>","PeriodicalId":6916,"journal":{"name":"Acta Orthopaedica","volume":"95 ","pages":"578-585"},"PeriodicalIF":2.5000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11441331/pdf/","citationCount":"0","resultStr":"{\"title\":\"Polyethylene wear and cup migration of cemented total hip arthroplasty with femoral heads made of oxidized zirconium, steel, or cobalt chromium: a 10-year secondary analysis from a randomized trial using radiostereometry.\",\"authors\":\"Håkon Greve Johannessen, Geir Hallan, Thomas Kadar, Anne Marie Fenstad, Stein Håkon Låstad Lygre, Kristin Haugan, Paul Johan Høl, Mona Badawy, Benedikt Jonsson, Kari Indrekvam, Arild Aamodt, Ove Furnes\",\"doi\":\"10.2340/17453674.2024.41945\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and purpose: </strong>We aimed to evaluate polyethylene (PE) wear, cup migration, and clinical outcome over 10 years in total hip arthroplasties (THA) using different articulations.</p><p><strong>Methods: </strong> This is a secondary analysis of 150 patients randomized into 5 groups, using different articulations: Charnley/Charnley Ogee for steel and conventional polyethylene (CPE), or Spectron EF/Reflection with either CPE or highly cross linked polyethylene (XLPE) cups, paired with heads made of either cobalt-chromium (CoCr) or oxidized zirconium (OxZr). All cups were cemented. Patients underwent repeated radiostereometric analysis (RSA) measurements for up to 10 years to assess wear and migration. Clinical outcome was assessed using Harris Hip Score (HHS).</p><p><strong>Results: </strong> After 10 years, the XLPE cups demonstrated low wear rates: 0.08 mm (95% confidence interval [CI] -0.11 to 0.26 mm) with CoCr heads and 0.06 mm (CI -0.14 to 0.26 mm) with OxZr heads, with a mean difference of 0.01 mm (CI -0.26 to 0.29 mm). In contrast, CPE cups exhibited significantly more wear: 1.35 mm (CI 1.16 to 1.55 mm) with CoCr heads and 1.68 mm (CI 1.44 to 1.92 mm) with OxZr heads, with a mean difference of 0.33 mm (CI 0.02 to 0.64 mm). The Charnley/Ogee group (CPE) showed PE wear of 0.34 mm (CI 0.12 to 0.56 mm). The CPE groups with OxZr and CoCr heads had 0.67 mm (CI 0.38 to 0.96 mm) and 0.35 mm (CI 0.09 to 0.61 mm) greater proximal migration respectively than the corresponding XLPE groups. HHS was similar across all groups.</p><p><strong>Conclusion: </strong> We found no significant advantage of OxZr over CoCr heads in reducing wear or migration. XLPE demonstrated a major reduction in wear as well as a reduction in cup migration compared with CPE. Charnley performed better than the other CPE cups in terms of PE wear and cup migration. No differences in clinical outcome were found.</p>\",\"PeriodicalId\":6916,\"journal\":{\"name\":\"Acta Orthopaedica\",\"volume\":\"95 \",\"pages\":\"578-585\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11441331/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Orthopaedica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2340/17453674.2024.41945\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Orthopaedica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/17453674.2024.41945","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:我们的目的是评估使用不同关节的全髋关节置换术(THA)10年来的聚乙烯(PE)磨损、髋臼杯移位和临床疗效: 这是对随机分为5组、采用不同关节的150名患者进行的二次分析:方法:这是对150名患者进行的二次分析,随机分为5组,采用不同的关节连接方式:钢和传统聚乙烯(CPE)的Charnley/Charnley Ogee,或使用CPE或高交联聚乙烯(XLPE)髋臼杯的Spectron EF/Reflection,配以钴铬(CoCr)或氧化锆(OxZr)制成的髋臼头。所有髋臼杯均采用骨水泥固定。患者在长达10年的时间里反复接受放射性立体计量分析(RSA)测量,以评估磨损和移位情况。临床结果采用哈里斯髋关节评分(HHS)进行评估: 10年后,XLPE髋臼杯的磨损率很低,仅为0.08毫米(95%置信区间):结果:10年后,XLPE髋臼杯的磨损率较低:钴铬合金头为0.08毫米(95%置信区间[CI]-0.11至0.26毫米),OxZr头为0.06毫米(CI-0.14至0.26毫米),平均差异为0.01毫米(CI-0.26至0.29毫米)。相比之下,CPE髋臼杯的磨损明显更严重:钴铬合金头磨损1.35毫米(CI值为1.16至1.55毫米),OxZr头磨损1.68毫米(CI值为1.44至1.92毫米),平均差异为0.33毫米(CI值为0.02至0.64毫米)。Charnley/Ogee组(CPE)的PE磨损为0.34毫米(CI为0.12至0.56毫米)。与相应的 XLPE 组相比,带有 OxZr 和 CoCr 头的 CPE 组的近端移位分别大 0.67 毫米(CI 0.38 至 0.96 毫米)和 0.35 毫米(CI 0.09 至 0.61 毫米)。各组的 HHS 相似: 我们发现,与钴铬合金头相比,OxZr在减少磨损或移位方面没有明显优势。与 CPE 相比,XLPE 在减少磨损和减少髋臼杯移位方面表现突出。在PE磨损和杯体移位方面,Charnley比其他CPE杯表现更好。在临床结果方面没有发现差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Polyethylene wear and cup migration of cemented total hip arthroplasty with femoral heads made of oxidized zirconium, steel, or cobalt chromium: a 10-year secondary analysis from a randomized trial using radiostereometry.

