Chen Yang, Yang Liu, Yu Mao, Xiaoke Shang, Fan Qiao, Jian Liu, Yenong Zhou, Mengen Zhai, Shiqiang Yu, Tao Chen, Jian Yang, Zhenxiao Jin
{"title":"机械循环支持对经导管主动脉瓣置换术后死亡率的影响:里程碑式的分析","authors":"Chen Yang, Yang Liu, Yu Mao, Xiaoke Shang, Fan Qiao, Jian Liu, Yenong Zhou, Mengen Zhai, Shiqiang Yu, Tao Chen, Jian Yang, Zhenxiao Jin","doi":"10.1097/MAT.0000000000002313","DOIUrl":null,"url":null,"abstract":"<p><p>A proportion of patients still need mechanical circulatory support (MCS) during the transcatheter aortic valve replacement (TAVR) because of intraoperative hemodynamic instability. However, the outcomes of patients with different MCS type during TAVR are still controversial. A total of 538 patients who underwent TAVR procedure in four centers were included. The time-related outcomes and their predictors of patients who did not have MCS (MCS-, n = 498) were compared with those who underwent emergency MCS (eMCS+, n = 18) and prophylactic MCS (pMCS+, n = 22). We evaluated the association between different MCS groups and all-cause mortality using conditional landmark analysis with Cox regression. There was a significant increase in 30-day mortality in the eMCS+ group (plog-rank < 0.001) and no significant difference in 31-day to 1-year mortality among the groups (plog-rank = 0.789). A significant improvement in the left ventricular ejection fraction was observed in the pMCS+ group at 1 year after TAVR. Emergency MCS was independently associated with 30-day mortality, as well as 1-year mortality. Prophylactic MCS showed good clinical outcomes and might be considered for high-risk patients. Further studies are needed to investigate the predictors that lead to MCS usage and long-term mortality in TAVR patients with MCS.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Mechanical Circulatory Support on Mortality After Transcatheter Aortic Valve Replacement: A Landmark Analysis.\",\"authors\":\"Chen Yang, Yang Liu, Yu Mao, Xiaoke Shang, Fan Qiao, Jian Liu, Yenong Zhou, Mengen Zhai, Shiqiang Yu, Tao Chen, Jian Yang, Zhenxiao Jin\",\"doi\":\"10.1097/MAT.0000000000002313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A proportion of patients still need mechanical circulatory support (MCS) during the transcatheter aortic valve replacement (TAVR) because of intraoperative hemodynamic instability. However, the outcomes of patients with different MCS type during TAVR are still controversial. A total of 538 patients who underwent TAVR procedure in four centers were included. The time-related outcomes and their predictors of patients who did not have MCS (MCS-, n = 498) were compared with those who underwent emergency MCS (eMCS+, n = 18) and prophylactic MCS (pMCS+, n = 22). We evaluated the association between different MCS groups and all-cause mortality using conditional landmark analysis with Cox regression. There was a significant increase in 30-day mortality in the eMCS+ group (plog-rank < 0.001) and no significant difference in 31-day to 1-year mortality among the groups (plog-rank = 0.789). A significant improvement in the left ventricular ejection fraction was observed in the pMCS+ group at 1 year after TAVR. Emergency MCS was independently associated with 30-day mortality, as well as 1-year mortality. Prophylactic MCS showed good clinical outcomes and might be considered for high-risk patients. Further studies are needed to investigate the predictors that lead to MCS usage and long-term mortality in TAVR patients with MCS.</p>\",\"PeriodicalId\":8844,\"journal\":{\"name\":\"ASAIO Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASAIO Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1097/MAT.0000000000002313\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002313","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Effect of Mechanical Circulatory Support on Mortality After Transcatheter Aortic Valve Replacement: A Landmark Analysis.
A proportion of patients still need mechanical circulatory support (MCS) during the transcatheter aortic valve replacement (TAVR) because of intraoperative hemodynamic instability. However, the outcomes of patients with different MCS type during TAVR are still controversial. A total of 538 patients who underwent TAVR procedure in four centers were included. The time-related outcomes and their predictors of patients who did not have MCS (MCS-, n = 498) were compared with those who underwent emergency MCS (eMCS+, n = 18) and prophylactic MCS (pMCS+, n = 22). We evaluated the association between different MCS groups and all-cause mortality using conditional landmark analysis with Cox regression. There was a significant increase in 30-day mortality in the eMCS+ group (plog-rank < 0.001) and no significant difference in 31-day to 1-year mortality among the groups (plog-rank = 0.789). A significant improvement in the left ventricular ejection fraction was observed in the pMCS+ group at 1 year after TAVR. Emergency MCS was independently associated with 30-day mortality, as well as 1-year mortality. Prophylactic MCS showed good clinical outcomes and might be considered for high-risk patients. Further studies are needed to investigate the predictors that lead to MCS usage and long-term mortality in TAVR patients with MCS.
期刊介绍:
ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world.
The official publication of the American Society for Artificial Internal Organs.