Background and purpose: We aimed to evaluate polyethylene (PE) wear, cup migration, and clinical outcome over 10 years in total hip arthroplasties (THA) using different articulations.

Methods:  This is a secondary analysis of 150 patients randomized into 5 groups, using different articulations: Charnley/Charnley Ogee for steel and conventional polyethylene (CPE), or Spectron EF/Reflection with either CPE or highly cross linked polyethylene (XLPE) cups, paired with heads made of either cobalt-chromium (CoCr) or oxidized zirconium (OxZr). All cups were cemented. Patients underwent repeated radiostereometric analysis (RSA) measurements for up to 10 years to assess wear and migration. Clinical outcome was assessed using Harris Hip Score (HHS).

Results:  After 10 years, the XLPE cups demonstrated low wear rates: 0.08 mm (95% confidence interval [CI] -0.11 to 0.26 mm) with CoCr heads and 0.06 mm (CI -0.14 to 0.26 mm) with OxZr heads, with a mean difference of 0.01 mm (CI -0.26 to 0.29 mm). In contrast, CPE cups exhibited significantly more wear: 1.35 mm (CI 1.16 to 1.55 mm) with CoCr heads and 1.68 mm (CI 1.44 to 1.92 mm) with OxZr heads, with a mean difference of 0.33 mm (CI 0.02 to 0.64 mm). The Charnley/Ogee group (CPE) showed PE wear of 0.34 mm (CI 0.12 to 0.56 mm). The CPE groups with OxZr and CoCr heads had 0.67 mm (CI 0.38 to 0.96 mm) and 0.35 mm (CI 0.09 to 0.61 mm) greater proximal migration respectively than the corresponding XLPE groups. HHS was similar across all groups.

Conclusion:  We found no significant advantage of OxZr over CoCr heads in reducing wear or migration. XLPE demonstrated a major reduction in wear as well as a reduction in cup migration compared with CPE. Charnley performed better than the other CPE cups in terms of PE wear and cup migration. No differences in clinical outcome were found.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Orthopaedica
Acta Orthopaedica 医学-整形外科
CiteScore
6.40
自引率
8.10%
发文量
105
审稿时长
4-8 weeks
期刊介绍: Acta Orthopaedica (previously Acta Orthopaedica Scandinavica) presents original articles of basic research interest, as well as clinical studies in the field of orthopedics and related sub disciplines. Ever since the journal was founded in 1930, by a group of Scandinavian orthopedic surgeons, the journal has been published for an international audience. Acta Orthopaedica is owned by the Nordic Orthopaedic Federation and is the official publication of this federation.
期刊最新文献
Acute treatment of elderly patients with acetabular fractures by open reduction, internal fixation, and total hip arthroplasty: a 1-10-year follow-up of 48 patients. Incidence and risk factors of adverse events after distal radius fracture fixation with volar locking plates: retrospective analysis of 2,790 cases. The completeness of national hip and knee replacement registers. Can KOOS-PS be replaced with a simple anchor question in patients after total knee arthroplasty?: an agreement study of 2,478 primary surgeries. Erratum: Regional variation in low-value musculoskeletal surgery: a nationwide study from the Finnish Care Register.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1